Carrier-logo

Carrier COR TP-WEM01 Smart Thermostat

Carrier-COR-TP-WEM01-Smart-Thermostat

View all Carrier thermostat manual

Product Data

Carrier-COR-TP-WEM01-Smart-Thermostat-1

INTRODUCTION

From the people who invented modern air conditioning comes a thermostat that’s reinventing the way you manage your comfort and energy savings. Take control of your home with a fingertip or just let the Carrier Côrt thermostat do all the work for you. Whether you’re on the couch, on the road or even on the other side of the world, you can stay connected to the heart of your home from the palm of your hand.
With the Côr thermostat, homeowners saved an average of 20% on their heating and cooling energy costs.* Features like smart setback let the thermostat intelligently adapt beyond manual programming for greater efficiency, while still meeting your ideal comfort levels. Energy reports that show your system performance allow you to modify your settings to maximize savings. You’ll also receive customized tips to help you save even more.
Based on a 2012 third – party study comparing Carrier Côr™ technology to the estimated cost of a non – programmable thermostat set to 72° F at all times.

FEATURES/BENEFITS

  • ENERGY STAR smart thermostat
  • Apple HomeKit compatible
  • Smart Home / Away
  • Remote access via web portal or smartphone app
  • Energy reports and customized savings tips
  • Intelligent software adapts beyond manual programming for greater efficiency, while meeting ideal comfort levels by understanding home and system characteristics
  • Smartphone style, color touch screen
  • Indoor humidity sense and display
  • Local 4- day weather forecast
  • HVAC system alerts and maintenance reminders display dealer contact information
  • 7- day programmability with Guided Scheduling, Comfort
    Profiles and Touch- n- Go Features
  • Heating/Cooling Smart Setback
  • Super Dehumidification, Cool to Dehumidify S Comfort Heat Pump System™ Feature
  • Auxiliary Heat During Defrost
  • Fan Optimization
  • Air Circulation (minimum time per hour)
  • Free Cooling with a Ventilator
  • Window Protect with a Humidifier
  • Internal Occupancy Sensor

PRODUCT DATA INFORMATION

Equipment Capability

  • 24VAC (low voltage) systems
  • Up to 2 stages of heat (for conventional systems) OR
  • Up to 4 stages of heat for heat pump/Aux heat systems, (1 or 2 stages + 1 or 2 stages auxiliary heat, Intelligent heat staging capable)
  • Andupto2stagesofcool
  • Hybrid Heat dual- fuel systems
  • Geothermal systems
  • Boiler/hot water system
  • Accessories: humidifier, dehumidifier, or ventilation device

Physical Characteristics

  • Dimensions: 4” x 4” x 1” (See drawing exact dimensions)
  • Mounting: Horizontal

Electrical

  • Input volts/amps: 24VAC, 3 VA minimum, RC/RH compatible

Environment

  • Operating temperature/Relative humidity: 32_F(0_C) to 130_F (40_C), 95% RH non- condensing
  • Storage temperature/Relative humidity: – 40_F(-40_C) to 134_F(57_C), 95% RH non- condensing

Wiring Requirements
S Standard 18 to 22 gauge, local wiring codes supersede.

OPERATIONAL INFORMATION

Heating / Cooling Setpoints
The heating setpoint range is 50_F(10_C) to 90_F(32_C). a selectable range of 2 – 6_F(2_F default) is enforced between heating and cooling setpoint temperatures. This is done by allowing one setting to “push” the other to maintain this difference.

Alerts & Reminders
The system helps managing routine maintenance and service through system alerts and reminders that can be set up to notify both the homeowner and the servicing dealer. Notifications are displayed on the thermostat, mobile app, web portal, and can be sent via email. Routine service, filter change, temperature alerts,and humidity alerts are just a few examples of the alerts and reminders that can be sent.
Equipment On Indicators
When cooling equipment is ON, the idle screen displays (Cooling) When heating equipment is ON, the idle screen displays Heating. When auxiliary heating is ON (HP only) the idle screen displays (Heating) When just the fan is ON the idle screen displays (Fan on)
Equipment Operation
A wide variety of system settings like compressor time guards and auxiliary heat lock- outs are available to the installer. The installation menus are customized for the equipment type that is setup so if a heat pump is configured, only heat pump related settings are displayed.

Smart Setback
The Carrier Côr Thermostat takes the guess work out of setbacks with its Smart Setback feature. Set the minimum/maximum setback limits via the Cool To and Heat To settings and the thermostat will do the rest. The Smart Setback algorithm uses historical performance of the home along with the current outdoor conditions to calculate when to start heating/cooling in order to recover using the most efficient stage and heat source available.

REMOTE CONNECTIVITY

Compatibility

  • Broadband Internet
  • 802.11 b/g/n Wi- Fi network

Remote Access
The Carrier Côr Thermostat features remote access that allows you the freedom to manage and track your home energy consumption anytime and from anywhere. Whether you’re utilizing your personal Carrier Web Portal through a desktop computer, a tablet or one of Carrier’s smartphone apps, the power to manage your monthly energy usage is in the palm of your hand. Visit www.carrier.com/myhome from your Internetconnected device to access your personalized web portal or download the free app for your smartphone.

ENERGYSTAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.

MODEL NUMBER NOMENCLATURE

Carrier-COR-TP-WEM01-Smart-Thermostat-2

DIMENSIONS

Carrier-COR-TP-WEM01-Smart-Thermostat-3

(Shown with optional, large backplate)

ACCESSORIES

Wi- Fi is a registered trademark of the Wi- Fi Alliance Corporation

Copyright 2017 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

https://thermostat.guide/carrier/carrier-cor-tp-wem01-smart-thermostat-user-manual/

References

Leave a comment

Your email address will not be published. Required fields are marked *