MEAN WELL NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power Inverter
Product Information
Specifications
- Model: NTS-450 series
- Input Power: 450W
- Waveform: True Sine Wave
- Compliance: IEC62368-1, BS EN/EN62368-1, AS/NZS 62368.1
- Output: AC
Product Usage Instructions
Installation
- Ensure the DC input side is securely connected to a compatible power source.
- Place the inverter in a well-ventilated area with sufficient airflow.
- Connect the AC output side to the device you wish to power.
Operation
- Turn on the DC input side to supply power to the inverter.
- The inverter will convert the DC power to AC power with a true sine wave output.
- Use the AC output to power your mobile devices or other compatible equipment.
Maintenance
Regularly check for any loose connections or signs of wear and tear. Clean the inverter as needed to prevent dust buildup.
FAQ
- Q: What should I do if the inverter is not powering my devices?
A: Check the connections and ensure the input power source is functioning correctly. If issues persist, consult the user manual for troubleshooting tips or contact customer support. - Q: Can this inverter be used in a vehicle?
A: Yes, this inverter’s compact size and light weight make it suitable for use in vehicles to power mobile devices and other electronics.
Features
- Compact size and lightweight
- True sine wave output (THD<3%)
- High surge power up to 900W
- Temperature-controlled cooling fan
- AC output voltage and frequency selectable by DIP S. W
- No load disspation <1.5W max. at standby saving mode
- -25°C~+70°C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections:
- Input: Reverse polarity / DC low alarm / DC low shutdown / Over voltage
- Output: Short circuit / Overload / Over temp.
- Battery over-discharge protection(Low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Mobile device
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
NTS-450 is a 450W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high-quality fan with low acoustic noise, 900W peak power, adjustable AC output voltage and frequency, -25~+70 C wide operating temperature range, complete protections features, etc. combined with batteries, the NTS-450 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, etc.
Model Encoding
SPECIFICATION
MODEL NO. | NTS-450-112 | NTS-450-124 | NTS-450-148 | NTS-450-212 | NTS-450-224 | NTS-450-248 | ||||||
= US, GFCI, UN | = EU, CN, AU, UK, UN | |||||||||||
AC OUTPUT | RATED POWER(Continuous) | 450W | ||||||||||
OVER RATED POWER(3 Min.) | 517.5W | |||||||||||
PEAK POWER(10 Sec.) | 675W | |||||||||||
SURGE POWER(30 Cycles) | 900W | |||||||||||
AC VOLTAGE | Default setting set at 110VAC | Default setting set at 230VAC | ||||||||||
100 / 110 / 115 / 120Vac selectable by DIP S.W | 200 / 220 / 230 / 240Vac selectable by DIP S.W | |||||||||||
FREQUENCY | Default setting set at 60Hz±0.1Hz | Default setting set at 50Hz±0.1Hz | ||||||||||
50/60Hz selectable by DIP S.W | 50/60Hz selectable by DIP S.W | |||||||||||
WAVEFORM Note.1 | True sine wave (THD<3%) | |||||||||||
AC REGULATION | ±3.0% at rated output voltage | |||||||||||
FRONT PANEL LED | Please refer to page5 | |||||||||||
DC INPUT | DC VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V | |||||
VOLTAGE RANGE (Typ.) | 10 ~ 16.5Vdc | 20 ~ 33Vdc | 40 ~ 66Vdc | 10 ~ 16.5Vdc | 20 ~ 33Vdc | 40 ~ 66Vdc | ||||||
DC CURRENT (Typ.) | 50A | 25A | 14A | 50A | 25A | 14A | ||||||
NO LOAD DISSIPATION
(Typ.) |
NON-SAVING MODE | 10W | 10W | 12W | 10W | 10W | 12W | |||||
SAVING MODE |
Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode | |||||||||||
1.2W | 1.3W | 1.5W | 1.2W | 1.3W | 1.5W | |||||||
OFF MODE CURRENT DRAW | ≦1mA | |||||||||||
EFFICIENCY (Typ.) Note.1 | 88% | 91% | 91% | 90% | 93% | 93% | ||||||
BATTERY TYPES | Lead Acid or li-ion | |||||||||||
PROTECTION | DC INPUT | FUSE (Internal) | 40A*2 | 40A*1 | 10A*2 | 40A*2 | 40A*1 | 10A*2 | ||||
LOW | ALARM | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | |||||
SHUTDOWN | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | ||||||
RESTART | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | ||||||
HIGH | ALARM | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | |||||
SHUTDOWN | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | ||||||
RESTART | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | ||||||
BAT. POLARITY | By internal fuse open | |||||||||||
AC OUTPUT | OVER TEMPERATURE | Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |||||||||||
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |||||||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||||
GFCI PROCTECTION |
Design refer to UL458
(Only for “GFCI” AC socket , by request) |
None |
||||||||||
FUNCTION | REMOTE CONTROL | Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open : Normal work ; Short , Remote off | ||||||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃(Refer to “Derating curve”) | ||||||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||||||
STORAGE TEMP., HUMIDITY | -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing | |||||||||||
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||||
SAFETY & EMC (Note.4) | SAFETY STANDARDS | CB IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004 approved;Design refer to AS/NZS 62368.1 (Please refer to next page“AC output socket” table for more details) ; Design refer to UL458 (By request) | ||||||||||
WITHSTAND VOLTAGE | DC I/P – AC O/P:3.0KVac AC O/P – FG:1.5KVac | |||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||||||||
Radiated | FCC for 112,124,148 only(expect for Type-UN) | Class A | ||||||||||
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) | Class A | |||||||||||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||||||
EMC IMMUNITY | BS EN/EN55024, BS EN/EN55035 | |||||||||||
Parameter | Standard | Test Level / Note | ||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||||||
Radiated | BS EN/EN61000-4-3 | Level 2 , 3V/m | ||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 1 , 1A/m | ||||||||||
OTHERS |
MTBF | 843.9K hrs min. Telcordia TR/SR-332 (Bellcore) ; 85K hrs min. MIL-HDBK-217F (25℃) | ||||||||||
DIMENSION | 210*130*55mm (L*W*H) | |||||||||||
PACKING | 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT | |||||||||||
NOTE | 1. Efficiency, AC regulation and THD are tested by 450W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
2. All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting. 3. Internal pre-start circuit, the setup time is 8s. 4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
AC Output Socket
DERATING CURVE
Remote ON-OFF Control
Remote ON-OFF | AC Output Status |
Open | power inverter ON |
Short | power inverter OFF |
AC Output Voltage, Frequency, Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW | ||||
SW1 | SW2 | SW3 | SW4 | |
OFF | OFF : | 100Vac or 200Vac | ON: 50Hz | ON: Saving mode |
OFF | ON : | 110Vac or 220Vac | ||
ON | OFF : | 115Vac or 230Vac | OFF: 60Hz | OFF: Non-Saving mode |
ON | ON : | 120Vac or 240Vac |
LED STATUS
Normal work:
Abnormal status:
MECHANICAL SPECIFICATION
Accessory List
※Carry handle (Optional accessory, Power inverter and Pull handle should ordered separately).
TYPICAL APPLICATION
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
Documents / Resources
MEAN WELL NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power Inverter [pdf] Owner's Manual NTS-450-124UN, NTS-450-20231211, NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power Inverter, NTS-450 Series, 450W High Reliable True Sine Wave DC to AC Power Inverter, 450W DC to AC Power Inverter, High Reliable True Sine Wave DC to AC Power Inverter, DC to AC Power Inverter, Power Inverter, Inverter |