Product Specifications

  • Downrod
  • DCMotor
  • Light kit
  • Pan
  • Lampshade
  • Mounting Bracket
  • Woodscrews
  • Bladescrews*6
  • Weight blocks
  • Blades *3

Product Usage Instructions

Installing the Downrod:

  1. Take the cotter pin and the cross pin off the downrod assembly.
  2. Insert the downrod through the canopy and the yoke cover, then feed the motor wires through the downrod.
  3. Loosen the 2 downrod jam screws on the yoke cover, then insert the downrod assembly into the yoke cover.

Securing the Downrod:

  1. Insert the cross pin through the yoke cover and the downrod and secure it with the cotter pin.
  2. Tighten the downrod jam screws to secure the downrod fully.

Changing the Downrod:

  1. Rotate the fan so that the groove on the ball is set into the ridge of the mounting bracket.
  2. Insert the receiver into the mounting bracket and connect the wires according to the wire color.
  3. After making the wire connections, leave the receiver in the mounting bracket and secure the canopy to the bracket.

Installing the Light Kit:

  1. Connect the 2-pin male terminal connector from the light kit to the 2-pin female terminal connector from the fan.
  2. Loosen the 3 screws on the switch cap.
  3. Attach the light kit pan by setting the 3 screws into the light kit pan’s keyholes.
  4. Tighten the 3 screws to secure the light kit pan.

Frequently Asked Questions (FAQ):

Q: How do I change the downrod?
A: To change the downrod, follow these steps:

  1. Rotate the fan to align the groove on the ball with the ridge of the mounting bracket.
  2. Insert the receiver into the bracket and connect wires based on color coding.
  3. Secure canopy to bracket after wiring is complete.

SAFETY RULES 

  1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before beginning.
  2. All wiring must be by the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
  3. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device.
  4. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to the outlet box marked “Acceptable for Fan Support of 45kg (99.12 lbs.) Or Less” and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of light fixtures are not acceptable for fan support and may need to be replaced. Due to the complexity of the installation of this fan, a qualified licensed electrician is strongly
    recommended.
  5. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 45KGS. Use only UL-listed outlet boxes marked FOR FAN SUPPORT.
  6. The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
  7. Avoid placing objects in the path of the blades.
  8. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
  9. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
  10. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
  11. Electrical diagrams are for reference only.
  12. The fan is suitable for indoor use only.

TOOLS REQUIRED FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (1)

UNPACK AND INSPECT FAN CAREFULLY TO BE CERTAIN ALL CONTENTS ARE INCLUDED FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (2)

WARNING : BLADES SHOULD BE AT LEAST 7 FEET FROM FLOOR

  1. Please turn off the main switching power supply
    See Fig.1
  2. The mounting bracket is fastened to the wooden ceiling with wooden screws. (Ceilings must be capable of carrying 30)
    See Fig.2
  3. The mounting bracket is locked with an expansion screw on the concrete ceiling. See Fig.3
    Loosen the bottom screws from Mounting Bracket.
    Do not remove the screws.

FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (3)

Installing Downrod and Yoke

  1. Take the cotter pin and the cross pin off the down rod assembly.
  2. insert the down rod through the canopy and the yoke cover, then feed the motor wires through the downrod.
  3. Loosen the 2 down rod jam screws on the yoke cover, then insert the down rod assembly into the yoke cover.
  • insert the cross pin through the yoke cover and the downrod and secure it with the cotter pin.
  • Tighten the down rod jam screws to secure the down rod fully.

FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (4)

HOW TO CHANGE DOWNROD

Change Downrod For 10 Inch (OPD
The Ceiling Fan comes with one 5 inches standard downrod which is preassembled and attached to the hanger ball, one longer 10 inches down rod is also included for higher ceilings. If you need a different downrod length, please follow these steps:FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (5)

  1. Loosen the hanger ball from the downrod by removing the set screws.
  2. Slide the downrod ball off of the downrod and remove the pin.
  3. Re-install the pin into the extended downrod, and slide the downrod ball up to the top of the downrod.
  4. Re-install the set screw to secure the downrod ball to the downrod.

MOUNT FAN TO BRACKET

Hanging the fan
Lift fan assembly onto mounting bracket.
Rotate the fan so that the groove on the ball is set into the ridge of the mounting bracket

FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (13)

INSTALL THE REMOTE CONTROL

Make wiring connections from the house and the motor to the remote receiver as shown right.FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (8)
Note: the remote receiver must match the same code controlFUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (9)

Insert the receiver into the mounting bracket and connect the wire according to the wire color. See the label diagram above. (If the fan does not have a light, there is no need to connect the light wires)
After making the wire connections, leave the receiver in the mounting bracket and secure the canopy to the bracket.

Insert the receiver into the mounting bracket.
NOTE: Carefully tuck the wire connections into the outlet Box.FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (10)

CANOPY INSTALLATION

Note: The two screws are pre-installed onto the mount bracket for the canopy installation.

  1. Push the canopy up until the two pre-screwed screws on the mounting bracket are set within the two keyholes of the canopy.
  2. Rotate the canopy slightly until the two pre-installed screws are set into the narrow end of the keyholes. Once they are set, tighten both the screws.

FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (11)

BLADE INSTALLATION 

Attach blades to the motor by using the screws provided in the hardware bag. (* Repeat step until all 3 blades are installed firmly.)FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (12)

LIGHT KIT INSTALLATION 

  1. Connect the 2-pin male terminal connector from the light kit to the 2-pin female terminal connector from the fan.
  2. Loosen the 3 screws on the switch cap.
  3. Attach the light kit pan by setting the 3 screws into the light kit pan’s keyholes.
  4. Rotate the light kit pan slightly until the 3 screws are set into the narrow end of the keyholes.
  5. Tight the 3 screws

FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (13)

Attach the Lampshade by screwing it onto the tight kit pan clockwise.FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (14)

Turn on the power at the breaker box – your fan is ready for operation.FUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (15)

USE OF REMOTE CONTROLFUMUME-52-Inch-Indoor-Outdoor-Ceiling-Fan-with-Lights-Remote-Control-FIG- (16)

  1. LED indicated light
  2. on/off the fan
  3. Timing control of the fan
  4. Optional: Anti-theft function(Press and hold for 3 seconds to turn on this function)(The light is ON for about 5~20 minutes every 2 hours, Simulate use while away from home)
  5. Silent Mode (Press and hold the button for 3 seconds to turn silent mode on. In silent mode, there is no beep sound when pressing the button)
  6. Natural wind
  7. Speed of the fan
  8. Direction of the fan (reverse switch)
  9. Turn off the light (This product( if no light kit) does not have this function)
  10. Turn on the light (This product( if no light kit) does not have this function)
  11. 1.SV AAA battery x 2pcs This product does not contain batteries

KINDLY REMINDERS

  1. Connecting mode is a mode used to connect the remote to the receiver. Turn ON the power supply and within 5 seconds press and hold the power button “@” in the direction of the receiver. It will load after two “beep” sounds. This means the connection is successful and will work normally(PS: Connecting mode is not accepted after turning ON the power supply for over 3 seconds. Please turn off the power supply and try it again )
  2. When the remote cannot control the receiver, please check that the battery is positioned correctly in the battery slot and ensure they have a charge.
  3. When the remote cannot control the receiver, please check if there are any remote control devices nearby,and check if they are working, which could be disrupting the connection with the remote.
  4. The low voltage of the battery will affect the sensitivity of the remote and the signal reception (the indicated light getting dimmer is a warning when the battery is low). Replace the battery when this accords.
  5. Please remove the batteries if the remote is not used long.
  6. For the maximum load of lighting see the above “POWER PARAMETER LIST”
    PS: please connect the ground wire correctly, otherwise it may cause the light micro-light or flash.
  7. When installing the fan,the fan ceiling cover don’t press the antenna(or other wire),it is easy to break down the wire and short-circuit.

TROUBLESHOOTING

CEILING FAN NOT WORKING:
Before checking, please note: Make sure the main power is off.

  1. If the fan is powered on, the receiver does not have any prompt sound.
    Please check whether the input power supply is powered on or check the connections.
  2. If the fan makes a “beep” sound after powering on, but nothing happens when you press the remote control. Please refer to the manual of the remote control to learn the pairing code for the remote control receiver.
  3. If the fan is powered on, press the remote control button, and it makes a sound, but the fan does not rotate. Please do not press the remote control multiple times.
    Please turn off the power immediately, and check whether the red, gray, and brown wires between the motor and the receiver are loose. Or cut off the terminal wire of the motor and the terminal wire of the receiver and connect them tightly with electrical tape and try again.
  4. If the above methods still cannot solve the problem, please contact the After-sales service.

CEILING FAN MAKING NOISE: 

  1. If the motor makes a friction sound when it rotates, please tap the edges of the four screws of the motor with a light rubber hammer. (If you can’t solve it, please get in touch with customer service)
  2. Make sure that all the screws of the motor casing and the screws at the connection of the downrod are fastened.
  3. Please ensure the screws securing the fan blade bracket to the motor hub are tight.
  4. Make sure the wire nut connections are not rubbing against each other or the inside wall of the switch housing.
  5. Allow a 24-hour “run-on period”. Most of the noise associated with new equipment will disappear during this time.
  6. If using the optional lighting kit, ensure the screws holding the glassware are tight. Also, check that the bulb is secure.
  7. Make sure that the upper canopy has a certain distance from the ceiling and should not touch the ceiling.
  8. If the above methods still cannot solve the problem, please don’t hesitate to contact After-sales service.

CONTACT INFORMATION

We want to hear your voice! Feel free to touch base if you encounter any issue when using our product(s) or want to know more about our brand.
We will be more than happy to provide top-notch pre-sales & after-sales service 24/7.
FUMUME@OUTLOOK.COM

Documents / Resources

FUMUME 52 Inch Indoor Outdoor Ceiling Fan with Lights Remote Control [pdf] Instruction Manual
52 Inch Indoor Outdoor Ceiling Fan with Lights Remote Control, 52 Inch, Indoor Outdoor Ceiling Fan with Lights Remote Control, Ceiling Fan with Lights Remote Control, Lights Remote Control, Remote Control

References

Leave a comment

Your email address will not be published. Required fields are marked *