FORTIN-LOGO

FORTIN 94851 2012 Ford Explorer Regular Key Remote Starters and Alarm Systems

FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-PRODUCT

Product Information

  • Product Name: Vehicle Remote Starter
  • Model: Ford Explorer 80-bits (SA KEY) 2011-2015
  • Firmware Version: 71.[52]
  • Manufacturer: Ford

Description

The Vehicle Remote Starter is a device that allows users to start their Ford Explorer remotely. It is compatible with Ford Explorer models from 2011 to 2015 with SA KEY (80-bits). The device requires installation by a qualified technician to ensure proper functionality and prevent any damage to the vehicle.

Parts Required (Not Included)

  • 1x 7.5 Amp. fuse
  • 1x 1 Amp. Diode
  • 1x THAR-FORD4 T-Harness
  • 1x THAR-FORD1 T-Harness

Wiring Connections

The Vehicle Remote Starter needs to be connected to various components of the vehicle for proper operation. The user manual provides detailed instructions on how to make the necessary wiring connections.

Important Safety Information

The installation of safety elements is mandatory for the proper functioning of the Vehicle Remote Starter. The hood pin switch is an essential security element and must be installed. Incorrect connections can cause permanent damage to the vehicle, so it is crucial to have the device installed by a qualified technician.

Product Usage Instructions

  1. Ensure that all required parts, including the 7.5 Amp. fuse, 1 Amp. Diode, THAR-FORD4 T-Harness, and THAR-FORD1 T-Harness, are available.
  2. Refer to the wiring diagram provided in the user manual to identify the appropriate connections for the Vehicle Remote Starter.
  3. Follow the wiring instructions carefully to connect the Vehicle Remote Starter to the ignition barrel, driver door pin, parking lights, OBD-II connector, and other relevant components.
  4. Pay special attention to the connection of the hood pin switch. It is mandatory to install the hood pin switch for proper operation.
  5. Ensure that all connections are secure and properly insulated to prevent any electrical issues.
  6. If the parking lights require more than 10 Amp., connect the remote starter’s power directly to the vehicle’s battery with the appropriate fuse.
  7. If necessary, connect the remote starter’s fused 12V power wire directly to the T-Harness if it cannot be powered through Data-Link.
  8. After completing all the wiring connections, test the Vehicle Remote Starter to ensure it functions as intended.

Note: These usage instructions provide a general overview. For detailed step-by-step instructions, please refer to the user manual provided with the product.

Vehicle functions supported in this diagramFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (1)

FIRMWARE VERSION VERSION LOGICIELLE

71.[52] MINIMUM
To add the firmware version and the options, use the FLASH LINK UPDATER or FLASH LINK MOBILE tool, sold separately FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (2)

  • Program bypass option
    • UNIT OPTION
      • A5
        • ON OUI
          AUX.1 Par défaut with OEM alarm
        • OFF NON
          AUX.1 without OEM alarm sans alarme d’origine
      • C1
        • OEM Remote status (Lock/Unlock) monitoring
  • IF THE VEHICLE IS NOT EQUIPPED WITH FUNCTIONAL HOOD PIN
    • A11
      • OFF NON
        • Hood trigger (Output Status).

MANDATORY INSTALLFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (4)

HOOD STATUS : THE HOOD PIN SWITCH MUST BE INSTALLED IF THE VEHICLE CAN BE REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF

Notice: the installation of safety elements are mandatory. The hood pin is an essential security element and must be installed
THIS MODULE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN. A WRONG CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE

DESCRIPTIONFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (17)FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (5)

T-HARNESS: 12V BATTERY

  • ATTENTION THE T-HARNESS CURRENT IS LIMITED AT 10 AMP MAXIMUM.
  • If the parking lights (+) require more than 10Amp. connect the remote-starter’s power directly to the vehicles battery with the appropriate fuse.
  • Some remote starters can not be powered through Data-Link. In these cases connect the remote starter’s fused 12V power wire directly to the T-Harness

WIRING CONNECTIONFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (6) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (7)

INSTALLATION WIRINGFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (8) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (9) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (10) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (11)

KEY BYPASS PROGRAMMING PROCEDURE FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (12) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (13) FORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (14)

The module is now programmed.
Use the remote of the remote starter or security system to test all of the supported features to ensure proper programming

REMOTE STARTER FUNCTIONALITYFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (15)

Module labelFORTIN-94851-2012-Ford-Explorer-Regular-Key-Remote-Starters-and-Alarm-Systems-FIG- (16)

Notice: Updated Firmware and Installation Guides Updated firmware and installation guides are posted on our web site on a regular basis. We recommend that you update this module to the latest fi rmware and download the latest installation guide(s) prior to the installation of this product

WARNING
The information on this sheet is provided on an (as is) basis with no representation or warranty of accuracy whatsoever. It is the sole responsibility of the installer to check and verify any circuit before connecting to it. Only a computer safe logic probe or digital multimeter should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or responsibility whatsoever pertaining to the accuracy or currency of the information supplied. The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way. Neither the manufacturer or distributor of this module is responsible of damages of any kind indirectly or directly caused by this module, except for the replacement of this module in case of manufacturing defects. This module must be installed by qualifi ed technician. The information supplied is a guide only. This instruction guide may change without notice. Visit www.fortinbypass.com to get the latest version

TECH SUPPORT
Tél: 514-255-HELP (4357) 1-877-336-7797
www.fortinbypass.com

Documents / Resources

FORTIN 94851 2012 Ford Explorer Regular Key Remote Starters and Alarm Systems [pdf] Installation Guide
94851 2012 Ford Explorer Regular Key Remote Starters and Alarm Systems, 94851, 2012 Ford Explorer Regular Key Remote Starters and Alarm Systems, Ford Explorer Regular Key Remote Starters and Alarm Systems, Key Remote Starters and Alarm Systems, Alarm Systems

References

Leave a comment

Your email address will not be published. Required fields are marked *