Cecilware-logo

Cecilware C-2003G-IT Century 2000-IT Coffee Brewing Equipment

Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-product-image

CENTURY 2000-IT, COFFEE BREWING EQUIPMENT

MODELS

  • C-2003G-IT
  • C-2003RG-IT
  • C-2003LG-IT

Cecilware sells value… Worldwide

  • 43 -05 20th Avenue, Long Island City, NY 11105
  • TEL: 718-932-1414
  • FAX: 718-932-7860

SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT
Volts 120 120 120
Watts 1,800 1,800 1,800
Amps 15 15 15
Wall Outlet (Receptacle) 5-15R 5-15R 5-15R

All Brew Centers are single phase with 2 wires plus a ground with cord and plug, except Eport 220V, 1 PH, 50 cycles (UROPEAN).

MECHANICAL SPECIFICATIONS

MODEL NO. C-2003G-IT C-2003RG-IT C-2003LG-IT
Tank Capacity (US gal.)
Cups/Brew Cycle 12 12 12
Cups/Hour 120 120 120
Height (includes 2 ½” legs) 31 31 31
Width 8 16 16
Depth (+2”for ¼”water connection) 17 ¼ 17 ¼ 17 ¼
Ship Weight lbs. 40 50 50

START-UP PROCEDURE

  1. PLUG THE POWER CORD INTO A PROPER RECEPTACLE.
  2. ACTIVATE THE POWER SWITCH ON (Toggle Up), located in the lower left corner in back of Brewer.
  3. PUSH THE POWER BUTTON (RED) ON THE TOUCHPAD ON THE FRONT PANEL.
    The power switch controls all power including the Heater Elements in the tank and the Warmers. The Brewer will automatically start filling the tank, then it will start to heat up the water in the tank, until it reaches the proper preset temperature (200°F) (About 20 minutes). The LCD window will display a series of messages:Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-12
  4. PLACE PAPER FILTER AND COFFEE IN THE FUNNEL, AND INSERT FUNNEL IN THE BREWER.
  5. PUSH THE BREW BUTTON. YOU NEED NOT WAIT FOR THESE MESSAGES TO COME UP FIRST. After the brew button is pressed, when the “READY TO BREW” message comes on, the Brewer automatically begins brewing coffee. The LEDs will light up and stay on during the brewing cycle.
    NOTE: THE BREWER CAN BE PROGRAMMED TO START ITSELF UP AT ANY DESIRED TIME AND SHUT ITSELF OFF AT ANY DESIRED TIME, PROVIDED THAT THE MAIN POWER SWITCH IN THE BACK OF THE BREWER IS KEEPT ON (Toggle Up).

RECOMMENDED COFFEE AMOUNT FOR BREWING

2.5 oz. for one (1) decanter, ½ US gal. (12 cups)

FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER

  1. 100% Solid State Control for improved reliability.
  2. Modular design and reduced component count for ease of service.
  3. Optional Low Water Temperature Lockout to prevent dispensing at water temperatures below an adjustable threshold.
  4. Redundant system interlocks for uncompromising user safety.
  5. Large two line display for viewing system status on digital display and modifying parameters.
  6. Individual brew cycle counters and totalizers for product marketing information and inventory control.
  7. Advanced system diagnostics that continuously monitor the status of valves, sensors, and heaters to ensure proper operation and aid in identifying potential problems.
  8. Protection from heater burnout due to low water level in the reservoir tank.
  9. Stable water temperature regulation with adjustment to one-degree Fahrenheit.
  10. Units of measure displayed in either English or Metric.
  11. Digital adjustment of brewing size in ounce.
  12. Audible alarms: a) When brew cycle is ready b) Warmers Warning “time to brew new batch of coffee”.
  13. Optional power saving “sleep mode” for extended periods of inactivity (self turn off and on, as programmed).

INSTALLATION AND OPERATING INSTRUCTIONS

Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer.

UNPACKING AND INSPECTION
Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer.

ASSEMBLY AND SET-UP
The Brewer is shipped complete with:

DESCRIPTION C-2003G-IT C-2003RG-IT C-2003LG-IT
Decanters 3 3 3
Funnels with sample Filter pack 1 1 1

WATER HOOK UP
The National Sanitation Foundation (NSF) requires the following for NSF approved installation:

  1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the Brewer can be moved for cleaning underneath.
  2. An approved flow-back prevention device such as a double check valve to be installed between Brewer and water supply.

WATER CONNECTION

  • The Brewer comes equipped with a ¼ inch flare water inlet fitting located in the back. Use a ¼ inch copper tubing to connect the Brewer to a cold water supply. Water pressure should be: 20 PSI min. to 90 PSI max. An external shut-off valve and a water filtering system with a charcoal filter are highly recommended.
  • Turn water supply on and check for leaks at the water inlet connections, tighten flare fitting if necessary.

ELECTRICAL CONNECTIONS
For standard connections, Plug Power cord into a proper electrical outlet 15A.

PROGRAMMING INSTRUCTIONS

Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (1)

The following is a Functional Description of the Single Station Brewer:

Modes of Operation – Overview

  • Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to perform some special self-testing functions and configure the system using the previously saved operating parameters.
  • Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control brewing.
  • Service Mode – This mode becomes active when the hidden keys under the Cecilware Logo (located on the upper-left-hand side of the keypad) and the first letter of the Model Name (located on the upper-right-hand side of the keypad) are simultaneously depressed for more than two seconds while in Normal Mode. The main function of this mode is to allow access (for qualified personnel) to all system parameters that can be modified.
  • Error Mode – This mode becomes active when the system detects a fatal error. The main function of this mode is to disable the unit and report the error to the operator.

MODES OF OPERATION – DESCRIPTIONS

Initialization Mode: The following screen signifies the presence of this mode: CECILWARE

&&&&& REV #.#

Description – This mode is active only during the first few seconds after “power-on”. The purpose of the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number (depicted by “#.#”).
Normal Mode: The following screen signifies the presence of Normal Mode: SSSSSS         DDD K SSSSSS  HH:MMP
  • Description – Normal Mode is active immediately after Initialization Mode. The left half of the screen displays the present System State (depicted by “S”). Refer to the subsequent State Descriptions in this section for more information on System States. The right half of the screen displays the present day of the week (depicted by “D”), the present time (depicted by “HH”:”MMP”), and the current KeyLock Status (depicted by “K”). The day of the week is identified using familiar three letter abbreviations.
  • The time is identified using hours and minutes along with a “AM/PM” indicator. If KeyLock is enabled the” KL” symbol will be present. Enabling KeyLock will prevent unauthorized users from operating the unit. Refer to the Service Mode Descriptions for more information on the KeyLock function.
Filling State FILLING  DDD K TANK  HH:MMP
Description – This screen is displayed during the initial filling of the water tank (first fill). Once the water in the reservoir tank has reached the appropriate fill level this screen is retired.
Heating State: HEATING      DDD K TTTF      HH:MMP
Description – This screen is displayed when the present water temperature is below the Lockout Temperature Set Point. The actual water temperature is displayed in the lower left-hand portion of the screen (depicted by “TTTF”). If the Brew Key is depressed while in the Heating State the system will advance to the Waiting State. If the Brew Key is depressed for more that three seconds the Waiting State is bypassed and the system will advance to the Brewing State.
Waiting State WAITING      DDD K TTTF      HH:MMP
  • Description – This screen is displayed when the operator presses the Brew Key while the system is in the Heating State. The actual water temperature is displayed in the lower left-hand portion of the screen (depicted by “TTTF”). The Brew Key LED will blink in this state. Once the water temperature reaches the Lockout Temperature Set Point the system will automatically advance to the Brewing State.
  • Pressing the Brew Key or the Cancel Key while in the Waiting State will cause the system to revert back to the Heating State.
Ready (to Brew) State READY          DDD K TO BREW  HH:MMP
  • Description – This screen is displayed when the system is ready to begin a Brew Cycle. Pressing the
  • Brew Key while in the Ready State will advance the system to the Brewing State (i.e. begin a Brew Cycle).
Brewing State BREWING     DDD K MM:SS      HH:MMP
  • Description – This screen is displayed when a Brew Cycle is in progress. The time remaining in the Brew Cycle is displayed in the lower left-hand corner of the screen (depicted as “MM:SS”). The Brew Key LED will blink in this state. The Main Warmer is automatically activated upon entry into this state. The Brewing parameters of Brew Size, Dilution, Pre-Infusion, Pulse Brew, and Drip Time are utilized in this state. Refer to the Service Mode Descriptions for more information on Brew parameters.
  • Pressing the Brew Key or the Cancel Key while in the Brewing State will abort the Brew Cycle and revert the system to the Ready State.
Brew Fill Constant Calibration State
Description – The Brew Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the [Down Arrow] Key and the Brew Key. The system will immediately energize the Dump Solenoid (and dispense hot water) for exactly 10 seconds. The required Brew Fill Constant can be verified by dividing the volume of hot water dispensed by 10 thus yielding the actual Brew Fill Constant in ounces per second.
Warmers
Description – The warmers are generally controlled manually via the Warmer Keys on the keypad. The only situation when this is not the case is during a Brewing Cycle. The Main Warmer is automatically turned ON when the system enters the Brewing State. Each Warmer has an optional timer, power level, audible alarm, and power reduction feature associated with it. The Warmer Timer is particularly useful to indicate when a brew has become stale. Refer to the Service Mode Descriptions for more information on Warmer options.
Real-Time-Clock
Description – The Real-Time-Clock (RTC) allows the system to automatically turn ON at a specified time (usually in the morning) and turn OFF at a specified time (usually at night). The RTC also has separate settings for weekdays and weekends. This feature eliminates the wait associated with heating up the reservoir tank every morning. Refer to the Service Mode Descriptions for more information on Real-Time-Clock parameters.

SERVICE MODE

Description – The main function of Service Mode is to give qualified personnel the ability to configure the system to meet the requirements of each installation.

General Conventions (unless otherwise indicated)

  1. To enter or exit Service Mode simultaneously depress both the hidden key under the Cecilware Logo (CW Key) and the hidden key under the first letter of the Model Name (MN Key) until the buzzer sounds (approximately two seconds).
  2. Depressing the MN Key will cause the menu to scroll up and depressing the CW Key will cause the menu to scroll down.
  3. Depressing the [Up Arrow] Key or [Down Arrow] Key individually will increase, decrease, or toggle the displayed parameter respectively.
  4. Simultaneously depressing both the [Up Arrow] Key and the [Down Arrow] Key is used to acknowledge a request for confirmation (i.e. ARE YOU SURE?).
  5. Modified parameters are saved upon scrolling to a different menu.
  6. The system will automatically exit Service Mode and enter Normal Mode if the keypad remains idle (i.e. no keys are pressed) for more then three minutes.
KEYLOCK KEYLOCK ON/OFF
Description – The KeyLock feature disables all keys on the keypad. This feature prevents unauthorized users from tampering with the controls. For user convenience a method has been provided to temporarily override KeyLock. While depressing the hidden Cecilware (CW) Key the KeyLock feature is disabled. This allows authorized users to easily start a Brew Cycle while preventing unauthorized users from doing the same. The presence of the “KL” symbol on the screen in Normal Mode indicates the status of KeyLock (see Normal Mode Descriptions).
DISPENSE TOTAL DISPENSE TOTAL ######## OZ
Description – The Dispense Total is the total volume of hot water automatically dispensed since the machine was assembled at the factory. This value cannot be changed or reset!
BREW CYCLES BREW CYCLES #####
Description – The Brew Cycles screen displays the value of the Brew Cycle Counter. The Brew Cycle Counter contains the total number of completed Brew Cycles since the counter was last reset. The Brew Cycle Counter can be reset (set to zero) by simultaneously depressing the [Up Arrow] Key and [Down Arrow] Key for approximately two seconds.
BREW SIZE BREW SIZE ###.# OZ
Description – The Brew Size is the required volume of hot water dispensed during each Brew Cycle.
BREW FILL CONSTANT BREW FILL CONST #.## OZ/SEC
Description – The Brew Fill Constant is the exact value of the rate at which hot water is dispensed from the Dump Solenoid Valve during each Brew Cycle. The accuracy of this value is crucial to the proper operation of this system. This value is directly related to the orifice size of the Dump Solenoid Valve. A simple method for calibrating the Dump Solenoid Valve has been provided in Normal Mode (see Brew Fill Constant Calibration section of Normal Mode Descriptions).
PRE-INFUSION – OPTIONAL PRE-INFUSION ON/OFF
Description – The Pre-Infusion feature gives the user the ability to “wet” the grinds for a period of time (Infusion Time) and then allow the grinds to “soak” for a period of time (Soak Time) before brewing.
INFUSION TIME – OPTIONAL INFUSION TIME ## SECONDS
Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into the grinds during the Pre-Infusion process.
SOAK TIME OPTIONAL SOAK TIME ## SECONDS
Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusion period and the beginning of brewing.
PULSE BREW – OPTIONAL PULSE BREW ON/OFF
Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing (pulsing) hot water.
PULSE ON TIME -OPTIONAL PULSE ON TIME ## SECONDS
Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot water during a Brew Cycle.
PULSE OFF TIME -OPTIONAL PULSE OFF TIME ## SECONDS
Description – The Pulse OFF Time is the amount of time that the system will wait between hot water dispenses during a Brew Cycle.
DRIP TIME DRIP TIME ### SECONDS
Description – The Drip Time is the amount of time that the system will wait after the completion of the hot water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining in the funnel to drain out.
WATER TEMPERATURE WATER TEMP ### °F
Description – The Water Temperature is the required (set point) temperature of the water in the reservoir tank.
TEMPERATURE SENSOR CALIBRATION TEMP SENSOR CAL ARE YOU SURE ?
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed temperature to match the reference thermometer. Depress one of the [Hidden] Keys when the calibration is complete. TEMP SENSOR CAL ### °F
LOCKOUT TEMPERATURE LOCKOUT TEMP ### °F
Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a Brew Cycle to begin unless the water is above the Lockout Temperature.
SLEEP TIMER SLEEP TIMER ON/OFF
Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.
WARMER POWER WARMER POWER ### %
Description – The Warmer Power feature allows the user to reduce the actual heating power of the warmers. The percentage displayed is percentage of maximum power.
WARMER TIMER WARMER TIMER ON/OFF
Description The Warmer Timer feature allows the user to set the maximum length of time a brew remains fresh while being warmed. Once the Warmer Timer has expired an alarm is generated. An alarm consists of a blinking warmer LED and (optionally) the audible alarm (buzzer) sounding. The Warmer Timer is reset (restarted) by cycling the warmer Off and On.
AUDIBLE ALARM AUDIBLE ALARM ON/OFF
Description – The Audible Alarm feature allows the user to enable/disable the buzzer from indicating that the Warmer Timer has expired.
WARMER TIME WARMER TIME ### MINUTES
Description – The Warmer Time is the length of time that a warmer can be continuously energized before an alarm is generated.
WARMER REDUCTION WARMER REDUCTION ON/OFF
Description – The Warmer Reduction feature allows the user to gradually reduce the actual heating power of the warmers. This reduction of power is taken over the Warmer Timer period.
REDUCTION PERCENTAGE REDUCTION PCT ### %
Description – The Reduction Percentage is the percentage of Warmer Power that is gradually reduced over the Warmer Time.
WEEKDAY TIMER WEEKDAY TIMER ON/OFF
Description – The Weekday Timer function allows the system to automatically turn ON at a specified time and turn OFF at a specified time every weekday (Monday – Friday).
WEEKDAY TIME ON WEEKDAY TIME ON ##:## #M
Description – The Weekday Time ON function allows the user to set the required weekday turn ON time.
WEEKDAY TIME OFF WEEKDAY TIME OFF ##:## #M
Description – The Weekday Time OFF function allows the user to set the required weekday turn OFF time.
WEEKEND TIMER WEEKEND TIMER ON/OFF
Description – The Weekend Timer function allows the system to automatically turn ON at a specified time and turn OFF at a specified time every weekend (Saturday – Sunday).
WEEKEND TIME ON WEEKEND TIME ON ##:## #M
Description – The Weekend Time ON function allows the user to set the required weekend turn ON time.
WEEKEND TIME OFF WEEKEND TIME OFF ##:## #M
Description – The Weekend Time OFF function allows the user to set the required weekend turn OFF time.
CLOCK SETUP CLOCK SETUP ON/OFF
Description – The Clock Setup function allows the user to adjust (set and calibrate) the systems Real- Time-Clock.
ADJUST SECONDS ADJUST SECONDS DAY HH:MM:##
Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock Seconds placeholder.
ADJUST MINUTES ADJUST MINUTES DAY HH:##:SS
Description – The Adjust Minutes function allows the user to adjust (set) the systems Real-Time-Clock Minutes placeholder.
ADJUST HOURS ADJUST HOURS DAY ##:MM:SS
Description – The Adjust Hours function allows the user to adjust (set) the systems Real-Time-Clock Hours placeholder.
ADJUST DAY ADJUST DAY ### HH:MM:SS
Description – The Adjust Day function allows the user to adjust (set) the systems Real-Time-Clock Day placeholder.
CLOCK CALIBRATION CONSTANT CLOCK CAL CONST ##
Description – The Clock Calibration Constant function allows the user to calibrate the systems Real- Time-Clock (RTC). Each unit corresponds to approximately five seconds per month. Thus, if the RTC is running five seconds slow per month then the Clock Calibration Constant needs to be increased by one. Conversely, if the RTC is running five seconds fast per month then the Clock Calibration Constant needs to be decreased by one.
UNITS UNITS ENGLISH/METRIC
Description – The Units function allows the user to select English (oz, °F) or Metric (mL,°C) units of measure.
DEFAULT VALUES DEFAULT VALUES ARE YOU SURE ?
Description – The Default Values function allows the user to set all system parameters back to their Factory Default Settings. This provides a known (reference) configuration for troubleshooting purposes. DEFAULT VALUES COMPLETED

ERROR MODE

Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” using the Power Key located on the membrane keypad to reset any reported error.
KEYPAD ! SYSTEM ERROR ! KEYPAD
  • Description – This screen is displayed and the unit is disabled when a key-press is detected during the initial application of power to the system. This test is not performed during a Power Key initiated “power-on” sequence.
  • Possible Causes – Membrane Keypad or someone depressing a key while applying power to the system
110/220VAC ON ! SYSTEM ERROR ! 110/220VAC ON
  • Description – This screen is displayed and the unit is disabled when line voltage is detected before the Safety Relay is energized.
  • Possible Causes – Wiring or Safety Relay
110/220VAC OFF ! SYSTEM ERROR ! 110/220VAC OFF
  • Description – This screen is displayed and the unit is disabled when line voltage is not detected after the Safety Relay is energized.
  • Possible Causes – Wiring, Fuse, High Temp Limit Switch, Control Board or Safety Relay
HIGH WATER TEMP ! SYSTEM ERROR ! HIGH WATER TEMP
  • Description – This screen is displayed and the unit is disabled when the present water temperature is sensed as being higher than 208 °F.
  • Possible Causes – Wiring, Power Triac, Control Board or Water Temperature Sensor.
OVER FLOW ! SYSTEM ERROR ! OVER FLOW
  • Description – This screen is displayed and the unit is disabled when the Over Flow Level Sensor is detecting the presence of water.
  • Possible Causes – Wiring, Fill Solenoid, Control Board or Level Sensor
NO FILL RESPONSE ! SYSTEM ERROR ! NO FILL RESPONSE
  • Description – This screen is displayed and the unit is disabled when the Fill Solenoid has been continuously energized (open & filling) for more than 15 minutes during the first fill or more than 30 seconds thereafter.
  • Possible Causes – Water Supply is turned off, Wiring, Control Board, Fill Solenoid or Level Sensor
NO TEMP RESPONSE ! SYSTEM ERROR ! NO TEMP RESPONSE
  • Description – This screen is displayed and the unit is disabled when the Water Heater has been continuously energized (heating) for more than 45 minutes.
  • Possible Causes – Wiring, Control Board, Water Temperature Sensor, Power Triac, or Water Heater
DUMP #1 CLOSED ! SYSTEM ERROR ! DUMP #1 CLOSED
Description – This screen is displayed and the unit is disabled when the system has been brewing (dispensing) for more than one minute and the Level Sensor has not sensed the absence of water. Possible Causes – Wiring, Control Board, or Dump Solenoid.
TEMP SENSOR ! SYSTEM ERROR ! TEMP SENSOR
  • Description – This screen is displayed and the system is shut down when the Water Temperature Sensor is detecting an invalid (below 32°F or above 220°F) water temperature.
  • Possible Causes – Wiring, Control Board or Tempera1t2ure Sensor.

C-2003G-IT FRONT OPEN VIEW

Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (2) Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (3)

TOP CABIN OPEN VIEW Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (4) Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (5)

PARTS IDENTIFICATION FOR C-2003G-IT, C-2003LG-IT, C-2003RG-IT
ITEM SPARE

PARTS

P/N QTY DESCRIPTION
1 * NG34A 1 TOUCH PAD LABEL: C-2003G-IT, C-2003LG-IT, C-2003RG-IT
2 * L616A 1 THERMISTER PROBE
3 * L615A P182A K624A

P301A

1

2

1

2

TRIAC 25 AMPS SCREW F/ TRIAC HEATSINK, F/TRIAC, COPPER WINGED NUT F/ HEATSINK
4 M483A 1 SILICONE HOSE ( .312”ID x 20”L) TANK DRAIN
5 R958A 1 FRONT COVER
6 * L069A 1 POWER SWITCH
7 * C396Q 1 FUSE HOLDER ASS’Y
8 C032A 1 POWER CORD 15 A
9 H328Q 1 FITTING & TUBING ASS’Y FOR WATER HOOKUP
10 M042A 1 FEET [SET OF 4]
11 * V001A 1 FUNNEL, BLACK
12 * CD257 1 WATER INLET VALVE
13 * M483A 1 SILICONE HOSE (.312”ID x 12”L) WATER INLET
14 RV33Q 1 TANK WELDMENT ASS’Y
15 * L573A 1 HI-LIMIT, SURFACE MOUNT 220 ˚F
16 * G356A 1 HEATER (1.5 KW 120V)
17 E105A

K668A

1

1

SPRAY HEAD [BUNN]

SPRAY HEAD ADAPTER

18 D042A 1 FAUCET, HOT WATER
19 * G095A 3 WARMER PLATE & ELEMENT ASS’Y
20 RV52A + RS33A

RV62A

1+2 CABINET TOP COVER C-2003G-IT

CABINET TOP COVER C-2003LG-IT & C-2003RG-IT

21 RV34Q 1 TANK TOP ASS’Y
22 P465A 1 SCREW, ¼-20 x 5/8
23 * K402Q 1 WATER LEVEL CONTROL PROBE
24 * L467A 1 DINSPENSE VALVE, SINGLE [CD251– ALTERNATIVE]
25 * M    A 1 SILICONE HOSE (.125”ID x 8”L) BREATHER HOSE
26 * L683A 1 TEE ASS’Y
27 * B203A 1 RELAY, 110V, 16VDC (POWER SAFETY)
28 * CH87A 1 TRANSFORMER
29 * L669A 1 CONTROL BOARD
30 H360Q

M197A

1

1

SPRAY HEAD FITTING ASS’Y WITH

RUBER WASHER

31 * M483A 1 SILICONE HOSE ( .312”ID x 7”L) DISPENSE VALVE
32 * M483A 1 SILICONE HOSE ( .312”ID x 11”L) HOT WATER FAUCET

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal

components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact

PROBLEM PROBABLE CAUSE REMEDY
1 No power to the machine.
  1. Loose wire connection.
  2. Inoperative Power Safety Relay
  3. Fuse
  1. Check wire connections to Relay. See Power Safety Relay Test.
  2. Replace Power Safety Relay, if inoperative.
  3. Replace defective fuse if open.
2. Machine keeps repeating cycle.
  1. Touch Pad defective.
  2. Inoperative Power Safety Relay.
  1. Replace Touch Pad.
  2. Replace Relay.
3. Water does not shut off. Water keeps running into funnel.
  1. Leaking Water Inlet Valve [Solenoid].
  2. Inoperative Switches on Touch Pad.
  3. Clogged Dispense Valve
  1. Clean/check fittings of Valve. Replace Valve if needed. See ”Water Inlet Valve Test”
  2. Check Touch Pad connections. Replace Touch Pad if needed.
  3. Clean Dispense Valve. Replace Dispense Valve if inoperative.
3. Water will not stop flowing into tank.
  1. Water Level Probe malfunction.
  2. Water Inlet Valve malfunction..
  1. Check Probe. Replace if necessary. See “Probe Test”
  2. Check Solenoid. Replace if necessary. See “Water Inlet Valve Test”
4. Water drips from brew funnel.
  1. Leaking Dispense Valve.
  2. Too much water in tank.
  3. Spray Head Fitting is clogged.
  4. Water Valve blocked by scales.
  1. Replace Water Dispense Valve.
  2. Dispense some water from tank.
  3. Clean Spray Head Fitting.
  4. Replace or clean Valve Seat.
5. No water is going into tank at all.
  1. Water Inlet Valve (Solenoid) malfunction.
  2. Water Level Probe malfunction.
  1. Check Water Inlet Valve. Replace if necessary. See “Water Inlet Valve Test”
  2. Check Probe. Replace if necessary. See “Probe Test”.
6. Water is not heating up in the water tank.
  1. Temperature setting is incorrect.
  2. Loose connection to Heating Element or Heater Safety Relay.
  3. Heater is burned out or defective.
  4. Inoperative Heater Safety Relay.
  1. Set Temperature at 200°F – See Programming Instructions.
  2. Make sure all wires are tight.
  3. Replace the Heater.
  4. Replace Heater Safety Relay, if inoperative. See Heater Safety Relay Test.
7. Cold coffee.
  1. Run out of hot water in tank.
  2. Temperature setting is incorrect.
  3. Loose electrical connection.
  4. Bad or burnt out Heating Element.
  1. Allow time for water in tank to heat after filling.
  2. Set temperature at 200°F. (See Programming Instructions)
  3. Check all electrical connections for contact.
  4. Replace Heater.
8. Coffee too strong.
  1. Water flow too low.
  2. Too much coffee in the brew funnel.
  1. Adjust water flow rate on Dispense Valve.
  2. Put the proper amount of coffee in funnel. See suggested amount.
9. Coffee too weak.
  1. Not enough coffee in the brew funnel.
  2. Water flow too high.
  3. Temp. too low.
  1. Add coffee.
  2. Adjust water flow rate on Dispense Valve.
  3. Adjust heater temperature. See programming instructions.

SPECIAL COMPONENTS TEST AND ADJUSTMENTS

  1. WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin)
    1. Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this test a few times. The problem may be in the Probe. If the water does not flow in when the cord is plugged into an electrical outlet, the Solenoid coil may be damaged, opened or the valve may have an obstruction preventing the water from flowing in.
    2. Clean or replace it.
    3. A Check Valve is installed to prevent backflow.
    4. To check proper function of Check Valve, disconnect water line from the Check Valve, check for dripping from the disconnected end of the Check Valve.
    5. If it leaks replace it.
    6. Water inlet Valve max. flow rate is 1.3 gal/min.
      Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (6)
  2. WATER LEVEL PROBE TEST (Located on tank top, inside top cabin)
    If there is a lack of water, you will get an error message on the LCD window.
    1. Check the probe as follows:
      Turn on the power from touchpad and water supply. Check inside the tank to make sure the water is not touching the Probe. Pull the wire and terminal out of the Probe rod. If water starts flowing into the tank, the Probe may be grounded, due to excessive liming. Check with Ohm meter. Clean or replace.
  3. POWER SAFETY RELAY TEST (Located inside top cabin)
    1. Turn power switch on from touchpad. Measure Voltage across Input to Coil, between terminals1& 2. Should read approx. 9V to 10V D.C.
    2. Measure Voltage across Input, between terminals “COM” to Ground. Should read 120V.
    3. Measure Voltage across Output, between terminals “NO” to Ground. Should read 120V.
      Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (7)
  4. HEATER SAFETY RELAY TEST (240V UNITS ONLY) (Located inside top cabin)
    1. Make sure power switch in back of unit is on (toggle up).
    2. Turn power switch on (energize) from touchpad. Measure Input Voltage across coil, between terminals 0 & 1. Should read 120V.
    3. Measure Output Voltage across Heater Element. Should read 220 V. If there is no
    4. Voltage across the Heating Element, measure Output Voltage between terminals 4 & 8.
    5. Turn power switch off from touchpad. The Voltage should be a constant 220V even when not energized. Turn power switch on) from touchpad. Measure Voltage across terminals 2 & 6. Should read 220V.
    6. If 120V was applied to relay coil and it does not energize, replace relay.Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (8)
  5. CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin)
    1. Drain The Water Tank To Just Below The Level Of The Dispense Valves.
    2. Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed.
    3. Replace The Valve Into The Tank And Refill tank.
    4. The SINGLE DISPENSE VALVE is factory adjusted to dispense 0.35 oz./sec. of water during the brew cycle (spray duration).

TO ADJUST WATER FLOW RATE:

  • Locate adjustment screw on valve (as show here).
  • Using an Allen Key or a flat screwdriver, rotate ¼ turn at a time, Clockwise (CW) to decrease water flow rate or Counter-Clockwise (CCW) to increase water flow rate. Check water flow output after each ¼ turn. Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (9)

CLEANING AND SANITIZING

SANITIZING:
All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first.

To prepare a sanitizing solution:

  • ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with a unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span.
  • Soak all parts for a minimum of 3 min. in the sanitizing solution.
  • Let all sanitized parts drain and dry naturally. DO NOT WIPE THEM DRY.
  • Before using the sanitized unit (or parts) with food stuffs, rinse all parts thoroughly with water.
  • Water pipe connecting and fixtures directly connected to a potable water supply shall be sized, installed, and maintained in accordance with Federal, Sate, and Local codes (section 7).

CLEANING:

  1. Empty contents from brew funnel, wash and let dry (use a mild dishwasher detergent).
  2. To wash machine surfaces, first turn power switch OFF, wipe down machine surfaces, then turn power switch ON.

Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (10) Cecilware-C-2003G-IT-Century-2000-IT-Coffee-Brewing-Equipment-01 (11)

Documents / Resources

Cecilware C-2003G-IT Century 2000-IT Coffee Brewing Equipment [pdf] Instruction Manual
C-2003G-IT Century 2000-IT Coffee Brewing Equipment, C-2003G-IT, Century 2000-IT Coffee Brewing Equipment, Coffee Brewing Equipment, Brewing Equipment, Equipment

References

Leave a comment

Your email address will not be published. Required fields are marked *