MITSUBISHI ELECTRIC TPKA0A0121LA10A Split System Heat Pump Wall Mounted Indoor unit
Specifications
- Product: Mitsubishi Electric Trane HVAC US Split-System Heat Pump
- Model Name: TPKA0A0121LA10A, TPKA0A0181LA10A
- Parts Catalog No.: TCBT012
- Published: February 2023
Product Usage Instructions
Installation
- Refer to the service manual (TCHT012) for detailed installation instructions.
- Ensure all parts listed in the service parts list are present before starting the installation.
- Follow the wiring diagram symbols for proper connection of parts.
Maintenance
- Regularly clean the air filter (Part No. 7) for efficient operation.
- Inspect and clean the indoor coil thermistor (Part No. 6) periodically.
- Check the electrical cover (Part No. 14) and box (Part No. 15) for any signs of damage.
Operation
- Use the wireless remote or wired remote controller for operating the heat pump.
- Ensure proper placement of the remote sensor for accurate temperature readings.
- Familiarize yourself with the menu options for setting preferences.
FAQ
- Q: Where can I find replacement parts for the heat pump?
- A: You can refer to the service parts list in the manual for part numbers and contact Mitsubishi Electric Trane HVAC US for replacements.
- Q: How often should I clean the air filter?
- A: It is recommended to clean the air filter every 1-2 months depending on usage and air quality.
- Q: Can I install the heat pump without professional assistance?
- A: It is recommended to have a professional HVAC technician install the heat pump to ensure proper installation and performance.
PARTS
SERVICE PARTS LIST
PANEL AND HEAT EXCHANGER PARTS
- TPKA0A0121LA10A
- TPKA0A0181LA10A
- The part quantity below indicates the required number of pieces per unit.
- The circled No. indicates that the part is not shown in the figure
No. |
Parts No. |
Parts Name |
TPKA0A0121LA10A | TPKA0A0181LA10A |
Wiring Diagram Symbol |
Remarks |
1 | E27 P68 970 | INSTALLATION PLATE | 1 | 1 | ||
2 | E27 P68 234 | BOX ASSEMBLY | 1 | 1 | ||
3 | E 27 Y98 976 | CORNER BOX L | 1 | 1 | ||
4 | E 27 Y98 975 | CORNER BOX R | 1 | 1 | ||
5 | E27 21F 620 | INDOOR HEAT EXCHANGER | 1 | 1 | ||
6 | E27 13D 307 | INDOOR COIL THERMISTOR | 1 | 1 | TH2, TH5 | |
7 | E27 58G 100 | AIR FILTER | 2 | 2 | ||
8 | E27 P63 021 | ARM HOLDER SET | 1 | 1 | set (left, right) | |
9 | E27 10A 010 | FRONT PANEL | 1 | 1 | ||
10 | E22 F95 142 | CATCH | 2 | 2 | 2 pcs/set | |
11 | E22 98B 067 | SCREW CAP | 2 | 2 | 2 pcs/set | |
12 | E27 10A 000 | PANEL ASSEMBLY | 1 | 1 | Includes 8, 9, 10, 11 |
FAN AND ELECTRICAL PARTS
- TPKA0A0121LA10A
- TPKA0A0181LA10A
- The part quantity below indicates the required number of pieces per unit.
- The circled No. indicates that the part is not shown in the figure.
No. |
Parts No. |
Parts Name |
TPKA0A0121LA10A | TPKA0A0181LA10A |
Wiring Diagram Symbol |
Remarks [Drawing No.] |
||
1 | E2 2 | T20 | 7 0 2 | DRAIN HOSE | 1 | 1 | ||
2 | E27 | 42R | 705 | DRAIN CAP | 1 | 1 | ||
3 | E27 | 77G | 235 | NOZZLE ASSEMBLY | 1 | 1 | Full assembly except drain hose | |
4 | E27 | 103 | 303 | VANE MOTOR (UPPER) | 1 | 1 | MV1 | |
5 | E22 | Y54 | 303 | VANE MOTOR (LOWER) | 1 | 1 | MV2 | |
6 | E27 | 77G | 040 | VANE UPPER | 1 | 1 | ||
7 | E27 | 77G | 041 | VANE LOWER | 1 | 1 | ||
8 | E2 7 | 2 1F | 3 7 5 | TERMINAL BLOCK | 1 | 1 | TB4 | |
9 | E27 | 249 | 375 | TERMINAL BLOCK | 1 | 1 | TB5 | |
10 | E27 | P63 | 308 | ROOM TEMP. THERMISTOR | 1 | 1 | TH1 | |
11 | E27 | Y99 | 468 | DISPLAY AND RECEIVER P.C. BOARD | 1 | 1 | L.B., W.B., S.B. | |
12 | E27 | P63 | 095 | DISPLAY RECEIVER HOLDER | 1 | 1 | ||
13 | E27 | 58R | 447 | INDOOR CONTROLLER BOARD | 1 | 1 | I.B. | |
14 | E27 | P63 | 333 | MOTOR BAND | 1 | 1 | ||
15 | E27 | P63 | 541 | WATER COVER | 1 | 1 | ||
16 | E27 | P64 | 333 | MOTOR BED | 1 | 1 | ||
17 | E27 | 13D | 300 | INDOOR FAN MOTOR | 1 | 1 | MF | Includes rubber mounts |
18 | E27 | P68 | 302 | LINE FLOW FAN | 1 | 1 | ||
19 | E22 | A89 | 509 | BEARING MOUNT ASSEMBLY | 1 | 1 | ||
20 | E27 | Y98 | 978 | CONDUIT PLATE SET | 1 | 1 | ||
21 | E22 | C32 | 667 | UNION 1/4″ | 1 | 1 | for liquid | |
22 | E22 | 179 | 667 | UNION 1/2″ | 1 | 1 | for gas |
OPTIONAL PARTS
Parts name | Parts No. |
Wired Remote Controller | TAR-41MAA, TAC-YT53CRAU |
Wireless remote controller | PAR-SL101A-E |
External Drain pump kit | PAC-SK01DM-E |
Remote Sensor | PAC-SE41TS-E |
Connector cable for Remote Display | PAC-SA88HA-EP |
Heater control relay adapter | PAC-SE56RA-E |
MITSUBISHI ELECTRIC TRANE HVAC US LLC
HEAD OFFICE: 1340 SATELLITE BOULEVARD, SUWANEE, GA 30024, USA
MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD. 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000 THAILAND Published: Feb. 2023 No. TCBT012 Made in Thailand