STUART-TURNER-LOGO

STUART TURNER 47505 Pulse Trade 25-60 130 Circulating Pump

STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-PRODUCT

Specifications

  • Product Name: STUART Pulse Trade 25-60/130
  • Part Number: 47505
  • Intended Users: Children aged 8 years and above, persons with reduced physical, sensory, or mental capabilities

Product Information

  • The STUART Pulse Trade 25-60/130 is designed to provide efficient and reliable operation for various applications.
  • It is suitable for use by individuals with proper supervision and an understanding of the safety hazards involved.

Installation Instructions

  1. Read the installation details carefully before commencing installation to ensure long-term trouble-free service.
  2. Follow the installation instructions provided to prevent invalidation of the warranty.
  3. Ensure the unit is installed by the specified guidelines.

Operation Guidelines

When operating the STUART Pulse Trade 25-60/130, observe the following safety instructions:

  • Do not allow children to play with the appliance.
  • Do not conduct cleaning or maintenance operations without proper supervision.
  • Observe all warning symbols and signs attached to the product.

Maintenance

Regular maintenance is essential to ensure optimal performance of the product.

Follow these maintenance guidelines:

  • Refer to the maintenance instructions provided in the manual.
  • Perform routine checks on the unit to identify any issues early.
  • Keep the product clean and free from debris.

FAQ

Q: Can children operate the STUART Pulse Trade 25-60/130?

  • A: This appliance can be used by children aged 8 years and above with proper supervision and instruction on safe usage.

Q: What should I do in case of a fluid leak?

  • A: In case of a fluid leak, ensure that any fluids are collected or diverted to prevent hazards to persons and the environment.
  • Please leave this instruction booklet with the end user as it contains important warranty, maintenance, and safety information
  • Read this manual carefully before commencing installation.

This manual covers the following products:

WARNINGS:

  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in
  • a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be done by children without supervision.
  • The motor casing can become very hot under normal operating conditions. Care must be taken to ensure it cannot be touched during operation.
  • The electrical installation must be carried out under the current national electrical regulations.
  • The electrical installation must be installed by a qualified person.
  • Do not run the pump dry.
  • System pressure must not exceed 10 bar.
  • Before starting work on the electrical supply ensure the power supply is isolated.
  • DO NOT allow the supply cord to contact hot surfaces, including the motor shell, pump body, or pipework. The cord should be safely routed and secured by cable clips.
  • This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in the terminal box.
  • Please read installation details carefully as they are intended to ensure this product provides long, trouble-free service.
  • Failure to install the unit under the installation instructions will lead to invalidation of the warranty.

Safety Instructions

General

  • These installation and operating instructions are a part of the product and contain basic information that must be observed during installation, operation, and maintenance.
  • For this reason, the installer and specialist personnel or operators must read these instructions before set-up.
  • Please observe both the general safety instructions listed under section 2 and the special safety instructions detailed in the other sections.
  • A copy of the EC Declaration of Conformity is provided with these instructions. This declaration shall be deemed void in the event of a modification that has not been agreed with us.

Identification of symbols in the operating instructions

  • General hazard symbol Warning! The danger of personal injury! Observe the relevant accident prevention regulations.
  • Warning! Danger from electrical voltage! Prevent hazards arising from electrical energy.
  • Observe the instructions in local or general regulations (e.g. IEC, VDE, etc.), and those of the local energy supplier.
  • Bold text indicates useful information for handling the product. It indicates potential difficulties and aims to ensure safe operation.

Signs attached directly to the product, such as:

  • the direction of rotation arrow
  • type plate
  • identification of connections must be strictly observed and kept in an easily legible state

Personal qualification

  • The personnel used for mounting, operation, and maintenance must have relevant qualifications. The owner/operator must guarantee areas of responsibility and monitoring of personnel.
  • If personnel do not have the necessary knowledge, they must be trained or instructed accordingly.
  • This device can be used by children at or above the age of 8 years, as well as by persons with reduced physical, sensory, or mental capabilities, or who lack experience and knowledge, if they are supervised or have been instructed concerning the safe use of the device and if they understand the hazards arising from its use. Children may not play with the device. Cleaning and maintenance operations may not be conducted by children without supervision.

The danger of not observing safety instructions

  • Not observing the safety information can endanger persons, the environment, and the system.
  • Not observing the safety instructions shall result in the loss of all claims to warranty.

Potential dangers include:

  • Hazards to persons through electrical and mechanical effects.
  • Failure of important system functions.
  • Hazard to the environment from escaping fluids resulting from a leak.
  • Failure of prescribed repair and maintenance work.

Safety-conscious work

  • Observe the safety instructions detailed in this manual, along with the current national accident prevention regulations.
  • Should the system operator also have their own internal regulations, these must also be observed.

Safety instructions for the operator

  • Any existing touch guard protecting moving parts may be neither removed nor shut down while the system is in operation.
  • In the event of a fluid leak, any fluids must be collected or diverted in a way that prevents hazards to persons and the environment from arising.
  • Prevent hazards arising from electrical energy.
  • Observe the instructions in local or general regulations (e.g. IEC, VDE, etc.), and those of the local energy supplier.
  • In the event of hazards arising from the system due to contact with hot or cold parts, these parts must be fitted with a touch guard.
  • Keep flammable substances away from the product.

Safety instructions for installation and maintenance work

  • The system operator is responsible for ensuring that qualified personnel conduct all installation and maintenance work.
  • These persons must also have familiarised themselves in advance with the product using the operating instructions.
  • Conducting work on the pump is only permitted when the system has been isolated and has been allowed to cool.
  • Ensure that the device is securely disconnected from the power supply.
  • Disconnect the device plug to achieve this. Prescribed instructions for shutting down the device can be found in the operating instructions.
  • All protective mechanisms, such as a touch guard, must be correctly reattached after work.

Unauthorised conversion and production of spare parts

  • Modification or conversion of the product is only permitted after prior consultation with the manufacturer.
  • Only use original spare parts for repairs. Only use accessories that have been approved by the manufacturer.
  • The manufacturer shall bear no liability for any consequences resulting from the use of other parts.

Unpermitted operation

  • If the pump is disconnected from the power supply, wait at least 1 minute before reactivating.
  • Otherwise, the pump’s inrush current limit has no effect, which can lead to functional errors or damage to any connected heating controller.
  • The pump’s operational safety can only be ensured if it is used as intended.
  • Please observe section 3 of these operating instructions here.
  • Ensure compliance with the limit values detailed in the technical data.

Transport and storage

  • After receiving the product, inspect it immediately for damage caused in transport.
  • Should you detect any transport damage, assert a claim with the hauler.
  • Incorrect transport and storage can lead to personal injury or damage to the product.
  • Protect the product against frost, moisture, and damage during transport and storage.
  • Only carry the pump by the pump housing, and never by the connection cable or terminal box.
  • If the packaging weakens due to moisture, this can lead to the pump falling out and causing severe injury.

Intended Use

  • These high efficiency pumps are designed to circulate hot water in central heating systems and are also suitable for pumping low density liquids in industrial and commercial applications.
  • They are also suitable for solar installations.

Product information

Technical data Pulse Trade 25-60/130STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-1

Maximum elevation height 6.0 m
Maximum flow rate 3600 l/h
Power consumption P1 (W) 4.5 – 38
Supply voltage 1 x 230V 50Hz
Sound pressure level <43 dB(A)
EEI 0.20
Protection type IP 42
Temperature class TF 110
Ambient temperature 0 °C to 40 °C
Medium temperature +5 to110 °C
System pressure Max. 10 bar (1MPa)
Permitted media Heating water acc. to VDI 2035
Connection G1 ½”

Supply pressure

Medium temperature Minimum supply pressure
< 75 °C 0.05 bar 0.005 MPa 0.5 m
75 °C – 90 °C 0.3 bar 0.03 MPa 3.0 m
90 °C – 110 °C 1.1 bar 0.11 MPa 11.0 m

Acceptable range of application

Temperature range at maximum ambient temperature Permissible medium temperature
25 °C 5 °C to 110 °C
40 °C 5 °C to 95 °C

Attention!

  • The use of unsuitable media can destroy the pump and injure you.
  • It is necessary to observe the manufacturer’s information and safety data sheets!

Delivery range

  • Original assembly and operating manuals
  • Pump
  • 2 flat gaskets
  • Pump plug
  • Insulation

Pump description

  • In an average household, 10 to 20% of electricity consumption is used by conventional standard pumps.
  • We have developed a circulation pump with an energy efficiency index ≤ 0.20. By using Pulse Trade 25-60/130, energy consumption can be reduced by up to approx. 80% compared to a conventional circulation pump.
  • The hydraulic capacity can be kept almost the same as with the standard pumps. The pump capacity adapts to the actual system demand as it works according to the proportional pressure method.

Pump settings and capacity

Buttons

  • All pump functions can be controlled with just two buttons.
  • The buttonSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-2 switches the night reduction function on and off.
  • The buttonSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-3 controls the operating modes.
  • The selected operating mode is shown in the clear field of the LED indicator.

Service mode, setting the capacity rangeSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-4

  • The capacity range can be changed to 4m or 6m in service mode.
  • The pump must be disconnected from the 230V mains voltage for at least 15 seconds.
  • Connect the pump to the 230V mains voltage.
  • PressSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-3 theSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-2 buttons simultaneously within 3 seconds.
  • Then release both buttons.
  • Select the capacity range with the buttonSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-3.
  • -4 = 4m
  • -6 = 6m
  • The pump must be disconnected from the 230V mains voltage for at least 15 seconds.
  • Connect the pump to the 230V main voltage
  • The setting process is now complete. The pump is now running in the selected capacity range.
  • If necessary, the pump setting can be readjusted at any time.

Control panel and LED display

  1. Display of energy consumption in watts.
  2. Automatic night reduction display.
  3. Button for activating the automatic night reduction.
  4. Operating mode selection button.
  5. Display for activated AUTO Smartadapt mode.
  6. Display of the nine operating levels (characteristics) of the pump.STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-5
Selection of the operating mode and degree of work

Constant speed adjustment I, II, III

  • In this operating mode, the pump runs at a constant rotational speed over the entire characteristic curve.

Constant pressure adjustment CP 1, CP 2

  • In this type of adjustment, the pressure generated by the pump is kept at a constant level. This type of adjustment is especially suitable for use in underfloor heating systems.

Proportional pressure adjustment PP1, PP2

  • The pump is controlled by the proportional pressure method. In this case, the pressure generated by the pump is adapted to the changing flow rate. This operating mode is especially useful when the pump is to be used as a circulation pump for heating.

Smartadapt

  • The Smartadapt AUTO function is designed for two-circuit heating systems and underfloor heating systems.
  • The pump capacity is automatically adjusted to the actual heat demand of the installation.
  • The pump power is adjusted gradually and may take more than a week. If the power supply to the pump is interrupted, the pump remembers the last setting and resumes adjusting as soon as power is restored.
  • Upon delivery, the pump is set to the AUTO Smartadapt operating level. Multiple brief presses of the select button will continuously toggle between the constant speed, constant pressure, proportional pressure, and AUTO Smartadapt modes.
  • The selected operating mode is indicated by the appropriate LED with characteristic symbols. STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-6

Automatic night reduction display

  • DisplaySTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-7 means that automatic night reduction is activated.

Button for activating automatic night reduction

  • By pressing the buttonSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-2 in section 3, automatic night reduction is switched on or off.
  • When the automatic night reduction is activated, the symbolSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-7 lights up in the display field 3.
  • The “Automatic Night Reduction” function is not available in the constant speed levels.

Selection of the degree of work

  • Pressing the buttonSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-2 switches between the operating levels.

Recommendations for selecting a degree of workSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-8

  • Factory configuration = AUTO Smartadapt

Automatic night reduction of power Conditions for automatic night reduction:

  • Pumps installed in gas boilers with low water capacity must never be set to automatic night reduction.
  • If the heating system does not supply enough heat to the radiators, check whether the automatic night reduction function is active.
  • If necessary, deactivate the automatic night reduction function.
  • To ensure that night reduction functions properly, the following requirements must be met.
  1. The pump must be installed on the supply
  2. The heating system must be equipped with automatic temperature adjustment on the supply.

How automatic night reduction works

  • Press the button to activate the night reduction function. If the adjacent highlighted field is lit, the night reduction is activated and the pump automatically switches between normal operation and night reduction.
  • Switching depends on the flow temperature.
  • The pump automatically switches to night temperature reduction if the flow temperature drops by more than 10°-15°C in 1 hour.
  • Switching to normal operating mode takes place immediately as soon as the flow temperature rises again by 3°C.

Filling and venting the installation

  • Fill and vent the installation properly. To vent the pump, the electronics should be set to level III and operated in this position for at least 20 minutes.
  • Caution After this procedure, you can set the pump to the desired control mode.

Incomplete venting will cause noise in the pump and system

  • Warning! Danger of burns!
  • Depending on the operating status of the installation, the entire pump can become very hot.STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-9

Relationship between pump setting and capacity

The characteristic curves show the relationship between pump settings and pump capacity.STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-10

Capacity characteristics

STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-11

Installation

Correct installation position of the pumpSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-12

  • A voltage-free installation must be conducted with the pump motor in a horizontal position (the direction arrow on the pump body shows the direction of flow – ensure inlets/outlets are fitted correctly).
  • When performing thermal insulation, make sure that the pump and the electronics body are not insulated. If the installation position is to be changed, the pump must be rotated as follows.
  • Loosen the hexagon socket screws
  • Rotate the engine case
  • Re-screw and tighten the hexagon socket screws.

System dimensions

Dimensional sketch and dimension tableSTUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-13

Pump Type Dimensions Technical Data
H (mm) H1 (mm) L (mm) B (mm) G (“) Weight kg (without

cable)

Current (A) Elevation height (m)
Trade 25-60/130 138 112 130 93 1 ½ 2.12 0.04-0.25/0.04-0.31 0-4/0-6

Electrical Installation/Earthing

  • Regulations: The electrical installation must be carried out under the current local regulations by a qualified person.
  • Safety: In the interests of electrical safety a 30 mA residual current device (R.C.D. not supplied) should be installed in the supply circuit.
  • This may be part of a consumer unit or a separate unit.
  • Before starting work on the electrical supply ensure the power supply is isolated.
  • Earthing: This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in the terminal box.
  • Cable fitting: The pump must be factory-fitted supply cord and permanently connected to the fixed wiring of the main supply, via a dedicated double pole switched fused spur off the ring main.
  • DO NOT allow the supply cord to contact hot surfaces, including the motor shell, pump body, or pipework. The cord should be safely routed and secured by cable clips, alternatively, the cord must be protected by an insulating sleeving with an appropriate temperature rating.

Wiring of connection unit:

  • WARNING: This appliance must be earthed.
  • The wires in the mains lead (supply cord) are colored in accordance with the following code:
    • Green and Yellow: Earth (PE)
    • Blue: Neutral (N)
    • Brown: Live (L)
  • As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your connection unit proceed as follows:
  • The wire which is colored green and yellow must be connected to the terminal in the connection unit which is marked with the letters PE or by the earth symbol: or colored green or green and yellow.
  • The wire which is colored blue must be connected to the terminal which is marked with the letter N or colored black.
  • The wire which is colored brown must be connected to the terminal which is marked with the letter L or colored red.
  • Fuse: The pump MUST use a 5 Amp fuse.
  • Connect the power cord to the pump as shown in the below picture.
  • Caution mains voltage! Always observe the necessary safety measures, VDE regulations, and local regulations.STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-14

Caution Danger to life!

  • Incorrect installation and incorrect electrical connection can be life-threatening. Electricity hazards must be ruled out.
  • Installation and electrical connection may only be performed by qualified personnel and in accordance with the applicable regulations (e.g. IEC, VDE, etc.).
  • The type of current and voltage must comply with the data on the rating plate.
  • Comply with the regulations of the local power supply company.
  • Comply with the accident prevention regulations.
  • Never pull on the power cord.
  • Do not bend the cord.
  • Do not place any objects on the cord.
  • There is a risk of sharp and jagged edges during assembly.
  • Never transport by holding the power cord.
  • There is a risk of injury from dropping the pump.

Maintenance/service

  • Before carrying out maintenance, cleaning, and repair work, disconnect the system from the power supply and secure it against being switched on again by unauthorized persons.
  • At high water temperatures and system pressures, wait for the pump to cool down beforehand. There is a risk of burns!

Malfunctions, causes and elimination

Maintenance work or repair attempts may only be performed by qualified personnel. Before conducting maintenance, cleaning, and repair work, disconnect the system from the power supply and secure it against being switched on again by unauthorized persons. At high water temperatures and system pressures, wait for the pump to cool down beforehand. There is a risk of burns!STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-15 STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-16

  • If the defect cannot be eliminated, contact a specialized dealer.
  • After 10 seconds without pressing a button, the display turns off.
  • Pressing one of the two buttons turns it back on.

Disposal

  • The pump and its parts must not be disposed of with municipal waste but must be disposed of in an environmentally friendly manner!
  • To do this, use the services of public or private waste disposal companies.
  • You can find a list of the materials used in our products in the download area of our website.

Advice:

  • All illustrations in this manual are schematic representations. Please note that purchased electric pumps and accessories may differ from the illustrations in this manual.
  • Product performance is constantly improved and all products (including appearance and color, etc.) are subject to physical products; no notification will be given in the event of changes.

Warranty

PRODUCT WARRANTY TERMS & CONDITIONS

  • Congratulations on purchasing a Stuart Turner product We are confident this product will provide many years of trouble-free service as all our products are manufactured to the very highest standard.
  • All Pulse Trade 25-60/130 products are warranted to be free from defects in materials or workmanship for up to 5 years from the date of purchase.
  • Within the warranty period, we will repair, free of charge, any defects in the product resulting from faults in material or workmanship, repairing or exchanging the whole unit as we may reasonably decide.

Warranty Exclusions

  • Not covered by this warranty: Damage arising from incorrect installation, improper use, unauthorised repair, normal wear and tear, and defects that have a negligible effect on the value or operation of the pump.
  • This warranty is in addition to your statutory rights as a consumer. If you are in any doubt as to these rights, please contact your local Trading Standards Department.

Warranty Claim Procedure

  • In the event of a claim please telephone ‘TechAssist’ at +44 (0) 800 31 969 80 or email us at techassist@stuart-turner.co.uk
  • In the event of a claim within the terms of this warranty policy, your receipt or proof of purchase provided during registration will be reviewed.
  • You should obtain appropriate insurance coverage for any loss or damage which is not covered by Stuart Turner Ltd in this provision.

Please make a note for your reference:

PRODUCT MODEL SERIAL NO. DATE PURCHASED
     

STUART-TURNER-47505-Pulse-Trade-25-60-130-Circulating-Pump-FIG-17

Documents / Resources

STUART TURNER 47505 Pulse Trade 25-60 130 Circulating Pump [pdf] Instruction Manual
47505 Pulse Trade 25-60 130 Circulating Pump, 47505, Pulse Trade 25-60 130 Circulating Pump, 25-60 130 Circulating Pump, 130 Circulating Pump, Circulating Pump

References

Leave a comment

Your email address will not be published. Required fields are marked *