Perlick logoQUALITY & INNOVATION THAT INSPIRES
Signature Series Stainless Steel 24
Built in Left Hinge Beer Dispenser

Right Cleaning Instructions

To ensure brewery-fresh flavor, it is recommended that the beer system be cleaned after every barrel or every two weeks to eliminate bacteria, yeast and beer stone build-up in the system.
Below, you’ll find instructions on how to properly and thoroughly clean your beer dispenser.

Supplies needed:

  • Cleaning Kit – Includes cleaning pump jar (A), coupling washer (B), 4 oz. BLC line cleaning chemical (C), check ball lifter (D), cleaning brush (E) and spanner wrench (F) (Kit Part No. 63797, shown right)
  • Buckets
  • Water (warm and cold)

Perlick Signature Series Stainless Steel 24 Built in Left Hinge Beer Dispenser

Perlick Signature Series Stainless Steel 24 Built in Left Hinge Beer Dispenser - Symbol CAUTION: The chemicals used to clean beer lines are hazardous. Please follow all recommended safety instructions on the chemical’s container.

  1. Turn off the CO2, either at the CO2 cylinder or at the air distributor.
  2. Remove tapping device (keg coupler) from the barrel.
  3. If tapping device contains a check ball, insert check ball lifter into the bottom of the coupler (Perlick Low Profile Coupler does not contain a check ball).
  4. Place tapping device into a small bucket.
  5. Using a spanner wrench, remove the beer faucet from the dispensing head.
  6. Fill cleaning pump with warm water.
  7. Attach cleaning pump jar connector with washer to where faucet was removed from dispensing head.
  8. Pump the warm water through the system to remove all remaining beer from the system. Empty tapping device bucket and rinse out. Place tapping device back into the bucket.
  9. Fill cleaning pump jar with water and cleaning chemical per the recommendations on the cleaning chemical container.
  10. Pump cleaning solution into system, leaving about a 1/2 the solution in the cleaning pump jar.
  11. Let stand 15 minutes, then pump remaining solution through the system
  12. Using a cleaning brush, clean the exterior surfaces of the tapping device and rinse with clean fresh water
  13. Rinse out cleaning pump jar with fresh water
  14. Fill cleaning pump jar with clean warm water and pump entire jar through the system
  15. Repeat step 13 using clean cold water
  16. During the 15 minutes that the solution is in the system, mix a small container with water and cleaning chemical per the instructions on the clenaing chemical container and disassemble the faucet per faucet manufacturers recommendations and let soak in solution
  17. Using cleaning brush, clean the components of the faucet
  18. Rinse all components of the faucet in clean fresh water. Check all seals on the faucet for wear and replace if necessary
  19. Reassemble faucet
  20. Remove cleaning pump jar from dispensing tower connection and reinstall faucet using spanner wrench to tighten properly
  21. Turn on CO2 and tap new keg

Perlick logo

Documents / Resources

Perlick Signature Series Stainless Steel 24 Built in Left Hinge Beer Dispenser [pdf] Instructions
Signature Series Stainless Steel 24 Built in Left Hinge Beer Dispenser, Signature Series, Stainless Steel 24 Built in Left Hinge Beer Dispenser, Hinge Beer Dispenser, Beer Dispenser, Dispenser

References

Leave a comment

Your email address will not be published. Required fields are marked *