SEALEY-LOGO

SEALEY AB2050 Space Warmer Kerosene Diesel Heater

SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-PRODUCT

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

  • Refer to instructions
  • Warning! automatic start-up
  • Warning! Hot surfaces
  • Warning!

SAFETY

ELECTRICAL SAFETY

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You must also read and understand the following instructions concerning electrical safety. Ensure that cables are always protected against short circuit and overload. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating at right.
DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
replaced immediately by a competent electrician.
It is recommended that this heater is wired directly to a fused isolator switch. If, however, a plug
is fitted, the following applies:
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable restraint is tight.SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-1

GENERAL SAFETY

Read instructions carefully. Read and follow all instructions. Place instructions in a safe place for future reference.
DO NOT allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
9 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss
of life.

Check that the heater is in sound condition and good working order. Servicing must be performed by qualified operatives only.
Take immediate action to repair or replace damaged parts. Use recommended parts only. Unapproved parts may be dangerous and
will invalidate the warranty. Only use clean kerosene orCheck that the heater is in sound condition and good working order. Servicing must be performed by qualified operatives only. Take immediate action to repair or replace damaged parts. Use recommended parts only. Unapproved parts may be dangerous and
will invalidate the warranty.

Only use clean kerosene or diesel (NOT BIO-DIESEL) to fuel your heater, in accordance with instructions contained in this manual. WARNING! Only use heater in well ventilated areas. Ensure continuous ventilation from outside of the building is provided to the heater operating area. Refer to 5.2 Installation Maximum Opening Size. Unvented portable heaters use air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided.  DO NOT store or use compressed air cylinders, petrol or other flammable liquids/gases in the vicinity of this or any other appliance.

WARNING! fire, burning and inhalation hazard. Keep solid combustibles such as building materials, paper and cardboard away from the heater. Never use the heater in spaces which do or may contain volatile or airborne products such as petrol, solvents, paint thinner, dust particles or unknown chemicals. Direct fired heaters may cause carbon monoxide (CO) poisoning when incorrectly used e.g. indoors without adequate air circulation, or if not working properly. CO poisoning may lead to death.

  • DO NOT use the heater in closed rooms, living areas, basements or below ground level.
  • DO NOT allow untrained persons to operate the heater and DO NOT operate the heater without the cover.
  • DO NOT move or handle the heater when hot.
  • DO NOT leave the heater unattended when in use. Switch the heater off and unplug from the mains before leaving work area.
  • DO NOT fill the fuel tank whilst the heater is running or still hot.
  • DO NOT overfill the fuel container. Wipe up any spilt fuel immediately.
  • DO NOT obstruct the air inlet (rear) and air outlet (front) of the heater. DO NOT use duct work in front or at the rear of the heater.
  • DO NOT look into the exhaust end of the heater.
  • DO NOT allow children or animals near the heater when in use, or while hot.

WARNING! not for recreational vehicle use.
DANGER! the front outlet is very hot during operation. DO NOT touch danger of burning.
WARNING! RISK OF ELECTRIC SHOCK. DO NOT expose the heater to water spray, rain, dripping water or wind.

DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT touch the heater outlet or dome when first switched off as these are very hot and will take time to cool.
Ensure that the heater is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
DO NOT unplug the heater to switch it off. Use the ON/OFF switch.
WARNING! Improper maintenance can lead to poor combustion and soot production
WARNING! IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER

NOTE: This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

INTRODUCTION

205,000Btu/hr(60kW) Heat output. Clean burning and proven pump system can operate with either kerosene or diesel. Stainless steel combustion chamber. Can be thermostatically controlled to desired temperature. Fitted with safety cut-outs and fuel gauge. Features sturdy handle and heavy-duty wheels for easy manoeuvrability Complies with rigorous standards.

SPECIFICATION

Model no. AB2050
Airflow (cfm) 700
Electrical fuse rating 13A
Electrical Plug type 3-pin BS
Fuel Kerosene/Diesel
Fuel tank 56L
Heated area 56,500ft³(1,600m³)
Motor power 340W
Output 205,000Btu/hr(60kW)
Running time per filling (max.) 10hr
Supply 230V~50Hz
Transport wheels Yes

SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-2

No. Description Qty.
A Handle 1
B Feet pipe 1
C Nut 6 or 8
D Plain washer 6 or 8
E Wheel cap 2
F Wheel 2
G Bush 2
H Wheel shaft 1
I (letter not used)  
J Screw 6 or 8

ASSEMBLY

Insert the wheel shaft H to the corresponding hole of feet pipe B. Fix bush G to the two ends of wheel shaft H, slide the wheel F over the wheel shaft H. Screw on wheel cap E to fix the wheel on the shaft H. Put the heater body on the feet pipe assembly, make sure the 4 holes of handle A point towards the corresponding 4 holes on the feet pipe B respectively. Using the screw J , washer D and nut C to fix the feet pipe assembly and handle to the tank.

INSTALLATION

Position the heater on a flat, level, non-flammable, solid surface. Direct-fired heaters are intended for use in outdoor open areas or in indoor well ventilated areas. For indoor use, provide permanent ventilation openings of at least 25 cm²/kW, equally distributed between floor and high level, with a minimum of 250 cm². Maximum Opening Size: AB2050: 1400cm²

Only install the heater in normal upright position.

  • DO NOT place the heater near walls, corners or low ceilings.
  • DO NOT place the heater below a socket outlet.DO NOT place the heater on moving vehicles or where it can tip over.
  • Keep the heater away from flammable, combustible, explosive or corrosive materials.
  • Keep the heater away from curtains or similar materials that could block the air inlet and outlet.
  • Never block or restrict the air inlet and outlet for any reason
  • Keep the power cable away from heat sources, sharp edges, cutting and moving parts.
  • DO NOT expose directly to the weather or to excessive humidity.
  • DO NOT place the heater in the immediate surroundings of a bath, shower or swimming pool.
  • Follow general and special fire safety regulations in force in all fields of applications. In any case ensure the following minimum safetyclearances from materials or objects in the surroundings of the heater: Side: 0.6 m
  • Air inlet side: 1 m Top: 1.5 m Hot air outlet side: 3 m Floor: 0 m
  • Floors and ceilings must be made of fireproof materials in the place where the heater is operated.8DO NOT connect direct-fired heaters to air ducts

OPERATING CONDITIONS

KEROSENE AND DIESEL FUEL USAGE
These AB heaters are factory adjusted to give the most efficient burn on kerosene but will also burn diesel. Note that kerosene will tend to burn more cleanly than diesel. Care should be taken to provide at least the minimum amount of ventilation recommended when burning diesel.

STORAGE OF FUEL
Always store kerosene and diesel in a well ventilated area well away from general living space. Do not store in direct sunlight or near a source of heat or other source of ignition such as a torch or a portable generator.Do not use fuel that has been stored from one season to the next as it may have deteriorated and will not burn properly in the heater. Store the fuel in a suitable container which complies with requirements set out in local authority regulations.

OPERATION (REFER TO FIG.1A)SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-3

STARTUP
Fill the tank with clean fuel. Only use Diesel or Kerosene. The fuel gauge on top of the tank allows checking the fuel level. Connect the power cord plug to an AC220-240V 50 Hz earthed electrical supply system. Earthing is mandatory. fig.1A Push the power switch to “ON”(1) position. If the ambient temperature is lower than the default temperature, the electrodes start sparking, after 7 seconds, the heater starts. If the ambient temperature is higher than default temperature, turn the thermostat control knob to desired temperature, the electrodes start sparking, after 7 seconds, the heater starts.

COLD START-UP
At low temperature keep the air vent hole fig.4 closed by a finger during ignition to make start-up easier. ABNORMAL OPERATION: in case of malfunction (flame failure, reduced air flow, bad combustion, etc.) the heater stops and the indicator light starts FLASHING.

MANUAL RESET/RESTART
If the heater is in lock-out mode, check and remove the cause of lock-out before restarting the heater. To reset, turn the ON/OFF switch to 0 and then again to I. In case of repeated malfunction, call technical service. Turning the thermostat control knob will NOT reset the heater.

SHUT DOWN
Move the switch to the “OFF” (O) position. The heater will run a post-ventilation phase to cool down the combustion chamber. Unplug the unit when not used for a long time.
Never disconnect the heater from mains to stop it while in operation. Always allow the cooling sequence to be completed, otherwise the residual heat could damage internal components.

  • DO NOT cover the heater.
  • DO NOT block the air inlet and outlet.

WARNING! The heater outlet is very hot during operation and after use. DO NOT TOUCH! Use personal protecting equipment if needed.Children should be supervised to ensure that they do not play with the appliance.

Note: The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
Unplug the heater before moving it. Never pull the cable to unplug or move the unit.

  • DO NOT leave the heater unattended when in use.
  • Never use the appliance with wet hands or when either the heater or the power cable is wet.

WARNING! If the supply cable is damaged, it must be replaced by the manufacturer, by a service agent or a similar qualified person.

CLEANING & MAINTENANCE

WARNING! Before starting any maintenance task, shut down, unplug and let the heater cool down for at least 15 minutes.DO NOT attempt any electrical repair yourself. If the heater needs service or repair, contact a qualified technician.DO NOT use a faulty unit unless a qualified technician has inspected and repaired it.9
When cleaning, make sure that water does not enter the unit.DO NOT open the enclosure to clean the inner parts. DO NOT spray water into the heater.8
Never use solvents, gasoline, toluene and similar aggressive chemicals to clean the heater Regularly wipe the enclosure using a soft sponge or cloth. For very dirty parts, use a sponge wetted with lukewarm water and a milddetergent, then dry using a clean cloth. Keep air inlet and fan free from dust and dirt. To clean inner parts, gently blow compressed air through air inlet. Regularly inspect the power cable: if worn, cracked or damaged have it replaced by technical service. Before storing the heater , make sure it is perfectly cool and dry. Cover the unit with a plastic bag, put it in its packing box and store it ina dry, ventilated place.

LONG TERM STORAGE
If the heater is to be stored for a long period of time, drain the fuel through the fuel cap opening. Rinse and swirl a small amount of fuelwithin the tank and then empty it fully. When you come to use the heater again do not use old fuel which has been stored from theprevious season. Use of old fuel can damage your heater. Although our heaters operate with diesel fuel, when the temperature is below 0°C diesel additives are required to maintain the diesel’sviscosity. Typically diesel can cloud in freezing conditions and will start to gel. You will need additives for your fuel in these conditions. Kerosene does not start to gel until the ambient temperature is around -40°C.

Refer to fig.1B.
DO NOT use paraffin in these heatersSEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-4

MAINTENANCE

The following checks BY QUALIFIED PERSONNEL ONLY are recommended before every seasonal use: Nozzle
Carefully unscrew nozzle from nozzle fitting. Blow compressed air through nozzle orifice to free it from dirt. Replace nozzle if necessary. Air Filters
Clean air filters. Remove filter end cover (11), wash air intake filter (10) using a light detergent and dry it thoroughly before re-installing.
Replace air delivery filter (9) once a year fig.2.SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-5

 

ignition Electrodes fig.3
Clean and if necessary replace the ignition electrode. For electrode gaps see fig.3.

SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-6

WARNING! The compressor pressure is factory set and must be checked by qualified technicians only. Tampering with the unit may be dangerous. Remove pressure gauge cap. Connect a pressure gauge on the pressure measuring port on the rear guard. Start heater and read air pressure value. If necessary adjust pressure to correct value by turning the adjusting screw (the air vent hole in the adjusting screw middle) clockwise to increase, anticlockwise to decrease the pressure.

  • Model AB2050
  • Air Pressure (bar) 0.43SEALEY-AB2050-Space-Warmer-Kerosene-Diesel-Heater-FIG-7

TROUBLESHOOTING

PROBLEM CAUSE REMEDY
Motor does not start

 

 

 

 

Power indicator light is flashing

No power or low voltage Check power line and voltage
Faulty or damaged mains cable Check fuse and replace if needed
Faulty motor/capacitor Check and if necessary replace
Lockout of appliance due to previous overheating Detect the cause of the overheating Shut the appliance down

Check air inlet and outlet

Wait a few minutes and restart the heater

Motor runs, but the heater does not ignite and locks out after a short time

 

 

 

Power indicator light is flashing

Empty fuel tank, dirty or wrong fuel Remove wrong or dirty fuel

Fill tank with clean diesel or kerosene

Fuel filter clogged Clean or replace fuel filter
Air leaks on oil line Check hoses, tighten connections, if necessary replace
Burner nozzle clogged Clean nozzle with compressed air, replace if necessary
Fuel viscosity increased at low temperature Mix diesel with 10-20% kerosene
Flames come out of flue outlet Insufficient airflow into combustion chamber Check air inlet, fan, motor
Compressor pressure too high Check air pressure , adjust if needed
Heater stops during operation The room temperature set on room thermostat has been reached Normal operation

To start turn temperature control knob clockwise onto a higher setting

Heater stops during operation Power indicator light is flashing Flame failure Check and remove the cause of the malfunction

To reset, turn On/Off switch to 0 and then

to I

Call technical service if problem persists

Bad combustion
Reduced airflow
Overheating

WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk

Documents / Resources

SEALEY AB2050 Space Warmer Kerosene Diesel Heater [pdf] Instructions
AB2050, Space Warmer Kerosene Diesel Heater, AB2050 Space Warmer Kerosene Diesel Heater, Warmer Kerosene Diesel Heater, Kerosene Diesel Heater, Diesel Heater, Heater

References

Leave a comment

Your email address will not be published. Required fields are marked *