safetrust Logosafetrust 8845-200 Wall Mount IoT Sensor8845-200 Quickstart Guide

In the box

safetrust 8845-200 Wall Mount IoT Sensor - In the box

safetrust 8845-200 Wall Mount IoT Sensor - Icon 1#6-32 x .375” Phillips flat head screw
Secures the IoT Sensor and the backplate together
safetrust 8845-200 Wall Mount IoT Sensor - Icon 2Nylon wall plugs
Used to brace the screws inside the wall
safetrust 8845-200 Wall Mount IoT Sensor - Icon 3#6 x 1.5” Phillips sheetmetal screws
For mounting wall bracket

Mounting Platesafetrust 8845-200 Wall Mount IoT Sensor - Mounting Plate

What you’ll need

Cable Installation Note
Power requirements: 12 Volts DC +/- 5% and 250mA at the endpoint (IoT Sensor) is required.
We advise not only selection of the right gauge and power quality, but integrators should confirm the power delivery is sufficient by checking power at the endpoints.
If existing cable is of higher gauge / lower capacity and cannot be replaced, Safetrust sensors are designed to operate at up to 24VDC.*
As a result, higher voltage at the power source is safe to use with IoT Sensors if the source and wiring implementation can safely support it and if it is compliant with local code.
* Safetrust recommends against using the same 24V power supply for both locks and IoT Sensors.

Power cable:

  • 18/2 for distances < 500 ft.
  • 16/2 for distances < 700 ft.
  • For distances up to 1000’, see Cable Installation Note above.

Data cable – Wiegand:

  • Cable, 5-12 conductor, 4 conductor Twisted Pair Over-All Shield and UL approved (<500ft)

Data cable – OSDP:

  • Belden 6381MD – 1Pr 24AWG Shielded Data + 18/2 Power OSDP CMP or equivalent (<500Ft)
  • Belden 6281MD – 1Pr 22AWG Shielded Data + 16/2 Power OSDP CMP or equivalent (<700Ft)

Tools and Supplies:

  • Metal or plastic junction box
  • Drill with various bits for mounting hardware
  • Additional tools and supplies as needed to connect sensor wires to associated system cable

Installation

Installation: Standard Wall Mount safetrust 8845-200 Wall Mount IoT Sensor - InstallationFor a wall mounted installation, begin by pre-drilling your holes and insert the nylon wall plugs provided to support the weight of the reader. Once secured, you can fix the backplate to the wall using the Phillips sheetmetal screws (#6 x 1.5”) provided.
Installation: Electrical Boxsafetrust 8845-200 Wall Mount IoT Sensor - Electrical BoxLocate the electrical box which will be recessed into the wall. You will see a top and bottom metal flange with holes which is used to secure the back plate to the wall. For this process you will need to use screws that are suitable for fixing to your specific electrical box (these are not supplied by Safetrust). Using the appropriate screws, fix the the backplate against electrical box so that it’s flush. safetrust 8845-200 Wall Mount IoT Sensor - Electrical Box 2safetrust 8845-200 Wall Mount IoT Sensor - Electrical Box 3The next step is to connect the wires as per the wiring table above. safetrust 8845-200 Wall Mount IoT Sensor - Electrical Box 4Once the backplate has been fitted and the wiring is complete, the IoT Sensor can be mounted to the wall as shown above. safetrust 8845-200 Wall Mount IoT Sensor - Electrical Box 5Complete the hardware installation by fixing the screw (#6-32 x .375” Phillips flat head screw) through the base of the reader.

Configuration

safetrust 8845-200 Wall Mount IoT Sensor - ConfigurationOpen the Safetrust Wallet App and select the Manage Sensor tab from the navigation. Make sure your system administrator has set you up with a role that has rights to configure a sensor.safetrust 8845-200 Wall Mount IoT Sensor - Configuration 2With the Manage Sensor tab open, bring the phone in range of the IoT Sensor and once visible from the App, highlight and select the “Configure” button. safetrust 8845-200 Wall Mount IoT Sensor - Configuration 3

  1. Choose an Identity System*.1.
  2. Specify the Type of access from the dropdown (eg. Door, Gate etc.) 2.
  3. Assign a short Name and Description using alphanumeric characters.3.
  4. Choose a Media Output for the sensor (the default is set to Wiegand).4.

*Note: Identity System must be previously created in the Safetrust Credential Manager portal by a system administrator.safetrust 8845-200 Wall Mount IoT Sensor - Configuration 3When the IoT Sensor information is saved successfully to Credential Manager and assigned to the Identity System, the new name will appear in the Manage Sensor tab with a unique serial number assigned.

Testing

safetrust 8845-200 Wall Mount IoT Sensor - Configuration 5

Access with cards
Status LED

safetrust 8845-200 Wall Mount IoT Sensor - Icon 6 Solid red
Indicates idle mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 7 Flashing red, blue, green
Power up mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 8 Flashing green
Card credential is read and transmitted through designated wiressafetrust 8845-200 Wall Mount IoT Sensor - Icon 10

Access with Mobile – BLE
Status LED
safetrust 8845-200 Wall Mount IoT Sensor - Icon 6 Solid red

Indicates idle mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 7 Flashing red, blue, green
Power up mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 9 Solid Blue
Mobile credential detected
safetrust 8845-200 Wall Mount IoT Sensor - Icon 8 Flashing green
Mobile BLE credential is read and transmitted through designated wiressafetrust 8845-200 Wall Mount IoT Sensor - Status LEDAccess with Mobile – NFC
Status LED

safetrust 8845-200 Wall Mount IoT Sensor - Icon 6 Solid red
Indicates idle mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 7 Flashing red, blue, green
Power up mode
safetrust 8845-200 Wall Mount IoT Sensor - Icon 8 Flashing green
Mobile BLE credential is read and transmitted through designated wires

Regulatory Information

FCC: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Canada Radio Certification: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
CE Marking: Safetrust hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

Support

Thank you for purchasing the Safetrust IoT Sensor Wall Mount.
If for any reason you need assistance with your installation, please contact your local Sales representative .
Sincerely – The Safetrust Team

safetrust Logosafetrust 8845-200 Wall Mount IoT Sensor - Icon 4 Safetrust Inc. | safetrust.com
sales@safetrust.com
www.safetrust.com/support
Last Updated: January 18, 2024

Documents / Resources

safetrust 8845-200 Wall Mount IoT Sensor [pdf] User Guide
DAEwgvfv60w, BAB78490suM, 8845-200 Wall Mount IoT Sensor, 8845-200, Wall Mount IoT Sensor, Mount IoT Sensor, IoT Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *