General Care and Safety Guide

Thank you for choosing this Goldair product. This Goldair appliance has been designed and manufactured to high standards of engineering and with proper use and care, as described in this leaflet, will give you years of useful service. Please read these instructions carefully and keep them for future reference.

  1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  2. Children should be supervised to ensure that they do not play with the appliance.
  3. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  4. Ensure that the fan is switched off from the supply mains before removing the guard.
  5. Use only the voltage specified on the rating plate of the appliance.
  6. Keep all objects at least 1 Metre from the front, sides, and rear of the appliance
  7. This appliance is intended for household use only and not for commercial or industrial use.
  8. Use this appliance only as described in this manual. Any other use is not recommended by the manufacturer and may cause fire, electric shock or injury.
  9. The common cause of overheating is deposits of dust or fluff in the appliance. Ensure these deposits are removed regularly by unplugging the appliance and vacuum cleaning the air vents and grills.
  10. Always unplug appliances when not in use.
  11. When the appliance has been unpacked, check it for transport damage and ensure all parts have been delivered. If parts are missing or the appliance has been damaged, contact the Goldair Customer Services Team.
  12. If your appliance does not work or is not working properly, contact the place of purchase. Repairing work on the appliance by unqualified persons can cause serious risk to the user.
  13. Ensure hands are dry before handling the plug or the main unit.
  14. Carry out regular checks of the supply cord to ensure no damage is evident.
  15. Ensure that the cord is fully extended (not coiled) while in use.
  16. Avoid contact with the moving parts. Keep hands, hair, and clothing, away from the blade of the fan during operation to reduce the risk of injury to a person and/or damage to the unit.
  17. Switch off and use the handles provided when moving.
  18. It is recommended that this fan is plugged directly into the wall socket.
  19. A correctly specified, an undamaged extension cord may be used with this fan provided it is used in a safe manner.
  20. Never place appliances close to the radiant heat source.
  21. Never operate in areas where petrol, paint, or other flammable liquids are used or stored.
  22. Never use the appliance to dry clothes.
  23. Never insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock, fire or damage to the appliance.
  24. Never use abrasive cleaning products on this appliance. Clean with a damp cloth (not wet) and rinsed in hot soapy water only. Always remove the plug from the mains supply before cleaning.
  25. Never connect the appliance to the mains supply until completely assembled and adjusted.
  26. Never remove the plug from the power socket until the appliance has been switched off.
  27. Never remove the plug from the power socket by pulling the cord – always grip the plug.
  28. Never twist the kink or wrap the cord around the appliance, as this may cause the insulation to weaken and split. Always ensure that all cord has been removed from any cord storage area and is unrolled before use.
  29. Never use this appliance in the immediate surroundings of a bath, a shower, or a swimming pool or other liquids. The appliance must not be immersed in any liquids.
  30. Due to the risk of injury, never use this appliance for any purpose other than its intended use. This appliance is intended for use in households and similar applications such as staff kitchen areas in shops, offices, and other working environments; farm houses, by clients in hotels, motels, bed and breakfast type environments, and other residential type environments
  31. Never use this appliance outdoors.
  32. Never operate the appliance with a damaged cord or plug, after it malfunctions, or if it has been damaged in any manner. Has the appliance been checked and repaired by a qualified electrician if repair is necessary?
  33. Never place the unit in wardrobes or other enclosed spaces as this may cause fire hazards.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-1

Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-2The appliance is filled with flammable gas R290.
Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-3Before using the appliance, read the manual.
Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-4Before installing the appliance, read the installation manual.
Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-5For any repairs required, contact the nearest authorized Service Centre and strictly follow the manufacturer’s instructions only.

WARNING: Appliance shall be installed, operated, and stored in a room with a floor area larger than 10m2. Do not use any means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources.
(example: open flames, an operating gas appliance, or an operating electric heater).
Do not pierce or burn. Be aware that refrigerants do not have any odor.

ComponentsGoldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-6 Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-7 Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-8

Installation

NOTE: The air-conditioner should be installed on a flat surface with at least 300mm clearance all around, including from the top of the unit as it is important that the air outlet is not blocked. Power supply must be nearby.

WARNING: THIS APPLIANCE MUST BE INSTALLED, OPERATED AND STORED IN A ROOM WITH A FLOOR AREA LARGER THAN 10m2

Do not install and use the appliance in the bathroom or other humid environments. Install the heat pipe assembly (as shown in Figure 1).
Screw the heat pipe assembly (exhaust fitting end) into the exhaust port on the rear panel (counterclockwise). Install the window sealing plate assembly
Half-open the window, and mount the window sealing plate assembly to the window (as shown in Figure 2 and Figure 3); the assembly can be placed in the horizontal and vertical direction. Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly. You may require a glazier to cut a hole in your window pane to fit the exhaust hose fixing clip.

Important Notice

The length of the exhaust hose shall be 280~1,500mm, and this length is based on the specifications of the air conditioner. Do not use extension tubes or replace it with other different hoses, or this may cause a malfunction. Exhaust must be unobstructed; otherwise, it may cause overheating.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-10

Control Panel and Remote Control

This Portable Air Conditioner is designed to be operated in cooling mode, fan mode, or dehumidifying mode. When switching between these functions keep an interval of at least 3 minutes between each ON/OFF. Allow the refrigerant to settle by leaving the appliance to stand for two hours after transport or after the unit has been on its side. Ensure the unit is in the OFF setting before connecting it to the main supply. When the appliance is powered on for the first time, it will beep, and then the unit will be on standby.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-11

  1. Power Button
    Press the button to turn the unit ON and OFF.
  2. Mode Button
    Press the button to switch between Cooling → Dehumidification → Fan modes.
  3. Sleep Button
    In the Cooling Mode, Press the UP and Fan buttons together to turn on the sleep mode. The unit will work in Energy-Saving and quiet mode.
    Note: You can not use sleep mode in the Dehumidifying or Fan modes.
  4. 4 & 5. Temperature Setting Buttons
    To set the desired temperature, press the UP or DOWN button. The range is 16-31oC. This function is not available in fan or dehumidification mode. Simultaneously press both buttons to switch between Celsius (℃) and Fahrenheit (℉).
  5. Fan Speed Button
    In cooling or fan mode press the button to select between high or low fan speed operation. In dehumidification mode, the fan will automatically be set to low-speed operation. This cannot be changed.
  6. Timer Setting Button
    The timer can be set to turn the unit ON or OFF for 1-24 hours. To set the timer to turn the unit OFF, press the TIMER button while the unit is operating and set the desired number of hours before the unit turns off. To set the timer to turn the unit ON, press the TIMER button while the unit is in standby and set the desired number of hours before the unit turns on.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-12
Remote Control

The remote control has the same functions as the unit control panel.

Care and Maintenance

Manual Drainage
  • The unit will stop once it has filled with water. Turn off the unit and unplug the power plug.
  • Move the unit carefully, so as not to spill the water in the water pan at the bottom of the body.
  • Find a place to drain the water or place a bucket below the water outlet on the back of the unit.
  • Unscrew the drainage cover and unplug the water plug, the water will automatically flow into the water container. During drainage, the body can be tilted slightly backward.
  • When the water is discharged, replace the water plug, and re-tighten the drainage cover.
  • Allow the unit to sit for at least 5 minutes before turning it back on.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-13

Do not use this Air Conditioner with a programmer, remote-control system, separate timer or any other device that switches the Air Conditioner on automatically.

CARE AND CLEANING

Clean the upper filter screen frame
  • Unscrew the screw fixing the EVA filter screen and the rear housing to remove the EVA filter screen (as shown in the below figure)
  • Put the EVA filter screen into warm water with neutral detergent (about 40 ℃ / 104 ℉) and dry it in the shade after rinsing clean.Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-14
NEVER USE UNIT WITHOUT THE AIR FILTER.
  • The exterior may be cleaned with a soft, dry cloth. If the device is extremely dirty wipe the device with a slightly damp (not wet) cloth. Never spray the device with water.
  • DO NOT immerse the unit in water and never allow water to enter the motor housing.
  • DO NOT use harsh chemicals to clean the unit.
  • Do not attempt to dismantle the Air Conditioner. There are no user-serviceable parts. For service or repair, contact an authorized electrical service technician.
STORAGE

To store the unit, remove the plug from the socket. Remove the rubber plug from the drainage hole at the bottom of the unit, and connect a drain hose to the lower fixing clip. All the water in the water tank will drain out. Allow the Container and the Air Conditioner to dry completely. Clean the air filter. Refit the rubber plug. Store the device in a dust-free location, preferably covered with a sheet of plastic.

Troubleshooting

Problems Reasons Solutions
 

 

 

 

 

 

The air conditioner does not work.

There is no electricity. Turn it on after connecting it to a

socket with electricity.

The water-full indicator will flash. Discharge the water inside.
The ambient temperature is too

low or too high

Recommend to use the machine

in at the temperature of 7-35 ℃

(44-95 ℉).

In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is

higher than the set temperature.

 

 

Change the set temperature.

In dehumidification mode, the ambient temperature is low. The machine is placed in a room with an ambient temperature of

greater than 17 ℃ (62 ℉).

 

 

 

The  cooling  or  heating

effect is not good

There is direct sunlight. Pull the Curtain.
Doors or windows are open; there are a lot of people; or in cooling mode, there are other

sources of heat.

 

Close doors and windows.

The filter screen is dirty. Clean or replace the filter screen.
The air inlet or outlet is blocked. Clear obstructions.
Loud Noise The air conditioner is not placed

on a flat surface.

Put the air conditioner on a flat

and hard place (to reduce noise).

 

Compressor does not work.

Frost production starts. Wait for 3 minutes until the temperature  is  lowered,  and

then restart the machine.

Overheat protection starts.
 

 

The remote control does not work.

The     distance     between     the machine and the remote control

is too far.

Move the remote control closer to the air conditioner, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote

control receiver.

Batteries are dead. Replace batteries.
Displays ‘E1’. The room temperature sensor is

abnormal.

Check  the  room  temperature

sensor and related circuitry.

Displays ‘E2’ The pipe temperature sensor is

abnormal.

Check the pipe temperature

sensor and related circuitry.

PROOF OF PURCHASE

To receive a warranty retain the receipt as proof of purchase. (Refer to the back of the booklet).

One Year Warranty

  • Thank you for purchasing this Goldair product. Your product is warranted against faults and manufacture when used in normal domestic use for a period of one year. In non-domestic use Goldair limits the voluntary warranty to three months.
  • Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault during the warranty period.
  • This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out by anyone other than a qualified electrical service technician.
  • PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.
  • The benefits to you given by this warranty are in addition to other rights and remedies available to you under a law in relation to the goods or services to which this warranty relates.
  • In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
  • In New Zealand, this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).

SUPPORT AND TECHNICAL ADVICE

Goldair – New Zealand

Monday – Friday 8 am-5 pm
Phone +64 (0)9 917 4000
Phone 0800 232 633
info@cdb.co.nz
www.goldair.co.nz

Goldair – Australia

Monday – Friday 8 am-5 pm
Phone +61 (0)3 9336 4423
Phone 1300 465 324
info@cdbgoldair.com.au
www.goldair.com.au

Goldair One-Year Warranty (IMPORTANT: Please complete and retain this warranty card)Goldair-BTU-2.9kW-Portable-Air-Conditioner-FIG-15

New Zealand
PO Box 100707,
North Shore Mail Centre, Auckland, 0745
www.goldair.co.nz

Australia
PO Box 574,
South Morang, Victoria, 3752
www.goldair.com.au

Documents / Resources

Goldair GCPAC10 10K BTU 2.9kW Portable Air Conditioner [pdf] Instruction Manual
GCPAC10 10K BTU 2.9kW Portable Air Conditioner, GCPAC10, 10K BTU 2.9kW Portable Air Conditioner, 10K BTU 2.9kW Portable AC, 2.9kW Portable AC, 10K AC, BTU AC, 2.9kW AC

References

Leave a comment

Your email address will not be published. Required fields are marked *