CleanAIR-LOGO

CleanAIR CNA-095-R07 Safety Helmet

CleanAIR-CNA-095-R07-Safety-Helmet-PRODUCT

Specifications:

  • Model: CNA-095-R07 UniMask
  • Respiratory and face protection
  • Adjustable airflow direction
  • Exhalation valve membrane replacement
  • Visor replacement
  • Face seal removal and attachment
  • Cleaning and maintenance instructions

Product Usage Instructions

Introduction

The UniMask provides overpressure in the headtop to prevent contaminants from entering the breathing zone. It offers comfort during long-term use and easy breathing without filter resistance.
This mask provides respiratory and face protection against high-speed, high-energy particles.

Limitations on Use

  1. Replace damaged protection foil immediately.
  2. The hood does not protect against hard shocks, explosions, or corrosive substances.
  3. Take appropriate measures in case of damage.

Control and Spare Parts Replacement

  • Adjusting Airflow Direction: Use the slider control knobs to adjust airflow from top, bottom, or mouth.
  • Changing Exhalation Valve Membrane: Remove old membrane, place new one, and cover with plastic.
  • Replacing Visor: Remove and replace visor ensuring proper fit.
  • Removing and Attaching Face Seal: Remove old seal, attach new seal by fitting grooves into shield grooves.

Cleaning and Maintenance
Check the hood daily for damage. Do not use acetone or cleaning solvents. Proper maintenance enhances longevity and safety.

Frequently Asked Questions (FAQ):

Q: How often should I check the hood for damage?
A: It is recommended to check the hood daily for any signs of damage on both the inside and outside surfaces.

Q: Can I use acetone for cleaning the hood?
A: No, acetone or other cleaning solvents should not be used for cleaning the hood. It is advised to follow the recommended cleaning instructions provided in the manual.

Important
For your own safety please read and remember the following instructi-ons before use. If you have any questions, please contact the manufacturer or your distributor. Keep the manual for future reference.

Introduction

CleanAIR® UniMask is adapted for use with powered air-purifying respirators (hereinafter PAPR) CleanAIR® or with continuous flow compressed air line breathing apparatuses (hereinafter “compressed air systems CleanAIR®) and thus provides protection of the respiratory tract.
The overpressure created in the headtop prevents contaminants from entering the breathing zone. This ensures the wearer’s comfort, even with long-term use. Breathing remains easy because the user does not have to overcome the resistance of the filter.

UniMask provides respiratory protection and face protection against particles with high speed and high energy impact.
If not sure about the suitability of the hood for a specific application, consult with the manufacturer or your supplier!

Limitations on use

  1. Never use the hood in the following environments and under the following conditions:
    • If oxygen concentration in the environment is lower than 17 %.
    • In oxygen-enriched environments.
    • In environments where the user lacks knowledge about the type of dangerous substances and their concentration.
    • In environments that represent an immediate danger to life and health.
  2. If the protection foil is damaged, replace it immediately.
  3. The hood does not protect against hard shocks, explosions or corrosive substances.
  4. Move to a secure location and take appropriate measures when any of the following problems occur while using the hood:
    • If you feel a significant increase in breathing resistance or any other problems with breathing.
    • If you experience stench, irritation or an unpleasant taste while breathing.
    • If you feel unwell or experience nausea.
  5. Use certified original filters designed for your powered air purifying respirator only. Replace filters every time you detect the change of odour in supplied air from the respirator.
  6. Filters designed for capturing solid and liquid particles (particle filters) do not protect the user against any gases. Filters designed for capturing gases do not protect the user against any particles. In the workplace contaminated with both particles and gases, combined filters must be used.
  7. The material of the hood can cause allergic reactions to sensitive persons.
  8. Pay attention to check the product before use. Do not use, if any part of the system is damaged.
  9. Don’t put the hood on a hot surface.
  10. This product is intended for use in environments with a tem-perature range of 0 °C to + 60 °C with relative humidity of 20 – 95 % Rh.

Control and spare parts replacement

Adjusting the airflow direction
By sliding the slider control knobs on the bottom front of the mask you can adjust the airflow in three ways (airflow on the visor from the top, on the visor from the bottom and airflow toward the mouth). By closing both knobs all the airflow will enter from the top. By opening both knobs the airflow will be evenly divided between all openings when entering the mask.

Changing the exhalation valve membrane
Remove the plastic cover followed by the old membrane. Put the new membrane on the plastic pin in the original place. Put the plastic cover back.

Replacing the visor
Shift the visor locks on both sides up (open) and remove the visor. Place the new visor on the same spot and shift both locks on the sides back down (lock). Make sure the visor fits properly.

Removing the face seal
First remove the visor, then remove the face seal by pushing it out of the mask using your thumbs. The easiest way is to start on the side, just above the visor locks.

Attaching the new face seal
Start by placing the face seal grooves into the grooves of the shield on the left side, make sure the triangular indicators on both parts match. Hold the parts in the right position with one hand while pushing the parts in the right position with the other hand, starting on the top, followed by the bottom and finally the opposite side. Make sure the seal fits correctly on to the shield.

Cleaning and maintenance

The lifetime of the hood and visors is influenced by many factors such as cold, heat, chemicals, sunlight or incorrect use. The hood should be checked on a daily basis on possible damage of its structure on the inside and the outside. Careful use and correct mainte-nance of the protective hood enhances operating life and improves your safety!

Checking before use:
Inspect that every part of the hood is undamaged and installed correctly.

Cleaning:

  • After each work shift, clean the hood, check individual parts, and replace damaged ones.
  • Cleaning must be performed in a room with sufficient ventilation. Avoid inhalation of harmful contaminants settled on individual parts!
  • For cleaning of plastic parts use lukewarm water (up to +40 °C) with soap or another non-abrasive detergent, and a soft brush.
  • The face seal can be washed in a washing machine or dishwasher at a maximum temperature of 30 ° C. The face seal can be dried in a dryer at a speed not exceeding 800 rpm. Wash the face seal separately – it must be removed from the mask before maintenance.
  • After cleaning individual parts with a damp cloth, it is necessary to rub them dry or let them dry at room temperature.
  • Care for the visors and plastic parts, it is recommended to use the CleanAIR® ®klar-pilot Fluids.

Do not use acetone or other cleaning solvents!

Materials

Part Material
Hood Polyamide
Faceseal Neoprene or 3D polyamide knit
Visor TR1 Polycarbonate (PC) or amorphous polyamide (aPA)
 

Visor CR1

Cellulose propionate (CP) or polycarbonate(PC)/ PC+ABS

Storage conditions
Store the hood in a dry and clean place at room temperature, avoid direct sunlight (temperature range from -10 °C to +55 °C) with rela-tive humidity between 20 and 95 % Rh).

Warranty
The warranty ensures that you will receive a replacement if a product has any manufacturing or material defects that appear within 12 months of the date of purchase. The warranty claim must be reported to the sales department/retailer. At the same time, proof of purchase must be submitted (i.e. an invoice or certificate of delivery). The warranty can only be acknowledged if no interventions into the hood have been made.

List of products and spare parts

Table 1: Product name and product code

Product code Product description
72 03 00.01 Protective face shield UniMask, grey
72 03 00.02 Protective face shield UniMask, blue
72 03 00.03 Protective face shield UniMask, orange
72 03 00.04 Protective face shield UniMask, red
72 03 00.08 Protective face shield UniMask, neoprene

Table 2: List of spare parts

Product code Product description
72 03 20/10 Protection film UniMask, pack of 10 pcs
72 03 40 Head band UniMask
72 03 45 Head harness UniMask 5-point
72 90 00 Spare visor TR1, clear
72 90 01 Spare visor TR1, yellow
72 90 03 Spare visor TR1, shade 3
72 90 05 Spare visor TR1, shade 5
72 90 90 Spare protective visor TR1, clear, aPA, chemically resistant
72 91 00 Spare visor CR1, clear, CP
72 03 50.01 Face seal UniMask, grey
72 03 50.02 Face seal UniMask, blue
72 03 50.03 Face seal UniMask, orange
72 03 50.04 Face seal UniMask, red
72 03 50.08 Face seal UniMask, neoprene
72 03 60 Protective hood UniMask, short
72 03 61 Protective hood UniMask, long
72 03 62 Protective hood UniMask, washable fabric

Approved combinations

Product code Product description Level of protection
30 00 00PA AerGO® TH3
51 M0 00FC MedicAER TH3
81 00 00PA Basic TH3
51 00 00FCA Chemical 2F TH3
52 00 00CFA Chemical 3F TH3
63 00 00 Pressure 2A
67 00 00 Pressure Flow Master 3B

The level of protection is also ensured even if classic-rimmed glasses are used.

These products are approved in compliance with the following standards:

Notified body for the CE approval:

EN 12941:1998+A2:2008 & EN 14594:2005
Occupational Safety Research Institute, v.v.i. Jeruzalémská 1283/9, 110 00 Prague 1, Czech Republic Notified body 1024

EN 166
Institute for testing and certification, a.s.
Třída Tomáše Bati 299, 764 21 Zlín, Czech Republic Notified body 1023

Declaration of Conformity is available at: https://www.clean-air.cz/doc

Markings and symbols according to EN 166:

UniMask® frame marking:
EN 166 MS 3 4 5 9 FT B 5/2-5
UniMask® compatible visors marking
Visor Description Visor marking Field of use
72 90 00 TR1, clear PC 2C-1,2 MS 1 FT B 9 K N 3 4 5 9
72 90 01 TR1, yellow PC 2C-1,2 MS 1 FT B 9 K N 3 4 5 9
72 90 03 TR1, shade 3 PC 3/2-3 MS 1 FT B 9 K N 3 4 5 9
72 90 05 TR1, shade 5 PC 5/2-5 MS 1 FT B 9 K N 3 4 5 9
72 90 90* TR1, clear aPA MS 1 FT 3 4
72 91 00 CR1, clear CP MS 1 S N 3 4 5
72 91 01* CR1, clear PC MS 1 FT 3 4 5

not suitable for use in ATEX zone

Marking description
MS Manufacturer identification (MALINA – Safety s.r.o.)
166 Standard EN 166
3; 5 Shade number – welding filter (EN 169)
2C Code number – UV protection with good colour recog- nition (EN 170)
2 Code number – UV protection (EN 170)
1,2;

3; 5

Shade number – UV protection (EN 170)
1 Optical class
A (T) Mechanical strenght – High energy impact (190 m/s)
B (T) Mechanical strenght – Medium energy impact (120 m/s)
F (T) Mechanical strenght – Low energy impact (45 m/s)
S Mechanical strenght – Increased robustness

If the letter (A, B, F) is followed by the letter „T“, then the frame protects against impact at extreme temperatures (-5°C / +55°C)

3 Field of use – Liquids (droplets or splashes)
4 Field of use – Large dust particles
5 Field of use – Gas and fine dust particles
9 Field of use – Splashes of molten metal and penetration of hot solids
K Resistance to surface damage by fine particles
N Resistance to fogging

Illustrational

How to adjust airflow direction

CleanAIR-CNA-095-R07-Safety-Helmet-1

Changing exhalation valve membrane

CleanAIR-CNA-095-R07-Safety-Helmet-2

How to change the visor

CleanAIR-CNA-095-R07-Safety-Helmet-3

Removing the face seal

remove the visor first

CleanAIR-CNA-095-R07-Safety-Helmet-4

How to attach the new face seal

CleanAIR-CNA-095-R07-Safety-Helmet-5

CleanAIR-CNA-095-R07-Safety-Helmet-6

How to attach the UniMask 5-point head harness

CleanAIR-CNA-095-R07-Safety-Helmet-7

MALINA – Safety s.r.o. Luční 11,
466 01 Jablonec n. Nisou Czech Republic

Tel. +420 483 356 600
export@malina-safety.cz
www.malina-safety.com

Documents / Resources

CleanAIR CNA-095-R07 Safety Helmet [pdf] User Manual
CNA-095-R07 Safety Helmet, CNA-095-R07, Safety Helmet, Helmet

References

Leave a comment

Your email address will not be published. Required fields are marked *