SOLAX POWER - Logo

Quick Installation Guide
X1/X3-EVC Series 7.2 kW-22 kW
(Commercial Edition)

Packing List

SOLAX POWER X3 EVC Series Commercial Edition - Packing List

Installation Steps

STEP 1: Remove the screw from the EV-Charger with the cross screwdriver. Then remove the back bracket away carefully.

SOLAX POWER X3 EVC Series Commercial Edition - Installation StepsSTEP 2: Fix the back bracket and the cable hook (only for Plug Type) to the wall.

– Mark the position of the holes.
– Drill holes with φ 8 drill.
– Depth: at least 45 mm.
– Insert the expansion bolts. – Align the bracket and the cable hook (only for Plug Type)
with the holes, and screw the self tapping screws with the
cross screwdriver.
SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 2 SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 3 SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 4

STEP 3: Hang the EV-Charger on the wall for trial, then estimate the required length of input cable (three-core for single-phase, five-core for three-phase, outer diameter: 12.5-18  mm) and communication cable. After that, take the EV-Charger down.
STEP 4: Unscrew the EV-Charger’s rear cover with the cross screwdriver and take it down. Then undo the fastening heads and take the waterproof materials away as shown below.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 5

STEP 5: Unscrew the countersunk screw of the base plate of communication board with the cross screwdriver. Then pull the base plate of communication board out.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 6

STEP 6: Insert the (extended) communication cable of the meter or CT or other devices through the waterproof connector in sequence as shown below. (For the installation of CT or  meter, please refer to the “CT/Meter Connection” section.)
STEP 7: Strip the outer sheath of the input cable as below, ensuring all the wires can reach the terminal blocks with a little excessive length. Use the stripping pliers to strip approx. 12  mm of insulation from the end of all the coloured wires as below. Then crimp the European terminal with the wire crimper.
STEP 8: Insert the input cable through the waterproof connector in sequence as shown below.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 7

STEP 9: Insert the wires into the appropriate holes of the terminal blocks, then block the terminals with the straight screwdriver.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 8

STEP 10: Press the spring upward and push the base plate of communication board in. Then screw the countersunk screw.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 9

STEP 11: Push the rear cover to appropriate position of the cables and screw the self tapping screws with the cross screwdriver. Then tighten the waterproof fastening heads.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 10

STEP 12: Hang the EV-Charger up carefully and steady the EV-Charger with the self tapping screw and the cross screwdriver.

SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 11 For Plug Type, connect the charging connector with the EV-Charger and hang the connecting cable on the hook.
SOLAX POWER X3 EVC Series Commercial Edition - Installation Steps 12

CT/Meter & WiFi Connection

► CT/Meter Connection
Diagram:

• For “Private Charger” Scenarios • For “Commercial Charger(OCPP)” Scenarios
SOLAX POWER X3 EVC Series Commercial Edition - WiFi Connection 1 SOLAX POWER X3 EVC Series Commercial Edition - WiFi Connection 2

Note:

  1. If a CT is installed with EV-Charger, the arrow on the CT must point at the public grid.
  2. For the installation of the meter, please refer to the relative quick installation guide for details.

SOLAX POWER X3 EVC Series Commercial Edition - WiFi Connection 3

► WiFi Connection
Step 1: Use your smart phone to scan below QR code or search for the keyword “SolaXCloud” in browser to download the Monitoring App.

SOLAX POWER X3 EVC Series Commercial Edition - Qr Code 1 SOLAX POWER X3 EVC Series Commercial Edition - Qr Code 2
https://itunes.apple.com/cn/app/solaxcloud/id1300059673?mt=8 https://play.google.com/store/apps/details?id=com.solaxcloud.starter

Step 2: Create a new account on the Monitoring App.
Step 3: Login and turn to Account page in the app. Then click “Wifi Connection” and follow the instructions to complete the process.

SOLAX POWER X3 EVC Series Commercial Edition - WiFi Connection 4

*If manual WiFi conguration is required, the IP address is http://192.168.10.10/.