Taco-logo

Taco 2400-WB Wood Boiler Series Hi Capacity Circulator

Taco-2400-WB-Wood-Boiler-Series-Hi-Capacity-Circulator-product-image

Specifications

  • Product Name: 2400-WB Series Outdoor Wood Boiler Hi-Capacity Circulator
  • Model Number: 102-349
  • Effective Date: January 5, 2023
  • Application: Indoor use only

Product Usage Instructions

Location
Do not use the circulator in swimming pool or spa areas. Ensure the boiler enclosure is weather-tight if installed on the boiler.

Operating Specifications

  1. Disconnect and lock-out electrical supply to the pump.
  2. Close isolation valves on suction and discharge sides of the pump. Drain the system if valves are not installed.
  3. For installations above 5000 feet elevation, maintain a fill pressure of at least 20 psi to prevent pump cavitation.
  4. Use only o-ring gaskets provided to avoid leaks and warranty void.
  5. Allow access for periodic inspection of the mechanical seal and provide adequate drainage.

Installation Steps

  1. Using teflon tape or high-quality thread sealant, install Taco companion flanges on threaded pipe ends.
  2. Minimize pipe strain by using pipe hangers on suction and discharge lines.
  3. Position vertical and horizontal piping to match bolt-holes on the pump and companion flanges without forcing the lines into position.

Mounting Position
Do not support, suspend, or brace the pump motor to prevent early failure. The support provided by casing is sufficient for structural integrity.

Electrical Wiring

  1. Disconnect and lock-out all electrical power before proceeding with wiring.
  2. Attach an appropriate size connector to one of the two knock-out holes in the capacitor/conduit box.
  3. Connect the hot and neutral leads from the electrical supply to the respective black and white leads in the capacitor box using minimum 18 AWG wire.

Frequently Asked Questions (FAQ)

  • Q: Can this circulator be used outdoors?
    A: No, the circulator is designed for indoor use only.
  • Q: What should be done for installations above 5000 feet elevation?
    A: Maintain a fill pressure of at least 20 psi to prevent pump cavitation. Adjust expansion tank pressure accordingly.
  • Q: What type of gaskets should be used with this circulator?
    A: Only use o-ring gaskets provided to avoid leaks and warranty void.

Instruction Sheet

  • 2400-WB Series Outdoor Wood Boiler Hi-Capacity Circulator
  • SUPERSEDES: December 1, 2015
  • Plant ID# 001-3914
  • EFFECTIVE: January 5, 2023Taco-2400-WB-Wood-Boiler-Series-Hi-Capacity-Circulator-fig- (1)

INSTALLER: Please leave these instructions for owner’s use.

APPLICATION:

  • The Taco Wood Boiler Series Hi-Capacity circulators are designed specifically for use on unpressurized outdoor wood boiler applications. Features include a quiet running, close-coupled, thermally protected motor assembly with permanent split-capacitor and permanently lubricated bearings. A stainless steel shaft, silicon-carbide mechanical seal and non-ferrous impeller make the Wood Boiler Series Circulator an ideal choice for years of maintenance-free operation.
  • Note: Use Stainless Steel body circulators on open systems for the best corrosion protection.

CAUTION: Taco Wood Boiler circulators are designed for indoor use only. Be sure boiler enclosure is weather tight if installed on the boiler.

OPERATING SPECIFICATIONS

  • Maximum Working Pressure: 150 psi (1034 kPa)
  • Maximum Operating Temperature: 225ºF (107ºC)
  • Electrical Rating: 115V/60Hz/1Ph

REMOVAL OF EXISTING PUMP FROM SYSTEM PIPING:

  1. Disconnect and lock-out electrical supply to pump.
  2. Close isolation valves on suction and discharge sides of pump. If valves are not installed, the system may need to be drained.
    CAUTION: To prevent injury, allow system water to cool to 100ºF before removing old pump or draining system. Leave drain valve open until service/replacement is complete.
  3. Remove capacitor box cover and disconnect electrical supply lines to pump.
  4. Loosen flange bolts and shift pump body slightly to relieve any remaining system pressure.
  5. Remove flange nuts/bolts and pump from system.

INSTALLATION OF WOOD BOILER SERIES CIRCULATOR

Location:

  • WARNING: Do not use in swimming pool or spa areas; pump has not been investigated for this application.
  • WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main electrical unit.
  • CAUTION: When installing electrical connections, do not apply mechanical loads to the capacitor box; otherwise, retaining screws may be pulled out of the housing, making circulator unusable.
  • CAUTION:
    • The addition of petroleum based fluids or certain chemical additives to systems utilizing TACO equipment voids the warranty.
    • Use supply wires suitable for 90°C
  • CAUTION: Installations at higher elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation and flashing. Premature failure may result. Adjust expansion tank pressure to equal fill pressure. A larger size expansion tank may be required.
    • Install pump with sufficient room for future inspection, maintenance and service.
    • It is recommended that isolation valves be installed on the pump suction and discharge to simplify future service or replacement without draining the system.
    • Install pump at location with highest net positive suction head available (NPSHA), usually at the boiler supply outlet.
  • CAUTION: Do not use flat rubber gaskets. Only use o-ring gaskets provided or leaks may result. Warranty will be void.
  • CAUTION: This pump has a mechanical seal which may require service. Allow access for periodic inspection and leak detection. Provide adequate drainage to prevent property damage.
  1. Using teflon tape or high quality thread sealant, install Taco companion flanges on threaded pipe ends to ensure proper fit-up and leak protection.
    WOOD BOILER SERIES COMPANION FLANGE SETS
    CONNECTION 3

    ⁄4″

    1″ 1

    1 ⁄4″

    1

    1 ⁄2″

    Iron NPT 110-251F 110-252F 110-253F 110-254F
    Stainless Steel NPT 110-251SF 110-252SF 110-253SF 110-254SF
    Bronze SWT 110-523BSF 110-524BSF 110-525BSF 110-526BSF
    Shut-Off NPT SF-075T SF-100T SF-125T SF-150T
    Shut-Off SWT SF-075S SF-100S SF-125S SF-150S
  2. Minimize pipe strain on pump by using pipe hangers on the suction and discharge lines.
  3. Position vertical and horizontal piping so bolt-holes on pump and companion flanges match. Do not force the suction and discharge lines into position. This may create excess stress on the pump casing and flanges.

Mounting Position:

  • Always install pump with the motor shaft in the horizontal position and the capacitor/conduit box oriented on top of the motor housing, as shown in Fig. 1.
  • Standard pump body mounting position is with the flow in the up-discharge direction (body position #3). The pump body may be field-rotated in any direction to accommodate system piping and flow direction.
  • Be sure to align the arrow on the casing with desired flow direction.Taco-2400-WB-Wood-Boiler-Series-Hi-Capacity-Circulator-fig- (2)

CAUTION: Do not support, suspend or brace pump motor or early failure may result. Support provided by casing is sufficient for structural integrity of pump

Electrical Wiring:

  • All electrical wiring must be installed by a licensed electrician in accordance with local and national codes and regulations.
  • Electrical supply and grounding wires must be suitable for at least 90ºC (194ºF).
  • Wood Boiler Series circulators are thermally protected and do not require external overload protection.
  1. Be sure all electrical power to pump is disconnected and locked-out before proceeding with wiring.
  2. Loosen capacitor/conduit box screw and remove cover.
  3. Attach appropriate size connector to one of the two knock-out holes in the capacitor/conduit box.
  4. Using minimum 18 AWG wire, connect the hot and neutral leads from the electrical supply to the respective black and white leads in the capacitor box.
  5. Connect the ground wire to the green ground screw in the capacitor box.
  6. Replace capacitor/conduit box cover.
  7. Insert plastic plug provided in unused knock-out hole.

SYSTEM START-UP

CAUTION: Do not start the pump until the system has been completely filled and vented. Running the pump dry may damage the mechanical seal and void warranty.

  1. Prior to pump start-up, the system should be thoroughly cleaned, flushed and drained to prevent damage to seal surfaces.
    CAUTION: The majority of mechanical seal failures are due to poor media (fluid) quality in the system. To maximize seal life, media quality must be maintained in the system, and TDS (Total Dissolved Solids)/TSS (Total Suspended Solids) should not exceed 500ppm with standard Carbon/Silicon-Carbide seals. The use of inhibitor based glycols is acceptable, but additional inhibitors should not be added. Always follow the glycol manufacturer’s specification for system preparation and water quality. Treatment with silicates should not be used. Failure to maintain media quality will void the standard Taco warranty.
  2. Open isolation valves and re-fill system with clean water. Check for any leaks.
  3. Vent all air from system at an air vent located at the high point in the system.
  4. Start circulator to check for proper operation.

PERIODIC INSPECTION, MAINTENANCE

Taco Wood Boiler Series Hi-Capacity circulators are designed to provide years of trouble-free service. However, periodic inspection and routine maintenance is recommended for all hydronic systems and mechanical equipment. If any evidence of leakage or damage is present, take preventive steps to repair or replace the circulator immediately.

REPLACING THE MECHANICAL SEAL: Refer to Fig. 2 on back page.

  1. Follow steps 1 thru 5 in section “Removal of existing pump from system piping”.
  2. Loosen the four body bolts that attach the motor housing to the casing. While supporting the motor, remove the four bolts and carefully remove the motor and impeller assembly from the casing.
    CAUTION: Do not allow screwdriver to make contact with motor windings or insulation. Permanent damage to motor may result.
  3. To remove the impeller, first insert a screwdriver into the motor ventilation slots to make contact with one of the rotor cooling fins. While holding the rotor in place with the screwdriver, turn the impeller clockwise to loosen and remove from shaft.
  4. Remove the seal assembly from the shaft.
    Note: 2400 models with “3P” suffix are provided with a 3- piece rotating seal.
  5. Remove the face plate from the motor housing. To remove face plate, gently pry it away from the housing.
  6. Remove the old seal seat and cup. Lubricate the new cup with soapy water and install new parts in the face plate recess. Replace the face plate to its original position. Carefully tap the face plate evenly into the recess in the motor housing.
  7. Clean the impeller shaft before installing the new seal.
  8. Lubricate the impeller shaft with soapy water. Do not
    CAUTION: Do not allow screwdriver to make contact with motor windings or insulation. Permanent damage to motor may result.
    install new seal on a dry impeller shaft or damage to seal may result.
  9. Slide the new carbon seal and spring assembly onto the shaft until it contacts the silicon-carbide seal seat.
  10. While holding the rotor in place as in Step 3, thread the impeller onto the shaft in a counter-clockwise direction until it stops. Check to make sure the pump will rotate. If the impeller will not spin freely, contact Taco Technical Support at 1-401-942-8000.
  11. Remove old body gasket, clean the recess in the pump casing and install the new body gasket provided.
  12. Attach the pump casing to the motor housing and secure with the four body bolts. Be sure flow arrow is pointing in proper direction. Tighten the four bolts evenly in a crisscross pattern to 65 in-lb of torque. There should be a small, even gap between the casing and the motor mounting bracket.
  13. Re-install circulator into system using new flange gaskets. Refer to section “Installation of Wood Boiler Series Circulator” for complete mounting and wiring instructions.

Taco-2400-WB-Wood-Boiler-Series-Hi-Capacity-Circulator-fig- (3)

Taco-2400-WB-Wood-Boiler-Series-Hi-Capacity-Circulator-fig- (4)

Model Replacement Impeller Kits Replacement Motor Kits – 115V Replacement Motor Kits – 230V
RP Part # RP Part # RP Part #
2400-10 2400-020 RP 2400-006 RP
2400-20 2400-021 RP 2400-006 RP 2400-010 RP
2400-30 2400-022 RP
2400-40 2400-023 RP
2400-45 2400-024 RP 2400-017 RP 2400-018 RP
2400-50 2400-025 RP 2400-007 RP 2400-019 RP
2400-60 2400-026 RP 2400-006 RP 2400-010 RP
2400-65 2400-027 RP 2400-017 RP 2400-018 RP
2400-70 2400-028 RP 2400-007 RP 2400-019 RP

LIMITED WARRANTY STATEMENT

  • Taco, Inc. will repair or replace without charge (at the company’s option) any Taco 2400 circulator or circulator part which is proven defective under normal use within three (3) years from the date of manufacture.
  • In order to obtain service under this warranty, it is the responsibility of the purchaser to promptly notify the local Taco stocking distributor or Taco in writing and promptly deliver the subject product or part, delivery prepaid, to the stocking distributor. For assistance on warranty returns, the purchaser may either contact the local Taco stocking distributor or
  • Taco. If the subject product or part contains no defect as covered in this warranty, the purchaser will be billed for parts and labor charges in effect at time of factory examination and repair.
  • Any Taco product or part not installed or operated in conformity with Taco instructions or which has been subject to misuse, misapplication, the addition of petroleum-based fluids or certain chemical additives to the systems, or other abuse, will not be covered by this warranty.
  • If in doubt as to whether a particular substance is suitable for use with a Taco product or part, or for any application restrictions, consult the applicable Taco instruction sheets or contact Taco at (401-942-8000).
  • Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part. Taco reserves the right to make changes in details of design, construction, or arrangement of materials of its products without notification.
  • TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES. ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY FOR THE DURATION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARAGRAPH ABOVE.
    THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR STATUTORY, OR ANY OTHER WARRANTY OBLIGATION ON THE PART OF TACO.
    TACO WILL NOT BE LIABLE FOR ANY SPE-CIAL, INCIDENTAL, INDIRECT OR CONSE-QUENTIAL DAMAGES RESULTING FROM THE USE OF ITS PRODUCTS OR ANY INCIDENTAL COSTS OF REMOVING OR REPLACING DEFECTIVE PRODUCTS.
  • This warranty gives the purchaser specific rights, and the purchaser may have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts or on the exclusion of incidental or consequential damages, so these limitations or exclusions may not apply to you.

Taco, Inc., 1160 Cranston Street, Cranston, RI 02920
Tel: (401) 942-8000 Taco (Canada), Ltd., 8450 Lawson Road, Suite #3, Milton, Ontario L9T 0J8 |
Tel: (905) 564-9422 Visit our web site: www.TacoComfort.com | Printed in USA | ©2023 Taco, Inc.

Documents / Resources

Taco 2400-WB Wood Boiler Series Hi Capacity Circulator [pdf] Instruction Manual
2400-WB Wood Boiler Series Hi Capacity Circulator, 2400-WB, Wood Boiler Series Hi Capacity Circulator, Series Hi Capacity Circulator, Capacity Circulator, Circulator

References

Leave a comment

Your email address will not be published. Required fields are marked *