95101 Ford Flex 2011 Standard Key Remote Starters and Alarm Systems

Product Information: – Product Name: Immobilizer Bypass – Model
Number: Not specified – Compatibility: Ford Flex vehicles from 2009
to 2012 (40-bits) – Firmware Version: 71.[52] – Additional Tools
Required: FLASH LINK UPDATER or FLASH LINK MOBILE (sold separately)
– Parts Required (Not included): 1x 7.5 Amp. fuse, 2x 1Amp. Diodes
(with OEM alarm), 1x 1Amp. Diodes (without OEM alarm), THARNESS
THAR-FORD4, THARNESS THAR-FORD1 Product Usage Instructions: 1.
Firmware Update: To add the firmware version and options, use the
FLASH LINK UPDATER or FLASH LINK MOBILE tool, sold separately. 2.
Bypass Option Programming: – Select the desired bypass option: UNIT
OPTION OPTION UNITE – Available options: A5, C1, AUX.1 – If the
vehicle is not equipped with a functional hood pin (A11), set it to
OFF. – If the vehicle can be remote started with the hood open, set
function A11 to OFF. 3. Hood Pin Installation: – The installation
of safety elements is mandatory. – The hood pin is an essential
security element and must be installed. – If the vehicle is not
equipped with a functional hood pin, set A11 to OFF. – Hood Status:
The hood pin switch must be installed. 4. Qualified Technician
Installation: – This module must be installed by a qualified
technician. – Incorrect connections can cause permanent damage to
the vehicle. 5. Wiring Connection: – Ignition Barrel: Connect the
corresponding wires for (+) ACCESSORY, (+) START, (+) IGNITION,
(+)12V, (-)LOCK, (-)UNLOCK, (-)ARM, and (+)PARKING LIGHTS. – OBD-II
Connector: Connect the CAN HIGH (3) and CAN LOW wires. – T-Harness:
Connect the 12V BATTERY wire. Note that the T-Harness current is
limited to a maximum of 10 Amps. If the parking lights (+) require
more than 10 Amps, connect the remote starter’s power directly to
the vehicle’s battery with the appropriate fuse. If necessary,
connect the remote starter’s fused 12V power wire directly to the
T-Harness. – Wiring Connections: Connect the corresponding wires
for (-) HOOD, (-) HAND BRAKE, (-) TRUNK RELEASE, (+/-) TACHOMETER,
(+) FOOT BRAKE, (-) GROUND OUT WHILE RUNNING, (-) DOOR, (-) UNLOCK,
and (-) LOCK. Note: Refer to pages 3-5 of the user manual for
further wiring connections and diagrams. Please ensure that you
follow all instructions carefully and consult a qualified
technician if needed.

Immobilizer bypass Contournement d’immobilisateur T-harness available (Sold separately) Lock Unlock Arm Disarm RAP Disable Parking Lights Trunk Release Tachometer Door Status Trunk Status Hood Status* Hand-Brake Status Foot-Brake Status OEM Remote monitoring

ALL Page 1 / 12

REV.: 20220127

Guide # 95101

REGULAR, THAR-FOR4 & THAR-FOR1 INSTALLATION INSTALLATION RÉGULIÈRE, THAR-FOR1 ET THAR-FOR4

ADDENDUM – SUGGESTED WIRING CONFIGURATION ADDENDA – SCHÉMA DE BRANCHEMENT SUGGÉRÉ

“Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans ce diagramme (fonctionnelles si équipé)”

VEHICLE VEHICULES FORD
Flex

YEARS ANNÉES

40-bits 2009-2012

·

·

··············

FIRMWARE VERSION VERSION LOGICIELLE
71.[52] MINIMUM

To add the firmware version and the options, use the FLASH LINK UPDATER or FLASH LINK MOBILE tool, sold separately. Pour ajouter la version logicielle et les options, utilisez l’outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.

Program bypass option: Programmez l’option du contournement:

UNIT OPTION OPTION UNITE
A5

C1

IF THE VEHICLE IS NOT EQUIPPED

A11 WITH FUNCTIONAL HOOD PIN:
SI LE VÉHICULE N’EST PAS ÉQUIPÉ

OFF NON

D’UN CONTACT DE CAPOT FONCTIONNEL:

DESCRIPTION

AUX.1

ON

Par défaut with OEM alarm

OUI

Par défaut avec alarme

d’origine

OFF

AUX.1

NON

without OEM alarm sans alarme d’origine

OEM Remote status (Lock/Unlock) monitoring Suivi des status (Verrouillage/Déverrouillage) de la télécommande d’origine
Hood trigger (Output Status).

Contact de capot (état de sortie).

MANDATORY INSTALL | INSTALLATION OBLIGATOIRE

* HOOD PIN
CONTACT DE CAPOT

HOOD STATUS : THE HOOD PIN SWITCH MUST BE INSTALLED

IF THE VEHICLE CAN BE REMOTE STARTED WITH THE HOOD OPEN, A11

OFF NON

SET FUNCTION A11 TO OFF.

STATUT DE CAPOT : LE CONTACT DE CAPOT, DOIT ÊTRE INSTALLÉ SI LE

VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE CAPOT EST OUVERT,

PROGRAMMEZ LA FONCTION A11 À NON.

Notice: the installation of safety elements are mandatory. The hood pin is an essential security element and must be installed.

THIS MODULE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE.

Notice: l’installation des éléments de sécurité est obligatoire. Le contact de capot est un élément de sécurité essentiel et doit absolument être installé.

CE MODULE DOIT ÊTRE INSTALLÉ PAR UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
DESCRIPTION | DESCRIPTION

Parts required (Not included)

Pièce(s) requise(s) (Non incluse(s))

WIRE TO WIRE DIAGRAM | SCHÉMA DE BRANCHEMENTS FIL À FIL

1x 7.5 Amp. fuse 1x fuse 2x 1Amp. Diodes (with OEM alarm)
1x 1Amp. Diodes (without OEM alarm)

1x Fusible 7.5 Amp. 1x Fusible
2x Diodes 1 Amp. (avec alarme d’orgine)
1x Diodes 1 Amp. (sans alarme d’orgine)

THARNESS DIAGRAM | SCHÉMA DE BRANCHEMENTS HARNAIS EN T

THARNESS THAR-FORD4

1x THAR-FOR4 1x 7.5 Amp. fuse 2x 1Amp. Diodes (with OEM alarm)

1x THAR-FOR4 1x Fusible 7.5 Amp. 2x Diodes 1 Amp. (avec alarme d’orgine)

THARNESS THAR-FORD1

1x THAR-FOR1
1x 7.5 Amp. fuse 2x 1Amp. Diodes (with OEM alarm)
1x 1Amp. Diodes (without OEM alarm)

1x THAR-FOR1
1x Fusible 7.5 Amp. 2x Diodes 1 Amp. (avec alarme d’orgine)
1x Diodes 1 Amp. (sans alarme d’orgine)

Page 2 / 12
PAGE Page 3 Page 4 Page 5

Ignition barrel Barillet d’ignition
(+) ACCESSORY (+) START
(+) IGNITION (+)12V

BCM Driver side dash board BCM Tableau de bord côté chauffeur
DRIVER DOOR PIN
(-)LOCK
(-)UNLOCK

(-)ARM
(-)ARM (+)PARKING LIGHTS

OBD-II connector Connecteur OBD-II
CAN HIGH 3 11
CAN LOW

FLEX

(~) TX (~) RX
RX and TX of the module RX et TX du module
T-HARNESS: 12V BATTERY
ATTENTION THE T-HARNESS CURRENT IS LIMITED AT 10 AMP MAXIMUM.
If the parking lights (+) require more than 10Amp. connect the remote-starter’s power directly to the vehicles battery with the appropriate fuse.
Some remote starters can not be powered through Data-Link. In these cases connect the remote starter’s fused 12V power wire directly to the T-Harness.

HARNAIS EN T : 12V BATTERIE
ATTENTION LE COURANT DU 12V PROVENANT DU HARNAIS-EN-T EST LIMITÉ À 10 AMPÈRES MAXIMUM.
Si les lumières de stationnement (+) requièrent plus de 10 Ampères, branchez le 12V du démarreur à distance directement à la batterie du véhicule avec le fusible approprié.
Certains démarreurs à distance NE peuvent PAS être allimentés par le Data-Link. Dans ce cas, branchez le 12V (avec fusible) du démarreur à distance directement au harnais-en-T.

White/Orange Blanc/Orange Blue/Red Bleu/Rouge Purple/Green Mauve/Vert
A1
Blue/White Bleu/Blanc

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
WIRING CONNECTION | GUIDE DE BRANCHEMENTS

A15 (-) HOOD

IN RS8

A14 (-) HAND BRAKE

IN RS9

(-) TRUNK RELEASE

OUT RS11

A12 (+/-) TACHOMETER

IN RS12

A11 (+) FOOT BRAKE

IN RS13

A8 (-) GROUND OUT WHILE RUNNING OUT RS14

A4 (-) DOOR A3 (-) UNLOCK A2 (-) LOCK

IN RS16 OUT RS17 OUT RS18

WITH | AVEC DATA-LINK: ALWAYS REQUIRED TOUJOURS REQUIS

NOT REQUIRED WITH DATALINK NON REQUIS EN DATA-LINK

REMOTE STARTER DÉMARREUR À DISTANCE
WITH | AVEC DATA-LINK: Direct connection Branchement directe

RS7 OUT

STARTER (+)

RS6 IN/OUT

IGNITION (+)

RS5 OUT

ACCESSORY (+)

RS4 OUT PARKING LIGHTS (+)

RS2 IN

12V BATTERY (+)

RS1 Ground | Masse (-)

(+) Ignition

Yellow

(-) Lock

Purple

(-) Unlock Purple/White

(-) Door/Trunk Status

Green

UNLOCK

White

Orange

Orange/Black

(-) Ground While Running

Dk.Blue

(+)Start

Red/Blue

RX Lt.Blue/Black

(+) Foot Brake

Black

(-/+) Tachometer

Pink

Yellow/Black

(-) Hand Brake Brown/White

(-) Hood Status Pink/Black

Purple/Yellow

Driver Door (Vehicle side) Green/White

Driver Door (Con. side) Green/Red

LOCK White/Black

TX

Lt.Blue

B In AA11

In AA22

In AA33

Out AA44 Out AA55
In AA66
A In AA77
In AA88 In AA99
A1100 Out AA1111 Out A1122
In AA1133 Out AA1144 Out AA1155
A1166

C55 Brown

CC44 Gray/Black

CAN LOW

CC33 Gray

CAN HIGH

C C22 Orange/Brown

CC11 Orange/Green

D6 White/Red
D DD55 White/Blue
D4 White/Green D33 Yellow/Red DD22 Yellow/Blue DD11 Yellow/Green

(+)Ignion
(+)12V
Connection required when programming with two (2) Key. Branchements requis pour programmation avec deux (2) clés.

A1177 OPTIONAL CONNECTION REQUIRED TO ARM THE

A1188 FACTORY ALARM WHEN THE DOORS ARE LOCKED

A1199

AND RAP CONTROL. I OPTIONNEL BRANCHEMENTS REQUIS POUR ARMER L’ALARME

AA2200 D’ORIGINE LORSQUE LES PORTES SONT

VERROUILLÉES ET POUR LE CONTRÔLE DU RAP.

Page 3 / 12
A9

7.5 AMP.
Fuse Fusible

WITHOUT OEM ALARM SANS ALARM D’ORIGINE

OR OU

WITH OEM ALARM AVEC ALARM D’ORIGINE

A19

A17 CUT

1Amp Diode
1AMP. Diode 1AMP. Diode

RS10

RS4

A19

(-)TRUNK (+)PARKING (-)

(-)

RELEASE LIGHT

LOCK ARM

(-) ARM

A5

A18

(-)

DRIVER

UNLOCK DOOR PIN

C3

C4

CAN CAN

HIGH LOW

A10

A20

RX TX

Fuse Fusible

RS6/A1

RS2/D5

(+) Ignition (+)12V

D6

RS8

(+) Accessory

(+)Start

Gray/Orange Gris/Orange Violet/Orange Violet/Orange

Green/Violet Vert/Violet

Purple/White Mauve/Blanc Blue/Green Bleu/Vert Purple/Green Mauve/Vert Yellow/Green Jaune/Vert
Yellow/Violet Jaune/Violet

Grey/Yellow Gris/Jaune

FLEX

123 456

1234567

8 9 10

11 12 13

13 12 11 10 9 8 7 6 5 4 3 2 1 26 25 24 23 22 21 20 19 18 17 16 15 14

1 2 33 4 5 6 7 8 1111 9 10 11 12 13 14 15 16

43 21

1 23

4

56 7

4A

Trunk or hatch switch. Commutateur de la valise ou du hayon.

BCM Driver side dash board Gray connector (10-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Gris (10-pins) Vue de dos

4B
BCM Driver side dash board Black
connector (26-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Noir (26-pins) Vue de
dos

12345 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

3

2

B

OBD-II At ignition barrel Transponder

connector connector Black connector

31

30

28 29

17 18 19 20 21 22 23 24 25 26

7 8 9 10 11 12 13 14 15 16

6

5

34

Front view

(4-pins) Back view

27

2

26

1

A

Connecteur Au barillet d’ignition connecteur

OBD-II

du transpondeur. Connecteur

Vue de face

Noir (4-pins) Vue de dos

Ignition barrel Barillet de l’ignition

4

1
At ignition barrel Black ignition connector (8-pins) Back view
Au barillet d’ignition connecteur noir d’ignition (8-pins) Vue de dos

4

21

3

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
THAR-FOR4 – INSTALLATION WIRING | SCHÉMA DE BRANCHEMENT

Page 4 / 12

A15 (-) HOOD

IN RS8

A14 (-) HAND BRAKE

IN RS9

(-) TRUNK RELEASE

OUT RS11

A12 (+/-) TACHOMETER

IN RS12

A11 (+) FOOT BRAKE

IN RS13

A8 (-) GROUND OUT WHILE RUNNING OUT RS14

REMOTE STARTER DÉMARREUR À DISTANCE

A4 (-) DOOR A3 (-) UNLOCK A2 (-) LOCK
ALWAYS REQUIRED TOUJOURS REQUIS
NOT REQUIRED WITH DATALINK NON REQUIS EN DATA-LINK

IN RS16 OUT RS17 OUT RS18

WITH DATA-LINK: AVEC DATA-LINK:

OR OU

WITH | AVEC DATA-LINK: Direct connection
Branchement directe

WITH D2D: AVEC D2D:

WITHOUT SANS DATA-LINK:

RS7 OUT

STARTER (+) A9

RS6 IN/OUT

IGNITION (+)

RS4 OUT PARKING LIGHTS (+)

RS2 IN

12V BATTERY (+)

RS1 Ground | Masse (-)

Cut | Coupez Red 12V BATTERY Cut | Coupez Black GROUND

ATTENTION THE T-HARNESS CURRENT IS LIMITED AT 10 AMP MAXIMUM.

ATTENTION LE COURANT DU 12V PROVENANT DU HARNAIS-EN-T EST LIMITÉ À 10 AMPÈRES MAXIMUM.

If the parking lights Si les lumières de

(+) require more than stationnement (+)

10Amp. connect the requièrent plus de 10

remote-starter’s

Ampères, branchez le 12V

power directly to the du démarreur à distance

vehicles battery with directement à la batterie du

the appropriate fuse. véhicule avec le fusible

approprié.

Some remote starters

can not be powered Certains démarreurs à

through Data-Link. In distance NE peuvent PAS

these cases connect être allimentés par le

the remote starter’s Data-Link. Dans ce cas,

fused 12V power wire branchez le 12V (avec

directly to the

fusible) du démarreur à

T-Harness.

distance directement au

harnais-en-T.

Use the DATA-LINK cable supplied
wih the module. Ulisez le câble DATA-LINK inclus avec le module.

(+) Ignition

Yellow

(-) Lock

Purple

(-) Unlock Purple/White

(-) Door/Trunk Status

Green

UNLOCK

White

Orange

Orange/Black

(-) Ground While Running

Dk.Blue

(+)Start

Red/Blue

RX Lt.Blue/Black

(+) Foot Brake

Black

(-/+) Tachometer

Pink

Yellow/Black

(-) Hand Brake Brown/White

(-) Hood Status Pink/Black

Purple/Yellow

Driver Door (Vehicle side) Green/White

Driver Door (Con. side) Green/Red

LOCK White/Black

TX

Lt.Blue

B
In AA11
In AA22
In AA33

A1/RS6

(+)IGNITION

KEY SENSE

NOT CONNECTED | NE PAS BRANCHER

IMMO POWER
NOT CONNECTED | NE PAS BRANCHER

Yellow Purple/Yellow
Orange/White

Out AA44
Out AA55
In AA66
A In AA77
In AA88
In AA99

C55 Brown CC44 Gray/Black CC33 Gray
C C22 Orange/Brown CC11 Orange/Green

5 PIN CONN.

A1100 Out AA1111 Out A1122
In AA1133 Out AA1144 Out AA1155
A1166

D6 White/Red
D DD55 White/Blue
D4 White/Green D33 Yellow/Red DD22 Yellow/Blue DD11 Yellow/Green

NOT CONNECTED | NE PAS BRANCHER

A1177 OPTIONAL CONNECTION REQUIRED TO ARM THE

A1188 FACTORY ALARM WHEN THE DOORS ARE LOCKED

A1199

AND RAP CONTROL. I OPTIONNEL BRANCHEMENTS REQUIS POUR ARMER L’ALARME

AA2200 D’ORIGINE LORSQUE LES PORTES SONT

VERROUILLÉES ET POUR LE CONTRÔLE DU RAP.

NOT CONNECTED NE PAS BRANCHER

A

4 PINS

7.5 AMP.
Fuse Fusible

WITHOUT OEM ALARM SANS ALARM D’ORIGINE

OR OU

WITH OEM ALARM AVEC ALARM D’ORIGINE

A19

A17 CUT

1Amp Diode
1AMP. Diode 1AMP. Diode

RS10

RS4

A19

(-)TRUNK (+)PARKING (-)

(-)

RELEASE LIGHT

LOCK ARM

(-) ARM

A5

A18

(-)

DRIVER

UNLOCK DOOR PIN

6 PINS
B

T-HARNESS – HARNAIS EN T
THAR-FORD4

Green/Violet Vert/Violet

Purple/White Mauve/Blanc Blue/Green Bleu/Vert Purple/Green Mauve/Vert Yellow/Green Jaune/Vert
Yellow/Violet Jaune/Violet

Grey/Yellow Gris/Jaune

FLEX

123 456

1234567

8 9 10

11 12 13

13 12 11 10 9 8 7 6 5 4 3 2 1 26 25 24 23 22 21 20 19 18 17 16 15 14

4A

Trunk or hatch switch. Commutateur de la valise ou du hayon.

BCM Driver side dash board Gray connector (10-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Gris (10-pins) Vue de dos

4B
BCM Driver side dash board Black
connector (26-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Noir (26-pins) Vue de
dos

12345 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

B

OBD-II

At ignition barrel

connector Transponder connector Black

31

30

28 29

17 18 19 20 21 22 23 24 25 26

7 8 9 10 11 12 13 14 15 16

6

5

34

27

2

26

1

A

Front view

connector (6-pins) Back view Au barillet d’ignition

Connecteur connecteur du transpondeur.

OBD-II

Connecteur Noir (6-pins) Vue

Vue de face

de dos

4

At ignition barrel Black ignition connector (8-pins) Back view
Au barillet d’ignition connecteur noir d’ignition (8-pins) Vue de dos
4

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
THAR-FOR1 – INSTALLATION WIRING | SCHÉMA DE BRANCHEMENT

A15 (-) HOOD

IN RS8

A14 (-) HAND BRAKE

IN RS9

(-) TRUNK RELEASE

OUT RS11

A12 (+/-) TACHOMETER

IN RS12

A11 (+) FOOT BRAKE

IN RS13

A8 (-) GROUND OUT WHILE RUNNING OUT RS14

A4 (-) DOOR A3 (-) UNLOCK A2 (-) LOCK
ALWAYS REQUIRED TOUJOURS REQUIS
NOT REQUIRED WITH DATALINK NON REQUIS EN DATA-LINK

IN RS16 OUT RS17 OUT RS18

WITH DATA-LINK:

AVEC DATA-LINK:

OR

OU

WITH D2D: AVEC D2D:

WITHOUT DATA-LINK: SANS DATA-LINK:

REMOTE STARTER DÉMARREUR À DISTANCE

RS7 OUT

STARTER (+) A9

RS6 IN/OUT

IGNITION (+)

RS4 OUT PARKING LIGHTS (+)

RS2 IN

12V BATTERY (+)

RS1 Ground | Masse (-)

WITH | AVEC DATA-LINK: Direct connection Branchement directe
Cut | Coupez Cut | Coupez

B4
B3
Red Black B4
B3
Blue B2 B2
White B1 B1

Red Black

12V Battery Ground

Fuse Fusible

Page 5 / 12

ATTENTION THE T-HARNESS CURRENT IS LIMITED AT 10 AMP MAXIMUM.
If the parking lights (+) require more than 10Amp. connect the remote-starter’s power directly to the vehicles battery with the appropriate fuse.

ATTENTION LE COURANT DU 12V PROVENANT DU HARNAIS-EN-T EST LIMITÉ À 10 AMPÈRES MAXIMUM.
Si les lumières de stationnement (+) requièrent plus de 10 Ampères, branchez le 12V du démarreur à distance directement à la batterie du véhicule avec le fusible approprié.

Some remote starters can not be powered through Data-Link. In these cases connect the remote starter’s fused 12V power wire directly to the T-Harness.

Certains démarreurs à distance NE peuvent PAS être allimentés par le Data-Link. Dans ce cas, branchez le 12V (avec fusible) du démarreur à distance directement au harnais-en-T.

(+) Ignition

Yellow

(-) Lock

Purple

(-) Unlock Purple/White

(-) Door/Trunk Status

Green

UNLOCK

White

Orange

Orange/Black

(-) Ground While Running

Dk.Blue

(+)Start

Red/Blue

RX Lt.Blue/Black

(+) Foot Brake

Black

(-/+) Tachometer

Pink

Yellow/Black

(-) Hand Brake Brown/White

(-) Hood Status Pink/Black

Purple/Yellow

Driver Door (Vehicle side) Green/White

Driver Door (Con. side) Green/Red

LOCK White/Black

TX

Lt.Blue

A1/RS6 (+)IGNITION

Yellow

B
In AA11 In AA22 In AA33 Out AA44 Out AA55 In AA66
A In AA77
In AA88 In AA99
A1100 Out AA1111 Out A1122
In AA1133 Out AA1144 Out AA1155
A1166

20 PIN CONN.
Use the connector supplied with the unit. Utilisez le connecteur fourni avec le module.

A20

Lt.Blue

A10

Lt.Blue/Black

Yellow/Black
NOT CONNECTED | NE PAS BRANCHER

C55 Brown

CC44 Gray/Black

CAN LOW

CC33 Gray

CAN HIGH

C C22 Orange/Brown

CC11 Orange/Green

5 PIN CONN.
Use the connector supplied with the unit. Utilisez le connecteur fourni avec le module.

D6 White/Red
D DD55 White/Blue
D4 White/Green D33 Yellow/Red DD22 Yellow/Blue DD11 Yellow/Green

NOT CONNECTED | NE PAS BRANCHER

A1177 OPTIONAL CONNECTION REQUIRED TO ARM THE

A1188 FACTORY ALARM WHEN THE DOORS ARE LOCKED

A1199

AND RAP CONTROL. I OPTIONNEL BRANCHEMENTS REQUIS POUR ARMER L’ALARME

AA2200 D’ORIGINE LORSQUE LES PORTES SONT

VERROUILLÉES ET POUR LE CONTRÔLE DU RAP.

T-HARNESS – HARNAIS EN T
THAR-FORD1

7.5 AMP.
Fuse Fusible

WITHOUT OEM ALARM SANS ALARM D’ORIGINE

OR OU

WITH OEM ALARM AVEC ALARM D’ORIGINE

A19

A17 CUT

1Amp Diode
1AMP. Diode 1AMP. Diode

RS10

RS4

A19

(-)TRUNK (+)PARKING (-)

(-)

RELEASE LIGHT

LOCK ARM

(-) ARM

A5

A18

(-)

DRIVER

UNLOCK DOOR PIN

C3

C4

CAN CAN

HIGH LOW

4 PINS

Gray/Orange Gris/Orange Violet/Orange Violet/Orange

Green/Violet Vert/Violet

Purple/White Mauve/Blanc Blue/Green Bleu/Vert Purple/Green Mauve/Vert Yellow/Green Jaune/Vert
Yellow/Violet Jaune/Violet

Grey/Yellow Gris/Jaune

FLEX

123 456

1234567

8 9 10

11 12 13

13 12 11 10 9 8 7 6 5 4 3 2 1 26 25 24 23 22 21 20 19 18 17 16 15 14

1 2 33 4 5 6 7 8 1111 9 10 11 12 13 14 15 16

4A

Trunk or hatch switch. Commutateur de la valise ou du hayon.

BCM Driver side dash board Gray connector (10-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Gris (10-pins) Vue de dos

4B
BCM Driver side dash board Black
connector (26-pins) Back view BCM Tableau de bord côté chauffeur Connecteur Noir (26-pins) Vue de
dos

12345 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

3

5

6

B

30

31

OBD-II connector

At ignition barrel Transponder connector Black

28 29

34

Front view connector (4-pins) Back view

27

2

17 18 19 20 21 22 23 24 25 26

7 8 9 10 11 12 13 14 15 16

26

1

A

Connecteur OBD-II

Au barillet d’ignition connecteur du transpondeur.

Vue de face Connecteur Noir (4-pins) Vue

de dos

4

At ignition barrel Black ignition connector (8-pins) Back view
Au barillet d’ignition connecteur noir d’ignition (8-pins) Vue de dos
4 3

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.

Page 6 / 12

KEY BYPASS PROGRAMMING PROCEDURE 1/2 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 1/2

KEY#1 KEY#2 CLÉ#1 CLÉ#2

2 key programming. Programmation avec 2 clés.

Choose between :

Choisir entre:

KEY#1 CLÉ#1

DCRYPTOR and 1 key programming. Programmation avec

DCRYPTOR et 1 clé.

2 KEY REQUIRED 2 CLÉS REQUISES
KEY#1 KEY#2 CLÉ#1 CLÉ#2
1

x1
HOLD
2

LED may differ depending on the module casing. L’apparence des DELS peut différer selon le boîtier du module.

RELEASE

ON

RED ROUGE

3

Press and hold the programming button: Connect the 4-PIN Data-link harness (Black connector).
9 The Blue, Red, Yellow and Blue & Red LEDs will alternatively illuminate.

Appuyez et maintenir enfoncé le bouton de programmation: Branchez le harnais Data-Link à 4-Broches (connecteur Noir)
9 Les DELs Bleue, Rouge, Jaune et Bleue & Rouge s’allumeront alternativement.

Release the programming button when the LED is RED.

Relâchez le bouton de programmation quand la DEL est ROUGE.

If the LED is not solid RED

Si le DEL n’est pas ROUGE

disconnect the 4 Pin

solide débranchez le

connector (Data-Link) and go

connecteur 4 pins (Data-Link)

E O ALL

back to step 1.

et allez à l’étape 1.

Insert the required remaining Insérez les connecteurs requis

connectors.

restants.

4
TURN ON/RUN
KEY#1 CLÉ#1
5
TURN OFF

LOCK

LOCK

ACC ON

IGN

START

PUSH

WAIT 3 SEC.

IGN ON
ACC ON

LOCK

START

START

OFF
ACC ON PUSH

REMOVE KEY

ACC ON PUSH

LOCK

START

Turn the first functional key to the Ignition ON/RUN position.
Wait 3 seconds.

Tournez la première clé fonctionelle à Ignition.
Attendre 3 secondes.

Turn the key to the OFF position.
Remove the first key.

Tournez la clé à la position Arrêt (OFF).
Retirez la clé du contact.

CONTINUED NEXT PAGE | CONTINUEZ À LA PAGE SUIVANTE

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.

Page 7 / 12

KEY BYPASS PROGRAMMING PROCEDURE 2/2 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 2/2

6

TURN ON/RUN
KEY#2 CLÉ#2
7

LOCK

ACC ON

IGN

START

PUSH

WAIT 3 SEC.

LOCK

START

IGN ON
ACC ON

Turn the second functional key to the Ignition ON/RUN position.
Wait 3 seconds.

Tournez la deuxième clé fonctionelle à Ignition.
Attendre 3 secondes.

TURN OFF

LOCK

START

OFF
ACC ON PUSH

REMOVE KEY

ACC ON PUSH

LOCK

START

8
CAUTION The following step must
be completed within 5 seconds.
Otherwise disconnect all connectors 5 sec. max and go back to step 1.

Turn the key to the OFF position.
Remove the second key.

Tournez la clé à la position Arrêt (OFF)
Retirez la deuxième clé du barillet d’alimentation.

ATTENTION les prochaines étapes doivent être complétées en moins de 5 secondes. Si non, débranchez tous les connecteurs et allez à l’étape 1.

x1
PRESS

Ignition ON

Press and release the programming button.

Pesez et relâchez le bouton de programmation.

The vehicle ignition turn ON.

L’ignition du véhicule s’allume.

IGNITION ON

FLASH 10X

FLASH 10X FLASH

Ignition OFF

The RED LED will flash rapidly 10x times. Key bypass programmed.
The BLUE LED will flash rapidly. CAN-Bus programmed.
If the LED is solid RED disconnect the 4 Pin connector (Data-Link) and go back to step 1.

La DEL ROUGE clignotera 10x fois rapidement. Contournement de clé programmé.
La DEL BLEU clignotera rapidement: Réseau CAN programmé.
Si le DEL est ROUGE solide débranchez le connecteur 4 pins (Data-Link) et allez à l’étape 1.

The vehicle ignition will turn OFF.

L’ignition du véhicule s’éteins.

The module is now programmed.
Use the remote of the remote starter or security system to test all of the supported features to ensure proper programming.

Le module est programmé.
Testez toutes les fonctions supportées sur le véhicule avec la télécommande du démarreur à distance ou du système de sécurité.

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
DCRYPTOR PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION AVEC DCRYPTOR

Page 8 / 12

Parts required (not included) Pièces requises (non incluses)

1x FLASH LINK UPDATER,

1x FLASH LINK MOBILE

1x FLASH LINK MANAGER

OR

SOFTWARE | PROGRAMME

OU

1x

Microsoft Windows Computer with Internet connection Ordinateur Microsoft Windows avec connection Internet

1x FLASH LINK MOBILE APP

Smartphone Android or iOS with Internet connection

1x

(Internet provider charges may apply)
Téléphone Intelligent Android ou iOS avec connection

Internet (des frais du fournisseur Internet peuvent s’appliquer)

BEFORE PROGRAMMING SET THE UNIT OPTIONS AND SAVE. | AVANT LA PROGRAMMATION CONFIGURER LES OPTIONS DE L’UNITÉ ET SAUVEGARDER.

1

x1
HOLD

LED may differ depending on the module casing. L’apparence des DELS peut différer selon le boîtier du module.

Press and hold the

Appuyez et maintenir

programming button: Insert the 4-Pin (Data-Link)

enfoncé le bouton de programmation:

connector.

Insérez le connecteur 4 pins (Data-Link)

The Blue, Yellow, Red and Blue & Red LEDs will alternatively illuminate.

Les DELs Bleue, Jaune, Rouge et Bleue & Rouge illumineront alternativement.

2

RELEASE
3

ON

RED ROUGE

Release the programming button when the LED is RED.

Relâchez le bouton de programmation quand la DEL est ROUGE.

If the LED is not solid RED disconnect the 4-Pin connector (Data-Link) and go back to step 1.

Si la DEL n’est pas ROUGE débranchez le connecteur 4 pins (Data-Link) et allez au début de l’étape 1.

Insert the required remaining connectors.

Insérez les connecteurs requis restants.

4
x1
PRESS

PRESS X1

OFF

ON

ON

OFF

ON

Press and release the

Appuyez et relâchez 1 fois le

programming button once (1x). bouton de programmation.

The RED LED will flash once.

La DEL ROUGE clignote 1 fois.

5

IGN
ON

LOCK

ACC ON

IGN

START

PUSH

IGNITION OFF IGNITION ON

ON

ON

OFF

Turn the key to the Ignition ON/RUN position.
The RED LED will turn OFF.
The YELLOW LED will turn on.

Tournez la clé à Ignition.
La DEL ROUGE s’éteint. La DEL JAUNE s’allume.

CONTINUED NEXT PAGE | CONTINUEZ À LA PAGE SUIVANTE

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.

Page 9 / 12

KEY BYPASS PROGRAMMING PROCEDURE 2/3 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 2/3

6 IGN
OFF

LOCK

START

OFF
ACC ON PUSH

IGNITION ON

IGNITION OFF

ON

OFF

Turn the key to the OFF position Remove the key from th.e ignition barrel.

Fermez la clé de contact. Retirer la clé du barillet d’ignition.

The YELLOW LED will turn OFF.

La DEL JAUNE s’éteint.

REMOVE KEY

ACC ON PUSH

LOCK

7 IGN
ON

LOCK

ACC ON

IGN

START

PUSH

8 IGN
OFF

LOCK

START

OFF
ACC ON PUSH

REMOVE KEY

ACC ON PUSH

LOCK

9
TURN ON/RUN

LOCK

ACC ON

IGN

START

PUSH

10
TURN OFF

LOCK

START

OFF
ACC ON PUSH

REMOVE KEY

ACC ON PUSH

LOCK

START

START

START

ON

The RED LED will turn on.

La DEL ROUGE s’allume.

IGNITION OFF IGNITION ON

ON

ON

OFF

Turn the key to the Ignition ON/RUN position.
The RED LED will turn OFF.
The YELLOW LED will turn on.

Tournez la clé à Ignition.
La DEL ROUGE s’éteint. La DEL JAUNE s’allume.

IGNITION ON

IGNITION OFF

ON

OFF

Turn the key to the OFF position Remove the key from th.e ignition barrel.

Fermez la clé de contact. Retirer la clé du barillet d’ignition.

The YELLOW LED will turn OFF.

La DEL JAUNE s’éteint.

The RED LED will turn on.

La DEL ROUGE s’allume.

ON

IGNITION OFF IGNITION ON

ON

OFF

ON

OFF

FLASH

Turn the key to the Ignition ON/RUN position.
The YELLOW LED will turn on and off.
The RED LED will turn OFF.

Tournez la clé à Ignition.
La DEL JAUNE s’allume et s’éteint. La DEL ROUGE s’éteint.

WAIT, the BLUE LED to flash rapidly.

ATTENDRE que la DEL BLEUE clignote rapidement.

IGNITION OFF FLASH RAPIDLY
ON ON

Turn the key to the OFF position Remove the key from th.e ignition barrel.
The RED and YELLOW LEDs will alternate.

Fermez la clé de contact. Retirer la clé du barillet d’ignition.
La DEL ROUGE et JAUNE alternent.

CONTINUED NEXT PAGE | CONTINUEZ À LA PAGE SUIVANTE

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.

Page 10 / 12

KEY BYPASS PROGRAMMING PROCEDURE 3/3 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 3/3

11

EVO-ALL
Disconnect all the connectors and after the Data-Link (4-pins) connector.
Débranchez tous les connecteurs et ensuite le connecteur Data-Link (4-pins).

12

FLASH LINK UPDATER*
OR OU

13

VEHICLE’S OBDII CONNECTOR
CONNECTEUR OBDII DU VÉHICULE

FLASH LINK MOBILE*

Microsoft Windows Computer with Internet connection*
Ordinateur Microsoft Windows avec connection Internet*
FLASH LINK MANAGER*
SOFTWARE | PROGRAMME
Smartphone*
(Internet provider charges may apply)
Téléphone Intelligent*
(des frais du fournisseur Internet peuvent s’appliquer)

Use the tool: FLASH LINK UPDATER or FLASH LINK MOBILE to visit the DCryptor menu.

Utilisez l’outil: FLASH LINK UPDATER ou FLASH LINK MOBILE pour visiter le menu DCryptor.

*Parts required (not included) *Pièces requises (non incluses)

AFTER DCRYPTOR PROGRAMMING COMPLETED

Go back to the vehicle and reconnect the 4-Pin (Data-Link)

EVO-ALL

connector and after, all the remaining connector.

APRÈS LA PROCÉDURE DE PROGRAMMATION DCRYPTOR COMPLETÉE : retournez au véhicule et rebranchez le connecteur 4-pins (Data-Link) et après, tous les connecteurs du EVO-ALL.

The module is now programmed. Le module est programmé.

REMOTE STARTER / ALARM VERIFICATION PROCEDURE | PROCÉDURE DE VÉRIFICATION DU DÉMARREUR À DISTANCE / ALARME
Test the remote starter. Remote start the vehicle. Testez le démarreur à distance. Démarrez le véhicule à distance.

This guide may change without notice. See www.fortin.ca for latest version. Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version.
REMOTE STARTER FUNCTIONALITY | FONCTIONNALITÉS DU DÉMARREUR À DISTANCE

Page 11 / 12

Start

UNLOCK

TURN ON/RUN

ON

All doors must be closed. Toutes les
portes doivent être fermées.

Remote start the vehicle.
Démarrez à distance.

Unlock the doors with the remote-starter remote or the OEM remote.
Déverrouillez les portes avec la télécomande du démarreur à distance ou
la télécommande d’origine.

Insert and Turn the key to the Ignition ON/RUN
position. Insérez et tournez la clé à la position “ON/RUN”.

Press the brake pedal.
Appuyez sur la pédale de
frein.

The vehicle can now be put in to gear and driven.
Vous êtes maintenant prêt à
embrayer et prendre la route.

Page 12 / 12

ALL

HARDWARE VERSION FIRMWARE VERSION
Date: xx-xx
EVO-ALL
INTERFACE MODULE
PATENTS PENDING US: 2007-228827-A1
Made in Canada www.fortinbypass.com
Service No : 000 102 04 2536
Module label | Étiquette sur le module

Notice: Updated Firmware and Installation Guides Updated firmware and installation guides are posted on our web site on a regular basis. We recommend that you update this module to the latest firmware and download the latest installation guide(s) prior to the installation of this product.
Notice: Mise à jour microprogramme et Guides d’installations Des mises à jour du Firmware (microprogramme) et des guides d’installation sont mis en ligne régulièrement. Vérifiez que vous avez bien la dernière version logiciel et le dernier guide d’installation avant l’installation de ce produit.

WARNING The information on this sheet is provided on an (as is) basis with no representation or warranty of accuracy whatsoever. It is the sole responsibility of the installer to check and verify any circuit before connecting to it. Only a computer safe logic probe or digital multimeter should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or responsibility whatsoever pertaining to the accuracy or currency of the information supplied. The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way. Neither the manufacturer or distributor of this module is responsible of damages of any kind indirectly or directly caused by this module, except for the replacement of this module in case of manufacturing defects. This module must be installed by qualified technician. The information supplied is a guide only. This instruction guide may change without notice. Visit www.fortinbypass.com to get the latest version.
MISE EN GARDE L’information de ce guide est fournie sur la base de représentation (telle quelle) sans aucune garantie de précision et d’exactitude. Il est de la seule responsabilité de l’installateur de vérifier tous les fils et circuits avant d’effectuer les connexions. Seuls une sonde logique ou un multimètre digital doivent être utilisés. FORTIN SYSTÈMES ÉLECTRONIQUES n’assume aucune responsabilité de l’exactitude de l’information fournie. L’installation (dans chaque cas) est la responsabilité de l’installateur effectuant le travail. FORTIN SYSTÈMES ÉLECTRONIQUES n’assume aucune responsabilité suite à l’installation, que celle-ci soit bonne, mauvaise ou de n’importe autre type. Ni le manufacturier, ni le distributeur ne se considèrent responsables des dommages causés ou ayant pu être causés, indirectement ou directement, par ce module, excepté le remplacement de ce module en cas de défectuosité de fabrication. Ce module doit être installé par un technicien qualifié. L’information fournie dans ce guide est une suggestion. Ce guide d’instruction peut faire l’objet de changement sans préavis. Consultez le www.fortinbypass.com pour voir la plus récente version.
Copyright © 2006-2018, FORTIN AUTO RADIO INC ALL RIGHTS RESERVED PATENT PENDING

TECH SUPPORT Tél: 514-255-HELP (4357)
1-877-336-7797
ADDENDUM GUIDE

www.fortinbypass.com
WEB UPDATE | MISE À JOUR INTERNET

Documents / Resources

FORTIN 95101 Ford Flex 2011 Standard Key Remote Starters and Alarm Systems [pdf] Installation Guide
95101 Ford Flex 2011 Standard Key Remote Starters and Alarm Systems, 95101, Ford Flex 2011 Standard Key Remote Starters and Alarm Systems, Remote Starters and Alarm Systems, and Alarm Systems, Alarm Systems

References

Leave a comment

Your email address will not be published. Required fields are marked *