EuropeanHome 2000 Filio focus 2000 Central Version Instruction Manual
EuropeanHome 2000 Filio focus 2000 Central Version

Introduction

Please read this entire manual before you install and use your focus fireplace. Failure to follow instruction may result in property damage, bodily injury or even death. When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log listed to ANSI Z21.60 standard having an input rate of 65,000 Btu or less.

KEEP THIS MANUAL HANDY FOR EASY REFERRAL.

All WARNING and CAUTION statements will appear in bold font and upper case letters: THEY SHOULD BE STRICTLY OBSERVED.

Thank you for choosing focus fireplaces.

Appliance designation: central windowed filiofocus 2000

Manufacturer:
Focus – Atelier Dominique Imbert
Le fort – 34380 Viols le fort – France

Specifications

DO NOT INSTALL IN A MOBILE HOME. NOT FOR EXTERIOR INSTALLATION!
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION  DUCT WORK!
NOT TO INSTALL WITH MASONRY CHIMNEY SYSTEM. 

  • The authority having jurisdiction (such as municipal building department, fire department, fire prevention bureau, etc.) Should be consulted before installation to determine the need to obtain a permit.
  • Using make-shift compromises during installation can cause damage . Such installation is not covered under focus limited warranty.
  • When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
CHARACTERISTICS
  • Hearth 45-11/16-inch (1.16 m) diameter; Weight: 176 lbs (80 kg)
  • Hood weight: 190 lbs (86 kg)
  • Flue diameter: 10-3/4-inch (273 mm) ; length custommade
  • Flue weight: 18 lbs per foot (27 kg per meter)
  • Standard anchor plate weight: 55 lbs (approx. 25 kg)
  • 1/8-inch (3 mm) thick steel
  • High heat resistant matte paint
  • Guaranteed efficiency with a minimum flue lenght ( interior and exterior) of 10 feet (3m)
    Dimension
ROOF OUTLET REQUIREMENT

Safety Instruction

CHIMNEY REQUIREMENT

Do not connect this unit to a chimney flue serving another appliance !

Filiofocus 2000 central version requirement: the floor to top of chimney length must be 19 feet minimum (22 feet for an installation less than 3 miles from the ocean or if a 30° elbow is necessary). Elbows should not be more inclined than 30° (USA) or 45° (Canada) from vertical and with maximum number of 2. Maximum inside + outside height : 30 feet.

Windowed filiofocus can be connected to a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys, Factory-built, Residential Type and Building Heating Appliance, UL 103/ULC S629. For example, a class A insulated stainless steel flue chimney system with an 10-inch minimum inside diameter.

CAUTION

THE SUPPORT OF THE ANCHOR PLATE (ROOF STRUCTURE, SLAB, ETC…) MUST BE SIZED IN CONGRUENCE WITH THE FIREPLACE STATIC AND DYNAMIC CHARGES. THE SIZE CALCULATION FOR THE SUPPORT IS NOT THE RESPONSIBILITY OF FOCUS OR ITS AFFILIATES. IT IS YOUR RESPONSIBILITY TO CONSULT WITH AN ENGINEER OR ARCHITECT FOR YOUR PROJECT.

CONNECTORS

Connectors are all non-insulated chimney parts including focus flue, focus 10” universal adaptor and the chimney manufacturer finishing collar with adapter.
To avoid heat traps the chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling.
Passage through an attic, roof frame floor, or ceiling must be done using an insulated chimney respecting all chimney manufacturer clearances.
For Canada the installation should conform to CAN/CSA-B365.

CAUTION

PASSAGE THROUGH A WALL OR PARTITION OF COMBUSTIBLE CONSTRUCTION IS NOT AN APPROPRIATE INSTALLATION FOR THIS FOCUS FIRE.

FRESH AIR INTAKE

To balance room air pressure with outdoors air pressure, focus recommends a fresh air intake in the room (ideally emerging under the fire bowl). Fresh air intake shall only take combustion air from outdoors. We recommend deflect-O A0684 semi rigid aluminium duct. The appliance is supplied with a fresh air control.

Minimum fresh air intake size:
Instruction

IMPORTANT

this fresh air intake is compulsory when operating venting appliances such as kitchen hoods, permanent air extractors or any appliances creating an air depression in the habitation. A lack of air intake may alarm smoke detectors. Duct maximum length :30 feet (9 meters).

CLEARANCES TO COMBUSTIBLES

A. CLEARANCES TO FLOOR AND CEILING
Clearances to Combustibles

CAUTION
The floor protection remains identical with or without optional steel base.

B. CLEARANCE TO WALLS

CAUTION
THE DISTANCE TO A COMBUSTIBLE WALL MUST BE MAINTAINED AT 34 INCHES FROM THE GLASSES. PROPERTY DAMAGE OR DEATH CAN OCCUR IF THIS DISTANCE IS NOT MAINTAINED. DRYWALL PRODUCTS LINED WITH PAPER SUCH AS SHEETROCK ARE COMBUSTIBLE. CLEARANCES AS INDICATED FURTHER APPLY.
Clearance to Walls

IMPORTANT

Manufacturer specifications:

  • When placed close to a non-combustible wall leave a minimum of 4 inches (100mm, from fire bowl which Ø is 46 inches – 1160mm) for proper ventilation. To avoid premature aging of your painted walls, only use mineral or acrylic paints. With other paints, above clearances apply.
  • Focus recommends the integration of the fire bowl in a 3 inches floor recess with 31-1/2” diameter.
  • Fire clearance to glass (from glasses) : 3 feet.
  • Fire clearance to vinyl windows: refer to window technical specifications.

Clearances may only be reduced by means approved by the regulatory authority.

Installation

INCLUDED PARTS, MATERIALS AND REQUIRED TOOLS FOR INSTALLATION

  • Appliance and designated parts are the fire bowl, grate, suspended hood, black steel flue pipe, anchor plate, 4 curved pyroceramic glass screens, focus kit ( protective glove, mounting gloves, can of touch-up paint), and insulating washers.
  • Required tools : drill, M8 allen key, level, screw drivers, M12 key, scaffolding, refractory compound.
  • 2 persons minimum are required for installation.
OPTIONS
  • Custom ceiling cover disc (steel disc) + cover-disc screw kit
  • Custom anchor steel plate (inclined…)
  • Focus steel flue extension
  • Custom roof outlet in stainless or lacquered steel with insulation and cap
  • Fire bowl installation options : set above floor level, or raised on a custom base

A.STAINLESS STEEL CHIMNEY SYSTEM ANCHOR PLATE DETAIL
Assembly Details

Hearth extensions must be installed only as illustrated.

B. FOCUS FLUE ATTACHMENT TO STAINLESS STEEL CHIMNEY SYSTEM PLATE
Assembly Details

C. THE ORDER TO TIGHTENING THE PLATE SCREWS (TO SECURE PROGRESSIVELY)
Assembly Details

Installation

GOOD TO KNOW

The hood and the fire bowl may not be perfectly and geometrically centered and aligned due to hood balance position. We strongly recommend to:

  • First install the hood, then find the right position of the fire bowl by installing the pivoting glasses : the best position is when the glass panels are sliding smoothly throughout the entire diameter of the track.
  • For ease of glass panels installation, the distance between the bottom of the hood and the finished surface that the fire bowl will sit must be 26-3/16’’ (665 mm).
  • The stationary glasses should be installed opposite one another
ASSEMBLY DETAILS FOR INSULATED CHIMNEY

Assembly Details
Assembly Details

Operating instructions

CAUTION

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

STORAGE / USE OF FLAMMABLE LIQUIDS

Never use chemicals or fluids, gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or « freshen up » a fire in this heater. Keep all such liquids well away from the heater while it is in use.

FIRE-DOGS

The fire-dogs item is located inside the fireplace. It must not be removed except for cleaning, once all cinders have thoroughly cooled. Fire must only be built on the fire-dogs.
Assembly Details

ASHES

DISPOSAL OF ASHES
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be immediately placed outdoors on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

FUEL

CAUTION
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. DO NOT STORE THE FUEL WITHIN THE SPACE HEATER INSTALLATION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR REFUELING AND ASH REMOVAL.

Only burn dry, natural, untreated well-seasoned wood. Wood moisture content should not be more than 20%. We recommend using 2 year dry stored wood. For the best efficiency use a covered storage. Hazards may occur with some fuels (e.g., charcoal). Such fuels may generate dangerous gas like carbon monoxide.

WARNING
THE WINDOWED FILIPINOS HAS BEEN TESTED FOR USE WITH FOUR GLAZED SCREENS FULLY CLOSED. IF PANELS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE. TO REDUCE THE RISK OF FIRE INJURY, DO NOT INTEND TO REMOVE GLAZED SCREENS! 

BEFORE LIGHTING YOUR FIRST FIRE

For all designs it is necessary:

  • To remove the stickers from the glass screens (if any).
  • To clean off (with a damp sponge and/or a dry cloth) any dirt collected during transport or installation.
  • Actual scratches on painted designs can be retouched solely with the expressly provided focus paint. If this is necessary, ventilate the area thouroughly before lighting your fire to disperse any fumes generated in the spraying process.

The first fire should be a modest one ; do not use packing material or pallet wood for fuel.
The paint finish we use, oven baked at 250°C for 30 minutes, is thermo-plastic. Because of the very gradual polymerisation of the components, the unit may give off a light smoke the first few times the fire is lit. The painted surfaces nearest the fire may, while hot, acquire a certain viscosity, or slight stickiness perceptible to the touch. We advise therefore:

  • Not to be alarmed at possible smoking or residual odors. This is normal on the first fires and will rapidely subside.
  • Not to touch, rub or try to clean the fireplace while it is still hot.

To avoid thermal shocks, we strongly advise against throwing buckets of water on a very vigorous fire to try to put it out.

BUILDING, STARTING AND MAINTAINING THE FIRE

CAUTION
DO NOT LIGHT OR FUEL A FIRE USING CARDBOARD OR PLASTIC OR ANY UNSTABLE OR VOLATILE FUEL SOURCE OR WITH FIRE BRICKS REMOVED, AS THIS WILL PRODUCE OVER-FIRING OR HOUSE FIRE. DAMAGE CAUSED FROM NON-OBSERVANCE OF THIS CAUTION IS NOT COVERED UNDER FOCUS LIMITED WARRANTY. 

Do not overload your focus fireplace to avoid over-firing.
Build the fire without elevating it, directly on the fire-dogs, not too close to the glasses. For starting the fire, we recommend using a small amount of fire starter with enough kindling (small logs or mill ends) to establish a primary fire. Fresh air intake must be fully open (push the handle in direction of the large side of the triangle, see hereunder illustration):
Operating instructions

After a few minutes, and making sure the primary fire is well started, add larger wood (between 3 and 7 pieces, depending on their size), directly on top, making sure not to smother the fire. Leave some spaces between the logs for air intake. Adapt the air intake position in order to avoid spillage of smoke.
To maintain or refuel your fire, add when needed (see note), a few larger logs.

NOTE :For the same weight of fuel, 10 logs will burn more intensely (and faster) than 3 logs, but you will get the same heat power at the end. The log size you buy will determine the heating and refueling time.

PROTECTIVE GLOVE

The use of the focus special protective glove supplied with our models is required upon handling the cold handle, glass panels, fresh air controls, fire-dogs, etc.

DAMPER OPERATION AND USE

Use of supplied cold handle tool or protective glove is recommended to operate the damper. Do not touch the damper handle without protection when a fire is operating.
The filiofocus 2000 central damper has four positions. The damper is in the same direction as the handle: when the handle is vertical, the damper is fully open. Handle can rotate at 30°, 60° and 90° (horizontal : closed). In closed position the damper obturates by 75% the flue section. To modify the damper position, first pull the handle, then rotate and push again the handle in order to lock on a preset position.

Maintenance

TAKING OUT THE ASHES

CAUTION
BE SURE THE FIRE IS OUT AND THE FIREPLACE BODY COLD BEFORE REMOVING ASHES!

To remove ashes we recommend to remove the fire-dogs and use a brush and a shovel. Dispose of ashes in an appropriate ash container (not supplied). After cleaning, be sure to secure the fireplace properly !

CAUTION
DO NOT LIGHT A FIRE WITH FIREDOGS REMOVED, AS THIS WILL PRODUCE OVER FIRING OR HOUSE FIRE. DAMAGE CAUSED FROM NON-OBSERVANCE OF THIS CAUTION IS NOT COVERED UNDER FOCUS LIMITED WARRANTY. 

INSPECTION, MAINTENANCE AND CLEANING OF THE CHIMNEY

CAUTION
CHEMICAL SWEEP NOT PERMITTED: ONLY MECHANICAL SWEEP ALLOWED!

A. REFERING TO FOCUS STEEL FLUE

It must absolutly be swept with a nylon brush. Never use metal brushes! Damage caused from non observance of this caution is not covered under the focus limited warranty

B. REFERING TO CHIMNEY PIPE

Creosote formation and need for removal:
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote.
The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote  buildup has occurred.
If a significant layer of creosote has accumulated (3mm or more) it should be removed to reduce the risk of a chimney fire.
In that case, call a professional chimney sweeper or buy a brush at your local focus retailer and clean the chimney this way:
Remove rain cap, use appropriately sized brush and sweep the entire system to remove all debris or refer to chimney manufacturer recommendations.
Communicate with the authorities (municipal, regional or provincial fire protection agency) to obtain all instructions concerning the measures to be taken when or before there is a risk of chimney fire.
Keep firing and de-ashing doors closed and maintain all seals in good condition.

SURFACES

CAUTION
DO NOT SCRUB!

The outer surfaces can be wiped with a soft, dry rag (making sure the metal is cool).
For continued use of the touch-up paint can, following its initial usage, invert the can (spray head down) and spray into a balled up newspaper until the can sprays clear. Clean the spray can bottom with a dry rag and store out of the reach of children.

DIRECTIONS AND REASONS FOR CLEANING GLASS

Cracked or broken glass should be replaced. Do not clean the glass when hot. Glass doors should not be struck or banged.

The outer surfaces can be wiped with a soft, dry rag and a standard glass cleaner product (making sure the glass is cool).
The inner surfaces can be cleaned with a special insert glass product.

REPLACEMENT PARTS

Do not use substitute materials.

4 Glass Panels
Glass Panels

Cold handle
Cold handle

Touch-up can
Touch-up can

Chenets
Chenets

2 Stationary pyroceramic sides:
Thickness 5/32’’ (4 mm)
Height : 23-5/8’’ – 600 mm
Radius : 12-7/8’’ – 327 mm
Dbeveloped length : 19-11/16’’ – 500 mm
2 pyroceramic glass door:
Thickness 5/32’’ (4 mm)
Height : 23-5/8’’ – 600 mm
Radius : 13-3/8’’ – 340 mm
Developed length : 23-5/8’’ – 600 mm

For ordering replacement parts, please contact the focus North American exclusive importer:

30 Log Bridge Road Building 300 – Suite 303 Middleton, MA 01949
T: 781-324-8383
www.europeanhome.com

Warranty

All of our Focus models are guaranteed against any defect in design, construction, or manufacture, and guaranteed to function properly for 5 years from date of order. Our product guarantees are applicable only when our fireplaces have been installed with respect to all local building codes and with strict attention to the technical details outlined in our Plan Study as well as our installation, maintenance, and users manuals. Our guarantee excludes accidental damages such as those occuring during transport without written notification upon receipt, damages incurred during installation, and damages resulting from improper use.

Annex

HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE

All floor protection must be non-combustible (i.e., metals, brick, stone, mineral fiber boards, etc.). Any organic materials (i.e., plastics, wood paper products, etc.) are combustible and must not be used. The floor protection specified includes some form of thermal designation such as R-value (thermal resistance) or k-factor (thermal conductivity).

A. PROCEDURE

  1. Convert specification to R-value:
    1. R-value given – no conversion needed.
    2. k-factor is given with a required thickness (T) in inches:
      Convert specification
    3. K-factor is given with a required thickness (T) in inches
      Convert specification
    4. r-factor is given with a required thickness (T) in inches:
      Convert specification
  2. Determine the R-value of the proposed alternate floor protector.
    1. Use the formula in step (1) to convert values not expressed as “R”.
    2. For multiple layers, add R-values of each layer to determine overall R-value
  3. If the overall R-value of the system is greater than the R-value of the specified floor protector, the alternate is acceptable.
    EXAMPLE: The specified floor protector should be 3/4-inch thick material with a k-factor of 0.84. The proposed alternate is
  4. ” brick with an r-factor of 0.2 over 1/8” mineral board with a k-factor of 0.29.

Step (a): Use formula above to convert specification to R-value.
Convert specification

Step (b): Calculate R of proposed system.
Convert specification

1/8” mineral board of k = 0.29, therefore
Convert specification

Rtotal = Rbrick + Rmineral board = 0.8 + 0.431 = 1.231
Step (c): Compare proposed system Rtotal of 1.231 to specified R of 0.893. Since proposed system Rtotal is greater than required, the system is acceptable.

B. DEFINITIONS
Dimension

Annex

GAS ADAPTATION

Gas kit:

Burner
Burner

Burner cover
Burner cover

  1. Gas line location on the floor
    Burner cover
  2. Cut hole though the Filiofocus central
    Burner cover
  3. Follow the steps on page 13 of the European Home Gas Stones Natural Vent Manual. 6 1/2″ (167 mm)

European Home Logo

Documents / Resources

EuropeanHome 2000 Filio focus 2000 Central Version [pdf] Instruction Manual
2000, 1600, 2000 Filio focus 2000 Central Version, 2000, Filio focus 2000 Central Version, focus 2000 Central Version, Central Version, Version

References

Leave a comment