CLEERLINE SSF logo

SSF-TKITE-100 / SSF-TKITE-1SM /SSF-TKITE-1MM
SSF™ Fiber Test Kit
Manual

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit

Warning
To avoid the risk of eye damage, do not look into the laser beam when the unit is on.

SSF-LS100SM: Single-Mode Optical Light Source
SSF-LS100MM: Multimode Optical Light Source

WARNING

  1. Do not look into the laser beam when the unit is on.
  2. To prevent damage to the instrument, do not use it under high temperature, high pressure, wet, or other prohibited conditions.
  3. Do not attempt to take apart or repair the instrument.

Quality Assurance
Each unit meets the declared specification.
Note:
Technical parameters are subject to change without notice.

Overview

The SSF-LS100SM Single Mode optical light source provides single to tri wavelength output, including 1310/1550nm wavelengths for single-mode fiber.
The SSF-LS100MM Multimode optical light source provides single to tri wavelength output, including 850/1300nm wavelengths for multimode fiber.
Together with the SSF-PM100 power meter, the optical light source provides an accurate test solution for single-mode and/or multimode optical fiber networks.

Model: SSF-LS100SM Single Mode
Wavelength: 1310/1550nm
Output Power: ≥ -7dBm
Model: SSF-LS100MM Multimode
Wavelength: 850/1300nm
Output Power: ≥ -7dBm

Features

  • Single to a tri-wavelength combination
  • The continuous and modulated signal
  • Real-time display of battery level and low power indication
  • Backlight function
  • Auto shut-off function
  • Alkaline battery operation

Specifications

Type SSF-LS100SM Light Source
Wavelength (nm) 1310 / 1550
Emitter Type FP-LD
Output Power (dBm) ≥-7dBM @1310 / 1550nm
Output Power ±0.04 @ 20°C @ 15 min
Modulation CW/270Hz/1KHz/2KHz @ others
Fiber Type SM
Connector SC
Power Supply AAA 1.5V (3pcs batteries)
Operating Temperature (°C) -10 – +50, 0 to 95% RH (no condensation)
Storage Temperature (°C) -25 – +70, 0 to 95% RH (no condensation)
Battery Life (h) 40
Dimension (mm/in) 125x65x29 / 4.92×2.56×1.14
Weight (g/oz) 160 / 3.74
Type SSF-LS100MM Light Source
Wavelength (nm) 850 / 1300
Emitter Type FP-LD
Output Power (dBm) ≥-7dBM @850/ 1300nm
Output Power ±0.04 @ 20°C @ 15 min
Modulation CW/270Hz/1KHz/2KHz @ others
Fiber Type MM
Connector SC
Power Supply AAA 1.5V (3pcs batteries)
Operating Temperature (°C) -10 – +50, 0 to 95% RH (no condensation)
Storage Temperature (°C) -25 – +70, 0 to 95% RH (no condensation)
Battery Life (h) 40
Dimension (mm/in) 125x65x29 / 4.92×2.56×1.14
Weight (g/oz) 160 / 3.74

Functions

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - Functions

1

SM/MM

Label Area: Light Source will read SM (Single Mode) or MM (Multimode) depending on model. Choose SM  for single-mode testing (1310/1550nm) or MM for multimode testing (850/1300nm).
Power On/Off: Press and hold for 1 second to turn the unit on or off.

2

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 Auto Shut-Off Selection: While the unit is on, press this key quickly to turn the auto shut-off function on or off. When auto shut-off is active the unit will automatically shut off after ten minutes of idle.

3

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon3 Wavelength Selection: Press this key to change the wavelength, shown in the top left corner of the screen.

4

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon4 Modulation: Press this key to switch modulation between continuous and modulated light.
Modulated light frequency: 0.27, 1.00, 2.00 KHZ.
Continuous light mode displays — kHz (0 kHz).

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - Source1

1

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon5

Wavelength: (nm)
1310/1550: Single-mode fiber testing (SSF-LS100SM)
850/1300: Multimode fiber testing (SSF-LS100MM)

2

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon6 Battery Indicator: displays when battery power is in use. The capacity shown will decrease with battery power. Replace
batteries as needed.

3

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 Auto Shut-off: The light source will automatically shut off when idle for ten minutes. Press the power button ( CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2)
quickly turn the Auto-Off function on or off.

4

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon7 Frequency: (kHz) 0.27, 1.00, or 2.00 kHz. The dashed line indicates Continuous Wave Mode (CW)

5

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon8 Output Power: (dBm)

Operation

Warning

  1. Do not look into the laser beam when the unit is on. Light emitted is infrared and not visible to the human eye. To avoid the risk of eye damage, do not look into the laser at any time when the unit is active.

Turning the Unit On/Off

  1. PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 and hold for 1 second to turn on the unit. Press and hold for two seconds to power off the light source.
  2. To turn the auto shut-off function on or off, with the light source turned on pressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2
  3. The unit’s automatic backlight will be enabled when the light source is turned on. It will turn off after 1 minute of inactivity. Press any key to reactivate.

Laser Output

  1.  PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon3 to choose wavelength.
  2. PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon4 to select modulation.
  3.  The light source will output the desired laser settings.

Battery Replacement

  1. If the battery level is low, turn off the unit immediately and replace the batteries.
  2. Remove the batteries if the light source is not in use for an extended period of time.

Maintenance and Troubleshooting

  1. Always keep the connector ports of the light source clean.
  2. Use the regulated optical connector for testing.
  3. Shut off the power and cover the laser with a dust-proof cap after use.
  4. Plugin/remove adapters carefully.
  5.  Regularly clean the connector.
  6. Remove the batteries when the light source is not in use for extended periods of time.

Troubleshooting

Issue Possible Reason Solution
Faint screen display/No backlight Low battery power Replace the batteries.
Unit fails to turn on Low battery power or battery inserted incorrectly (A) Replace the battery
(B) Re-insert the battery
The display fails to appear Low battery Restart or replace batteries
The LCD screen will not change Low battery Replace batteries
No laser power Laser is off Adjust CW/Hz

Warning

  1. Ensure the connector is clean before testing.
  2.  Do not look into the laser beam when the unit is on.
  3. Cover with laser with the dust-proof cap when not in operation.

Warranty

Caution: Do not attempt to repair as doing so will void the warranty.
This Optical Light Source is covered by an 18-month warranty

  1. We warrant that this power meter will be free from defects in material and workmanship for 18 months. Should the device fail at any time during this warranty period, we will, at our sole discretion, replace and repair or refund the purchase price of the product. The worth of the repair or replacement will not be higher than purchasing price of this unit.
  2. If device issues cannot be solved by the troubleshooting methods, please contact us or the local distributor directly.
  3. We will repair or replace the unit free of charge in case of defects in production, workmanship, or material. This warranty only applies to the unit under normal operation without any damage or misuse/abuse.
  4. The shipping costs incurred by repair or replacement for the unit under warranty will be shared by both parties.

SSF-PM100
Optical Power Meter

Warning

  1. When using a light source with a power meter, do not look into the laser beam when the unit is on. Light emitted is infrared and not visible to the human eye. To avoid the risk of eye damage, do not look into the laser at any time when the unit is active.

Overview

The SSF-PM100 is a handheld optical power meter that can be used for absolute optical power measurements and relative loss measurements on both single-mode and multimode fibers.

Model
Wavelength: 850, 1300, 1310, 1490, 1550, 1625nm
Measurement Range: -70 – +10dBm
Features

  • High measurement accuracy and display resolution
  • Quick response and measurement; real-time display of output power
  • Wide measurement range (80dB)
  • Six calibrated wavelengths
  • Absolute and relative power measurements
  • Real-time monitoring and display of battery level
  • Auto shut-off function
  • Backlight function
  • Alkaline battery operation

Specifications

Wavelength (nm) 800 – 1650nm
Detector Type InGaAs
Measurement Range (dBm) -70 – +10 -50 – +26
Accuracy <±3% (-10dBm, 22°C)
Calibrated Wavelength (nm) 850, 1300, 1310, 1490, 1550, 1625
Resolution (dB) Linearity: 0.1%, Non-linearity: 0.01 dBm
Optical Connector SC, LC with Adapters
Power Supply Alkaline Battery (3 AAA 1.5V batteries)
Battery Operating Time 120 h (without backlight)
Operating Temperature (°C) -10 – +50
Storage Temperature (°C) -20 – +70
Relative Humidity 90% (+30°C)
Dimension (mm / in) 125x65x29 / 4.92×2.56×1.14
Weight (g / oz) 160 / 5.64

Functions

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - Functions1

1

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 Power On/Off: Press and hold for 2 seconds to turn the unit on or off.
Auto Shut-Off Selection: Press this key quickly to turn the auto shut-off function on or off. When auto shut-off is active the unit will automatically shut off after ten minutes of idle.

2

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon9 REF: Press and hold this key to store the current power value as the reference value.
Quickly press this key to enter the relative measurement mode. This model compares the current power with the
reference power and shows the relative power value in dB.

3

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon10 Measurement Setting: Press this key to switch between the absolute measurement (dBm) and relative measurement (nW) of the optical power.

4

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon3 Wavelength Selection: Press this key to select one of the 6 calibrated wavelengths

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - Meter

1

nm

Wavelength: (nm)
850/1300: Multimode fiber testing
1310/1550: Single-mode fiber testing

2

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon6 Battery Indicator: displays when battery power is in use. The capacity shown will decrease with battery power. Replace batteries as needed.

3

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 Auto-off: the power meter will automatically shut off when idle for ten minutes. Press the power button ( ) quickly to turn the Auto-Off function on or off.

4

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon7 Frequency: (kHz) 0.27, 1.00, or 2.00 KHz.

5

Power Value: (dBm, nW, dB)

6

CLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon9 Reference Power Value: (dbm)

Operation

Turning the Unit On/Off

  1. PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2 and hold for 1 second to turn on the unit. Press and hold for two seconds to power off the power meter.
  2. To turn the auto shut-off function on or off, with the light source turned on press theCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon2.
  3. The unit’s automatic backlight will be enabled when the light source is turned on. It will turn off after 1 minute of inactivity. Press any key to reactivate.

Absolute Power Measurement (Setting Reference Value)

  1. Place appropriate reference cable (LC or SC and either single-mode or multimode) between units. If using an LC reference cable, install appropriate adapters and then connect the cable.
  2. Turn on both devices. Allow the power meter to stabilize for 1-2 minutes.
  3.  Match the wavelength on the power meter to the light source by pressingCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon3. For multimode, 850nm is recommended. For single-mode, 1310nm is recommended.
  4. PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon10 to choose the power display unit (dBm or nW). Set to dBm.
  5. The power meter will then display the tested power value in the center of the screen. Set this as the reference value by pressing and holdingCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon9 for two seconds. The screen will then read 0.00dBM

Relative Power Testing (Finding Loss Value)

  1. Perform the steps above to set the reference value.
  2.  Unplug the reference cable from the power meter side only.
  3. Attach female to female adapter for connector type under test to reference cable.
  4. Plug cable to be tested between the female adapter and power meter.
  5. The screen will display the loss in dB for the cable under test. The optical loss will appear as a negative value (i.e. -0.57 dB).
  6. PressCLEERLINE SSF Series SSF TKITE 100 Fiber Test Kit - icon10review to review the current reference power value.

Maintenance and Troubleshooting

  1. Always keep the connector ports of the power meter clean.
  2. Use the regulated optical connector for testing.
  3.  Shut off the power and cover the laser with a dust-proof cap after use.
  4. When using an AC adapter, ensure the power supply is within the required voltage range.
  5. Remove the batteries when the power meter is not in use for extended periods of time

Battery Replacement

  1. If the battery level is low, turn off the unit immediately and replace the batteries.
  2. Remove the batteries if the light source is not in use for an extended period of time.

Troubleshooting

Issue

Possible Reason

Solution

Faint screen display/No backlight Low battery power Replace the batteries.
Unit fails to turn on Low battery power or battery inserted incorrectly (A) Replace the battery (B) Re-insert the battery
Display fails to appear Low battery Restart or replace batteries
LCD screen will not change Low battery Replace batteries
No laser power Laser is off Adjust CW/Hz

Warranty

Caution: Do not attempt to repair as doing so will void the warranty.
This Optical Power Meter is covered by an 18-month warranty

  1. We warrant that this power meter will be free from defects in material and workmanship for 18 months. Should the device fail at any time during this warranty period, we will, at our sole discretion, replace and repair or refund the purchase price of the product. The worth of the repair or replacement will not be higher than purchasing price of this unit.
  2. If device issues cannot be solved by the troubleshooting methods, please contact us or the local distributor directly.
  3.  We will repair or replace the unit free of charge in case of defects in production, workmanship, or material. This warranty only applies to the unit under normal operation without any damage or misuse/abuse.
  4. The shipping costs incurred by repair or replacement for the unit under warranty will be shared by both parties.

Warning

  1. Ensure the connector is clean before testing.
  2.  Do not look into the laser beam when the unit is on.
  3. Cover laser with the dust-proof cap when not in operation.

Documents / Resources

CLEERLINE SSF Series SSF-TKITE-100 Fiber Test Kit [pdf] User Manual
SSF Series, SSF-TKITE-100, SSF-TKITE-1SM, SSF-TKITE-1MM, Fiber Test Kit

References

Leave a comment

Your email address will not be published. Required fields are marked *