MOXA ITB-5105 Modbus TCP Gateway Controller- logo

Gateway Controller
User’s Guide
Model: ITB-5105

Introduction

This document describes the Gateway Controller (Model ITB-5105) overview and how to use Z-Wave™ functionality.

Feature Overview

The current product is a home gateway device. IoT devices such as sensors are connected and can be controlled with this device. This device supports various interfaces for the functionalities of Wireless LAN, Bluetooth®, Z-Wave™. The device can collect sensing data from various Z-Wave™ sensor devices, and uploading of the data to a cloud server by wired LAN communication is available.

The Gateway Controller has the following general features:

  • LAN Ports
  • Wireless LAN client
  • Z-Wave™ communication
  • Bluetooth® communication

※ The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc

Names of Product Device Parts

The front and back view of the product device and parts names are as follows.

MOXA ITB-5105 Modbus TCP Gateway Controller- Names of Product

No  Part Name
1 System Status Lamp
2 Inclusion/Exclusion Button (Mode Button)
3 Micro USB Port
4 USB Port
5 LAN Port
6 DC-IN Jack

LED Indication Information

System status LED/Lamp Indicator:

LED Indicator Device Status
White Turn on. Device is booting up.
Blue Turn on. Device is connected to the cloud and is operating normally.
Green Turn on. Device is trying to connect to the cloud
Green Blinking. Z-Wave Inclusion/Exclusion mode.
Red Blinking. Firmware update is in progress.

Installation

Installation of the Gateway Controller is only a one step process:
1- Connect an AC adapter to the gateway and plug it into an AC outlet. The gateway has no power switch.
It will begin operating as soon as it is plugged into the AC adapter/outlet.
The gateway needs to be connected to the internet via a LAN port.

Z-Wave™ Overview

General Information
Device Type
Gateway
Role Type
Central Static Controller (CSC)
Command Class

Support
COMMAND_CLASS_APPLICATION_STATUS
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_CRC_16_ENCAP
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Control
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BASIC
COMMAND_CLASS_CRC_16_ENCAP
COMMAND_CLASS_MULTI_CHANNEL _V4
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DOOR_LOCK_V4
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_METER_V5
COMMAND_CLASS_NODE_NAMING
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_SENSOR_MULTILEVEL_V11

Securely S2 Supported Command Class
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_VERSION_V2

Interoperability
This product can be operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers.All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Security Enabled Z-Wave Plus™ Product
The gateway is a security enabled Z-Wave Plus™ product.

Basic Command Class Handling
The gateway will ignore Basic Commands received from other devices in the Z-Wave™ network.

Support for Association Command Class
Group id: 1 – Lifeline
Maximum number of devices that can be added to the group: 5
All devices are associated with the group.

Android Controller Application “Gateway Controller”

Gateway Select Screen
When an available device is detected that can be used, the icon of the gateway is displayed.
If nothing is displayed, please confirm that the network is correctly set.

MOXA ITB-5105 Modbus TCP Gateway Controller- Gateway Select Screen

Device Viewer

MOXA ITB-5105 Modbus TCP Gateway Controller- Device Viewer

MOXA ITB-5105 Modbus TCP Gateway Controller- Device ViewMOXA ITB-5105 Modbus TCP Gateway Controller- Gateway Select Scr

MOXA ITB-5105 Modbus TCP Gateway Controller- Gateway Select

MOXA ITB-5105 Modbus TCP Gateway Controller-Battery

MOXA ITB-5105 Modbus TCP Gateway Controller- button

MOXA ITB-5105 Modbus TCP Gateway Controller- meter

Inclusion (Add)

MOXA ITB-5105 Modbus TCP Gateway Controller- Inclusion

To add a device to the Z-Wave™ network, press the “Inclusion” button in the Android Controller Application. This will put the gateway into Inclusion Mode. Then a gateway  operation dialog will appear in the Android Controller Application. The gateway operation dialog will be displayed during the Inclusion Mode. To stop the Inclusion Mode,  press the “Abort” button in the gateway operation dialog, or wait for one minute and the Inclusion Mode will automatically stop. When the Inclusion Mode has stopped, the gateway operation dialog will automatically disappear.

MOXA ITB-5105 Modbus TCP Gateway Controller- Gateway S

Exclusion (Remove)

MOXA ITB-5105 Modbus TCP Gateway Controller- Device Vi

To remove a device from the Z-Wave™ network, press the “Exclusion” button in the Android Controller Application. This will put the gateway into Exclusion Mode. A gateway operation dialog will appear in the Android Controller Application. The gateway operation dialog will be displayed during the Exclusion Mode. To abort the Exclusion, press the “Abort ” butt on in the gateway operation dialog, or wait for one minute and the Exclusion Mode will automatically stop. When the Exclusion Mode has stopped, the gateway operation dialog will automatically disappear.

Lock/Unlock Operation

MOXA ITB-5105 Modbus TCP Gateway Controller- Device lViewMOXA ITB-5105 Modbus TCP Gateway Controller- Deviyh

Send Command

MOXA ITB-5105 Modbus TCP Gateway Controller- Send CommandMOXA ITB-5105 Modbus TCP Gateway Controller- DSend Command

Settings

MOXA ITB-5105 Modbus TCP Gateway Controller-SettingsMOXA ITB-5105 Modbus TCP Gateway Controller- Settings

Node Remove
To remove a failing node from the Z-Wave™ network, press “Node Remove” in the Settings dialog, and tap the Node ID to be removed in the Node Remove dialog.

MOXA ITB-5105 Modbus TCP Gateway Controller- bNode Remove

Node Replace
To re plac e a failing Node with another equivalent device, press “Replace” in the Settings dialog, and tap the Node ID to be replaced in the Node Replace dialog. The Gateway Operation dialog will appear.
MOXA ITB-5105 Modbus TCP GatewayNode Replace

Reset (Factory Default Reset)
Press “RESET” in the Factory Default Reset dialog. This will reset the Z-Wave™ chip, and the gateway will show “DEVICE RESET LOCALLY NOTIFICATION” after the restart. If this controller is the primary controller for your network, resetting it will result in the nodes in your network becoming orphaned, and it will be necessary after the reset to exclude and re-include all of the nodes in the network. If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable.MOXA ITB-5105 Modbus TCP GatReset

SmartStart
This product supports SmartStart integration and can be included in the network by scanning the QR code or entering the PIN.MOXA ITB-5105 Modbus TCP Gateway Controller- SmartStart

As the camera starts, hold it over the QR code.
Register the DSK when you correctly hold the camera over a QR code on the product label.MOXA ITB-5105 Modbus TCP Gateway Controller- As the camera

Z-Wave S2(QR-Code)

MOXA ITB-5105 Modbus TCP Gateway Controller- Z-Wave

Replication (Copy)

In the event that the gateway is already the controller of the Z-Wave™ network, put the gateway into Inclusion Mode, and put another controller into the Learn Mode. The Replication will begin and network information will be sent to another controller. In the event that the gateway is integrated into an existing Z-Wave™ network, put the gateway into Learn Mode, and put the existing controller into Inclusion Mode. The Replication will begin and network information will be received from the existing controller.

Documents / Resources

MOXA ITB-5105 Modbus TCP Gateway Controller [pdf] User Guide
ITB-5105, Modbus TCP Gateway Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *