DELTA ATLO-KRMD-520 Code Lock 

DELTA ATLO-KRMD-520 Code Lock 

Description

The unit is single door multifunctional standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz MI fare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output , and a backlit keypad. These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.

Features

  • Waterproof, conforms to IP65/IP68
  • Strong Zinc Alloy Electroplated anti-vandal case
    Full programming from the keypad
  • 2000 users, supports Card, PIN, Card + PIN
  • Can be used as a stand alone keypad
  • Backlight keys
  • Wiegand 26 input for connection to external reader
  • Wiegand 26 output for connection to a controller
  • Adjustable Door Output time, Alarm time, Door Open time
  • Very low power consumption (30mA)
  • Fast operating speed, <20ms with 2000 users
  • Lock output current short circuit protection
  • Easy to install and programme
  • Built in buzzer
  • Red, Yellow and Green LEDS display the working status

Specification

Input Voltage AC/DC 12V
Idle Current <25mA
Lock output load <1A
Alarm output load <1A
Ring bell load <1A
Card reading distance 40mm Max
Card Frequency: 125KHz for EM and HID 13.56MHz for MI fare
Card transmission format 26-37 bit Wiegand
Keypad transmission format: 4bit,8bit and Virtual card number
Operating Temperature:-45°C~55° C
Operating Humidity: 0%~95%

Installation

  • Remove the back cover from the keypad using the supplied special screw driver
  • Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
  • Put the supplied rubber bungs to into the two holes
  • Fix the back cover firmly on the wall with 2 Self tapping screws
  • Thread the cable through the cable hole
    Attach the keypad to the back cover.
    Installation

Wiring

ZONE1 ZONE2
No. Marks Color Description Marks Color Description
1 BELL_A pink Doorbell button D0 green Wiegand output D0
2 BELL_B pink Doorbell button D1 white Wiegand output D1
3 ALARM+ red Alarm anode AC1 red AC1 (+12V)
4 AC2 black AC input GND black GND
5 OPEN2 yellow Exit button OPEN1(LED) yellow Exit button (for green LED)
6 D_IN2 brown Door contact D_IN1(BZ) brown Door contact(for buzzer)
7 ALARM2- gray Alarm 2 ALARM1- gray Alarm 1
8 NO2 Blue Relay 2 NO end NO1 Blue Relay 1 NO end
9 COM2 purple Relay2Com COM1 Purple Relay1 Com
10 NC2 orange Relay2 NC end NC1 Orange Relay1 NC end

Sound and Light Indication

Operation LED Color Buzzer
Standby Red flash
Press key Di
Read card Green Di-
Door 1 Open Green Di-
Door 2 Open Green Flash Di-
Operation Successful Green Di-
Operation Failed Di  Di Di
PIN Inputting Red
Card & PIN Reading Red
Multi Card Reading Red
Under Menu Red
Under Setting Orange
Manager Card Enter Orange Di Di
Manager Card Exit Red Flash Di-
Alarm Red Quick Flash Alarm

Quick Programming Guide

Administrator Setting

Stand by Master Code Menu Setting Remarks Functions
Red Flash Red Red Orange
* Master code# 00 New master code# Repeat new master code # (Note: Code length:6-8 digits) Factory default: 999999 Change the master code
01 Read Manager Add Card Default: Zone 1 Set Manager Add Card
02 Read Manager Delete Card Set Manager Delete Card
03 Read Anti-duress card (Zone 1) Set Zone1 Anti-duress card
04 Read Anti-duress card (Zone 2) Set Zone2 Anti-duress Card
05 Anti-duress PIN# (Zone 1) Set Zone1 Anti-duress PIN
06 Anti-duress PIN# (Zone 2) Set Zone2 Anti-duress PIN
07 0000# Delete All Users
51 Master open Lock 1
52 Master open Lock 2

User setting for Zone 1

Stand by Master Code Menu Setting Remarks Functions
Red Flash Red Red Orange
* Master code

#

11 Read card Users can be added continuously without exiting programming mode To add card users
User ID number# read card
Card number#
ID number # card number#
User ID number # PIN# To add PIN users
12 Read card Users can be deleted continuously without exiting programming mode To delete users
User ID number#
Card number#
13 0# Default 2 Entry by Card
1# Entry by card + PIN
2# Entry by either Card or PIN
14 0-99# Default 5 Set door relay time
15 0# Default 0 Relay Setting-Pulse mode
1# Relay Setting-Toggle mode
16 1-10# Default 1 To set open door by multi cards
17 User ID number#, card number#, card quantity# To add a series cards users

System Setting

Stand by Master Code Menu Setting Remarks Functions
Red Flash Red red orange
* Master code

#

30 0-15# Default 0 To set facility code
31 0# When device reset to factory default  ,the setting is still valid Wiegand reader
1# Standalone for single door (Factory default setting)
2# Standalone for two doors
3# With external reader for two doors
4# Two units interlocked for two doors
5# Anti-pass back for single door
6# Anti-pass back for two door
1# Safe mode 1
2# Safe mode 2

User optional setting

 Stand by Master Code  Menu  Setting  Remarks  Functions
Red Flash Red red orange
* Master code # 41 0# Buzzer will be be in silence except enter the programming mode
1# Default 1 Buzzer will sound when press the key
42 0# Disable keypad backlight
1# Enable keypad backlight
2# Default 2 Automatic mode, Normally it is off(sleeping mode) but wake up with human approach
43 0# LED Light Disable when stand-by status
1# Default 1 LED flash when stand-by status

Instruction:

  1. Master code must be 6-8 digits, Anti-duress PIN must be 8 digits, user PIN is 4-6 digits, The 1st digit of user PIN and Anti duress PIN in Zone1 must be 1; The 1st digit of user PIN and Anti-duress PIN in Zone 2 must be 2.
  2. the user ID number is any number among 1-2000,Invalid 0 can be omitted; card number must be 8 or 10 digits, if the card number is less than 8 or 10 digits, input 0 before the card number.
  3. Door open time is 0-99 second,0=50mS
  4. when register one card user into the device, the device will automatically generate a PIN 1234 , this PIN cant open the door door.
  5. when an invalid master pin is pressed the device will go back to the standby status after 5 seconds, when a valid PIN is entered it will go back to standby status after 30 seconds.
  6. in operating the keypad, pressing # means to confirm the input digits ,In operation of a cycle adding or deleting cards, pressing # means to end the cycle operation and back the up operation; pressing * means to exit the operation.
  7. When add a series cards, this unit will make the ID number and card number initial value; after adding one user, then it will increase the ID number and card number automatically ,Until the specified number of card is added. the card number must be consecutive card quantity is between 1-2000.
  8. Working mode and keypad transmission format have been set before shipping, customer can change according to requirement, but when device reset to factory default, the setting is still valid.
  9. when users of Zone 1 is registered successfully, LED will turn green; when users of Zone 2 is registered successfully, LED will be green flash.

Administrator setting

Administrator setting on keypad

Press * Master code # factory default: 999999,

Change the master code

Press 00 new code # repeat new master code#
Note: Master Code length: 6~8 digits

Set Manager card

Set manager add card
Press 0 1 read manager add card
Set manager delete card
Press 0 2 read manager delete card
Note: when add the new manager card, the new one will automatically cover the old card, only one manager card for one device.

Set Anti-duress card

Set Anti-duress card for Zone 1
Press 03 read anti-duress card (Zone 1)
Set Anti-duress card for Zone 2
Press 04 read anti-duress card (Zone 2)
Note: when add the new anti-duress card, the new one will automatically cover the old card, only one anti-duress card for one device.

Set Anti-duress PIN

Set Anti-duress PIN for Zone 1
Press 05 8-digit duress PIN#(Zone 1)
Set Anti-duress card for Zone 2
Press 06 8-digit duress PIN#(Zone 2)

Note:

  1. the 1st digit must be 1 for Zone 1
  2. the 1st digit must be 2 for Zone 2
  3. when set the new anti-duress PIN, the new one will automatically cover the old anti-duress PIN, only one anti-duress PIN for one
    device.

Delete all users

Press 07 0000 #
Note: both zone 1 and zone 2 will be deleted. This is a dangerous option, so use with care.

Set administer open lock

Set administer open Lock 1
Press 51
Set administer open Lock 2
Press 52

Users setting for Zone 1

  1. read card to add user
    Press 11 read card # read card#
  2. use ID Number and read card to add user
    Press 11 ID number # read cardID number # read card #
  3. use card number
    Press 11 card number #card number##
    Note:
    1. Card number must be 8 or 10 digits, if the card number is less than 8 or 10 digits, input 0 before the card number
    2. Automatically increases, the user ID will be generated by the machine automatically, the range is 1 ~ 2000, and
      automatically search from 1 to 2000
  4. Use ID number and card number to add user
    Press 11 ID number # 8-digits card number #ID number# 8-digits card number# #
    Note:
    1. ID number is 1~4 digits, the range is 1~2000, 1,01,001,0001, all these mean ID number 1.
    2. add card user will generate one “1234 “PIN, this PIN cant open door, only for user modify PIN
  5. use ID number and PIN to add user
    Press 11 ID number# PIN #ID number# PIN##
    Note: this fit PIN user, pin is irrelevant with card, the PIN is any 4-6 digits,1st digits must be 1 for Zone 1 with the exception of 1234 which is reserved.

Delete user

  1. read card to delete user
    Press 12 read card read card#
  2. use ID number to delete user
    Press 12 ID number # ID number ##
  3. use card number to delete user
    Press 12 card number # card number ##
  4. delete all users
    Press 07 0000 #
    Note: both zone 1 and zone 2 will be deleted.

Set opening door mode:

  1. Entry is by card only
    Press 13 0 #
  2. Entry is by card and PIN together
    Press 13 1 #
  3. Entry is by card or PIN (factory default)
    Press 13 2 #

set door relay time

Press 14 0~99 #
Note: 0~99 is to set the door delay time 0-99 seconds, factory default is 5 seconds

Set Relay mode

Relay setting -pulse mode
Press 15 0 #
Every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time. (Factory default setting)
Relay setting-Toggle mode
Press 15 1 #
Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again

Set opening door by multi cards

Press 16 card quantity #
Note: the door will be opened only after reading all the valid multi cards up to the card quantity setting. It is only for card entry mode (Factory default setting :1)

Add a series consecutive cards users

Press 17 ID number # card number # card quantity #
Note: the card number must be consecutive card quantity is between 1~20000; card number is 10 digits or 8 digits

User setting for Zone 2
The method is the same with Zone 1, corresponding menu should be 21,22,23,24,25,26,27

system setting

  1. To set facility code
    Press 30 0~15 #
    Note: code should be 0~15, factory default setting :0
  2. Winging Reader
    Press 31 0 #
  3. standalone for single door(Factory default setting)
    Press 31 1 #
  4. Standalone for two doors
    Press 31 2 #
  5. With external reader for two doors
    Press 31 3 #
  6. Two units interlocked for two doors
    Press 31 4 #
  7. Anti-pass back for Single door
    Press 31 5 #
  8. Anti-pass back for two doors
    Press 31 6 #

To set wigging format

Press 32 26 34 37 #
Note: factory default setting :26

setting keypad transmission format

Press 33 0~2 #
Note: keypad transmission format is 0 1 2, factory default is 0; when device reset to factory default, the setting is still valid.

Setting alarm time

Press 34 1~3 #
Note:

  1. factory default is 1 minute
  2. when device reset to factory default, the setting is still valid.

setting safe mode

  1. normal mode (factory default)
    Press 35 0 #
  2. dead mode
    Press 35 1 #
    If read invalid card or input wrong PIN 10 times in 10 minutes, system will be dead for 10 mins
  3. alarm mode
    Press 35 2 #
    if read invalid card or input wrong PIN 10 times in 10 minutes, external alarm and built-in buzzer will work.

user optional setting

user optional setting

  1. setting keypad tone OFF or ON
    Press 41 0 #
    The device will be in silence except enter the programming mode
    Press 41 1 #
    The device will give the voice when press the keys (Factory default setting)
  2. setting keypad backlight
    Disable keypad backlight
    Press 42 0 #
    Enable keypad backlight
    Press 42 1 #
    Automatic mode (factory default setting)
    Press 42 2 #
    Normally it is off(sleeping mode) but wake up with human approach
  3. setting LED light (stand-by status)
    Disable LED light
    Press 43 0 #
    Flash LED light (factory default setting)
    Press 43 1 #

Manager card operation

add user for Zone1

Read Manager Add Card, read user cards continuously, read Manager Add card again.

delete user for Zone 1

Read Manager Delete Card, read user cards continuously, read Manager Delete card again.

User Operation

  1. Entry by card mode, Set multi cards to open door when card quantity is 1
    Read user card, lock will be unlocked
  2. Entry by card mode, Set multi cards to open door when card quantity is 2-10
    Read these cards one by one, present each card in 5 seconds, lock will be unlocked
  3. Entry by card and PIN
    Present card, then press PIN(4 to 6 digits ), #, lock will be unlocked
  4. Entry by card or PIN mode
    Present card, lock will be unlocked Or Press PIN(4 to 6 digits ), #, lock will be unlocked
  5. Relay mode
    Relay setting -pulse mode
    every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time.
    Relay setting-Toggle mode
    Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again
  6. Modify user PIN (no need enter programming mode)
    *, read user card, press old PIN, #, new PIN # new PIN # Or *, press ID number # old PIN# new PIN # new PIN #
    Notice: user who don’t have user card must get ID number and origin PIN from Admin, Zone 1 users PIN must start with 1, Zone 2 users PIN must start with 2.

Alarm function

  1. Anti-tamper alarm if the device is disassembled illegally, the buzzer and the external alarm will operate.
  2. Door contact alarm When connect with door contact, if the door is opened illegally, the buzzer and the external alarm will operate.
  3. The Anti-duress alarm When read zone 1 anti-duress card/input 8-digit anti duress PIN or zone 2 anti-duress card/input 8-digit anti duress PIN, then press #, The corresponding lock will open, at the same time, the external alarm will operate, but the device buzzer will not operate.
  4. remove alarm read valid user card, manager card or input master code, then alarm will be removed. If no any operation, alarm will be removed automatically after 1 min.

Multi working mode

There are 7 working mode with this device.1.Wiegand Reader, 2.Standalone for single door, 3.standalone for two doors,4.with external reader for two doors 5.two units interlocked for two doors,6.Anti-passback for single door,7.Anti-passback for two door. The factory default is Standalone for single door (we can change the default model according to customer order). User can modify the working mode, when the device reset to factory default, the setting is still valid.

Wiegand Reader mode

In this mode, the access control works as reader, connected with the common access controller, it has following function. Modify master pin Set facility code Set the card transmission format Set the keypad transmission format Set optional setting Anti-Tamper alarm.

When LED level is low, indicator light(LED) will turn into green, after 30 seconds or LED level rising, LED will back to normal.
When BZ level is low, the buzzer will beep, after 30 seconds or BZ level rising, the buzzer will back to normal. When it used as the reader, both card number and keypad transmits in Winging format, the output data are shown by the low level of DO&D1 wire:
D0: low level means 0,green wire
D1: Low level means 1,white wire

The Pulse width of low level is 100uS,bit period is 1.6mS.
The digits of card number can be set to 26-37 bit, should be matched with the controller.(Factory default is 26Bit).
Keypad transmission can be set in the following 3 modes(modes can be set by user).

Model 0: Virtual card number
The reader will transmit the PIN data when it receives the last key(#) press after PIN code
Format: Decimal card number with 10 digits, Facility code(1st~4th digit)+PIN Code(5th-10th digit)
Facility code is any digits between 0~15,PIN code is 4~6 digits
Example: facility code :15
PIN code: 9999
Press 9999 #, then output format will be: 0015009999
PIN code: 999999
Press 999999#,then output format will be 0015999999

Model 1: 4 Bit

The output data is provided in following format after every key is pressed:

key Output in hex Output in Binary
0 0 0000
1 1 0001
2 2 0010
3 3 0011
4 4 0100
5 5 0101
6 6 0110
7 7 0111
8 8 1000
9 9 1001
* A 1010
# B 1011

Model 2: 8 Bit

The output data is transmitted in following format after every key is pressed:

key Output in hex Output in Binary
0 0 11110000
1 1 11100001
2 2 11010010
3 3 11000011
4 4 10110100
5 5 10100101
6 6 10010110
7 7 10000111
8 8 01111000
9 9 01101001
* A 01011010
# B 01001011

Standalone for single door

In this mode, the device supports connecting external card reader for exiting door.
The users of Zone 1 or external can open the door by valid card or PIN.

Standalone for two doors

In this mode, users are for controlling two doors. Read valid card or input PIN of Zone 1 on this unit, door 1 will be opened; reading valid card or input PIN of Zone 2 on this unit, door 2 will be opened.
Remark: the common card for Zone 1 and Zone 2 can only open door 1.

With external reader for two doors

In this mode, this unit is for entering door 1,and external reader is for entering door 2.
Read valid card or input of Zone 1 on the machine, door 1 will open; read valid card or input PIN of Zone 2 on external reader, door 2 will open.
Remark: the common card for Zone 1 and Zone 2 can open door 1 on this unit, and open door 2 on external reader.

Two units interlocked for two doors

The interlock function is mainly used in banks ,prisons, and other places where a higher level security is required.
When and only door 2 closed, read valid card / input PIN on this machine, door 1 will open; when and only door 1 closed, read valid card/input PIN on external reader, door 2 will open.
Remark: The valid card /PIN is only for users of Zone 1,users of zone 2 are invalid.

Anti-pass  back for Single door

In this mode, this unit install outside is for entering door, external reader inside for exiting door, the users can only enter door when read valid card on the machine, and exit from the inside external reader. If without the entering record from the machine, the users can not exit from the inside reader, also the Users can’t enter in twice without the first exit record.
Remark: this is only for card users of Zone 1,PIN users of Zone 1 an all users of Zone 1 are invalid.

Anti-pass back for two doors

In this mode, this unit on door 1 is anti-pass back master unit, and external reader on door 2 aa the anti-pass back auxiliary unit. then they build up a two doors anti-pass back system, which is normally used for parking lot. The users can only enter door 1 when read valid card on this unit, and exit from door 2 when read valid card on external reader. If without the entering record from door 1, the users can not exit from the door 2, also the users can’t enter in twice without the first exit record.
Remark, this is only for card users of Zone 1,PIN users of Zone 1 and all users of Zone 2 are invalid.

diagram for 7 working mode

  1. Wiegand Reader mode
  2. Standalone for single door
  3. Standalone for two doors
  4. With external reader for two doors
  5. Two units interlocked for two doors
  6. Anti-pass back for Single door
  7. Anti-pass back for two doors
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode
    Diagram For 7 Working Mode

Instance Operations

  1. Modify master code as 201200
    press * 999999 # 0 0 201100 # 201100 # .
  2. Set Anti-duress PIN of Zone 1 as 12012000
    press * 201100 # 0 5 12012000 # .
  3. add last 8 digit card number as 00967865 and 86998736 user of Zone 1
    Press * 201100 # 1 1 00967865 # 86998736 # .
  4. add first 10 digit card number as 0098786500 and 8699873600 user of Zone2
    Press 201* 100 # 2 1 0098786500 # 8699873600 # .
  5. add ID user 006, PIN 201200, Zone 2 user
    press * 201100 # 2 1 6 # 201200 # .
  6. set open mode of Zone 1 as card + PIN
    press * 201100 # 1 3 1 # .
  7. rapid increase consecutive numbers 1000 cards (start with 00987865 ID is 005)
    press * 201100 # 1 7 05 # 00987865 # 1000 # .
  8. set working mode as reader mode
    press * 201100 # 3 1 0 # .
  9. set card output format as WG34
    press * 201100 # 3 2 34 # .
  10. set master open lock 1
    press * 201100 # 5 1 .

Simple Troubleshooting

Code Fault Fault Cause Solutions
1 Close Read range Quality of card Use original card
2 Problem in PIN setting
  1. PIN is not standard
  2. Set Password at reader mode
  1. first number of PIN should be 1 or 2,match with Area number
  2. PIN shouldn’t be 1234
  3. PIN is 4 to 6 digits
  4. don’t set PIN at reader mode
3 PIN can’t open door
  1. use PIN 1234
  2. entry mode setting
  1. 1234 is original PIN, can’t open the door, should be modified as other PIN
  2. set open mode as entry by card or PIN.
4 Alarms at normal condition While installation, light leak under bottom While installation, device should closed to the wall
5
6 No responds after card reading Units are not in ready mode Press * key, light flash, units back to ready mode
7 Keypad light is not bright Mode of keypad light setting is wrong
  1. set keypad light as shine or auto
  2. under auto mode, light shine after press keypad, delay 30 seconds
8 Can’t enter master mode Forget master code Reset to Factory Default, master code will be 999999,only installer data is restored, user data will not be affected

To Reset to Factory Default

a. Disconnect power from the unit.
b. Press and hold # key whilst powering the unit back up.
c. On hearing two “Di” release # key, system is now back factory settings.
Please note only installer data is restored, user data will not be affected.

Packing List

Name Model/size Quantity Remarks
Keypad CC1/CC2 1
User manual CC1/CC2 1
Self tapping screws Φ4mm×27 mm 2 Used in fixing
Rubber plug Φ6mm×30 mm 2 Used in fixing
Star screw driver Φ20mm×60mm 1 Special for Keypad
two-electrode valve 1N4007 1

Customer Support

Manufactured in China for:
DELTA-OPTI Monika Matysiak, 60-713 Poznan, 10 Graniczna St., Poland
www.shopdelta.eu

Documents / Resources

DELTA ATLO-KRMD-520 Code Lock [pdf] User Manual
ATLO-KRMD-520, ATLO-KRMD-510, ATLO-KRMD-520 Code Lock, Code Lock, Lock

References

Leave a comment

Your email address will not be published. Required fields are marked *