MINOSTON-logo

MINOSTON MP24Z Z Wave Plug 700 Series Dual Smart Plug for Outdoor

MINOSTON-MP24Z-Z-Wave-Plug-700-Series-Dual-Smart-Plug-for-Outdoor-product

Specifications

  • 125V, 60Hz
  • Max. 15A GP
  • 15A Resistive
  • 1000W Incandescent
  • 1000W Tungsten
  • 1/3 HP
  • TYPE 3R Enclosure Rainproof
  • LED indicator
  • White: Light status indicator
  • White: ADD / Inclusion
  • Independently controlled Channel 1
  • Independently controlled Channel 2
  • Program button
    • Press 1x: Manually
    • Press 3x: Z-Wave Network configuration
    • Reset: Press the button twice then hold it for 10 seconds

Product Usage Instructions

Adding Device To Z-Wave Network for QR CODE

To add the Z-Wave Outdoor Plug to your Z-Wave network using a QR code, follow these steps:

  1. Scan the QR code provided on the packaging box or visit www.minoston.com.
  2. Follow the instructions provided on the website to add the device to your Z-Wave network.

Z-Wave Network Configuration

To configure the Z-Wave network for the Z-Wave Outdoor Plug, follow these steps:

  1. Ensure that your Z-Wave-certified controller is ready for network configuration.
  2. Press the manual/program button on the smart plug three times quickly.
  3. Wait for the Z-Wave network configuration process to complete.

Removing the Device from Z-Wave Network

To remove the Z-Wave Outdoor Plug from your Z-Wave network, follow these steps:

  1. Follow the instructions provided by your Z-Wave-certified controller to remove a device from the network.
  2. Once the controller is ready to remove the device, press the manual/program button on the smart plug three times quickly.

Factory Default

To restore the Z-Wave Outdoor Plug to its factory default settings, follow these steps:

  1. Press the manual/program button twice quickly.
  2. Hold the button for at least 10 seconds.
  3. The light will flash once to indicate a successful reset.

FAQ

  • Q: Can I use this plug to control medical or life support equipment?
    • A: No, this device should never be used to control the on/off status of medical and/or life support equipment.
  • Q: What should I do if I have questions or need assistance?
    • A: If you have any questions or need assistance, please contact us at ask@minoston.com or visit www.minoston.com.
  • Q: Are there any important safety instructions?
    • A: Yes, please read and follow all safety instructions provided with the product. Do not use an extension cord. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

LED indicator

MINOSTON-MP24Z-Z-Wave-Plug-700-Series-Dual-Smart-Plug-for-Outdoor-fig1

Specifications

  • 125V, 60Hz, Max. 15A GP
  • 15A Resistive
  • 1000W Incandescent
  • 1000W Tungsten
  • 1/3 HP
  • TYPE 3R Enclosure
  • Rainproof

Adding Device To Z-Wave Network for QR CODE

MINOSTON-MP24Z-Z-Wave-Plug-700-Series-Dual-Smart-Plug-for-Outdoor-fig3

                                                                                   Z-Wave Network Configuration

Add Device To Z-Wave Network

  1. Follow the instructions for your Z-Wave-certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press the Manual/ Program button on the smart plug
  3. times quickly. The blue LED will blink quickly. Auto-add mode: LED will blink within 30 seconds after first plugged in. Now, you have completed control to turn your fixture ON/OFF according to groups, schedules and interactive automation programmed by your controller. If your Z-Wave-certified controller features remote access, you can control your fixture from your mobile devices.

To Remove The Device

  1. Follow the instructions for your Z-Wave-certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, press the manual/program button on the smart plug
  3. times quickly.

Factory Default

Manual: Click the button twice quickly then hold for at least 10 seconds. (Light flashes once when reset successfully.) Host reset: Remove it from hub the device will be restore to factory default

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. This device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference  by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.

CAUTION – PLEASE READ!

This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsureor uncomfortable about performing this installation consult a qualified electrician.

MEDICAL EQUIPMENT

Please DO NOT use this plug to control Medical or Life Support equipment. This device should never be used to control the On/Off status of Medical and/or Life Support equipment.

OTHER WARNINGS

Risk of Fire / Risk of Electrical Shock / Risk of Burns

IMPORTANT SAFETY INSTRUCTIONS

  1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
  2. Read and follow all instructions that are on the product or provided with the product.
  3. do not use an extension cord.
  4. Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring and clearances from power and lighting conductors.
  5. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards, including fire-rated construction.
  6.  do not install or use within 10 feet of a pool
  7. do not use it in a bathroom

WARNING

Risk of Electric Shock.
When used outdoors, install only to a covered Class A GFCI-protected receptacle that is weatherproof with the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power unit andcord do not interfere with completely closing the receptacle cover.

WARNING

Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.

WARNING

Risk of Electric fire. install only to a receptacle protected by 20A branch circuit over current protection.

SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions.

If you have any questions, please contact us at

MINOSTON-MP24Z-Z-Wave-Plug-700-Series-Dual-Smart-Plug-for-Outdoor-fig2

Scan the QR code or visit ask@minoston.com and www.minoston.com

Documents / Resources

MINOSTON MP24Z Z Wave Plug 700 Series Dual Smart Plug for Outdoor [pdf] User Manual
MP24Z Z Wave Plug 700 Series Dual Smart Plug for Outdoor, MP24Z, Z Wave Plug 700 Series Dual Smart Plug for Outdoor, 700 Series Dual Smart Plug for Outdoor, Dual Smart Plug for Outdoor, Smart Plug for Outdoor, Plug for Outdoor

References

Leave a comment

Your email address will not be published. Required fields are marked *