Quick logoGP2 500 GP2 500 Windlass
User Manual
High Quality Nautical Equipment
Quick GP2 500 GP2 500 WindlassROPE AND CHAIN ON A SINGLE GYPSY

TECHNICAL DATA

MODELS GP2 500 GP2 1200 / D – GP2 1200 FF
MOTOR OUTPUT 150W 250W
Motor supply voltage 12V 12V
Maximum pull 220 Kg (485,0 lb) 550 Kg (1212,5 lb)
Maximum working load 70 Kg (154,3 lb) 170 Kg (374,8 lb)
Working load 35 Kg (77,2 lb) 50 Kg (110,2 lb)
Current absorption @ working load (1) 29 A 35 A
Maximum chain speed (2) 38,9 mm (83,7 ft/min) 31,2 mm (102,4 ft/min)
Maximum chain speed @ working load (2) 28,5 mm (33,8 ft/min) 25,1 mm (82,3 ft/min)
Motor cable size (3) 4 mm2 (AWG 12) 10 mm2 (AWG 7)
Protection circuit breaker (4) 40 A 40 A
Deck thickness (5) 20 + 40 mm (3/4″ + 1″ 9/16)
Weight mod. without drum 6 kg (22,4 Ib) 8 kg (22,4 Ib)
Weight mod. with drum 9 kg (25,3 Ib)
Weight mod. Free Fall 10,9 kg (24,0 Ib)
  1. After an initial period of use.
  2. Measurements taken with a gypsy for a 8 mm chain.
  3. Minimum allowable value for a total length L< 20m (see pag. 18). Determine the cable size according to the length of the wiring.
  4. With circuit breaker designed for direct currents (DC) and delayed-action (thermal-magnetic or hydraulic-magnetic).
  5. On request, studs can be supplied for greater deck thicknesses.
Chain size 6mm 6mm 7mm 7MM 1/C 1/C 8 MM 8 mm 5/16°
DIN 766 ISO** DIN 766 ISO** G4 BBB DIN 766 ISO** G4
Rope size s 1/2″ (12,7 mm) 1/2° (12,7 mm) 1/2″ (12,7 mm) 1/2″ (12,7 mm) 1/2″ (12,7 mm)

(*) The values in the table regard a three-strand polyester rope with the “Quick® ” system rope/chain joint.
(**) ISO EN 818-3.

DIMENSIONS OF MODELS mm ( inch )

Quick GP2 500 GP2 500 Windlass - fig

Quick® reserves the right to introduce changes to the equipment and the contents of this manual without prior notice.
In case of discordance or errors in translation between the translated version and the original text in the Italian language, reference will be made to the Italian or English text.

BEFORE USING THE WINDLASS READ THESE INSTRUCTIONS CAREFULLY.
IF IN DOUBT, CONTACT YOUR NEAREST “QUICK® ” DEALER.
Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: the Quick ® windlasses are designed to weigh the anchor.Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon Do not use the equipment for other purposes. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconQuick ® shall not be held responsible for damage to equipment and/or personal injury, caused by a faulty use of the equipment.Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon The windlass is not designed for the loads that might occur in extreme weather conditions (storms).Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WEIGHING THE ANCHOR Turn on the engine. Always deactivate the windlass when not in use.Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon Check that there are no swimmers nearby before dropping anchor. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconThe splice between the rope and the chain must be tightly woven for the rope to slide easily into the gypsy shape. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconFor any problem or request, feel free to contact Quick ® Technical Service. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconFor improved safety we recommend installing at least two anchor windlass controls in case one is accidentally damaged. We recommend the use of the Quick ® hydraulic-magnetic switch as the motor safety switch. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconSecure the chain with a further device before starting the navigation. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconThe contactor unit or reversing contactor unit must be installed in a point protected from accidental water contact. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconAfter completing the anchorage, secure the chain or rope to fixed points such as chain stop- per or bollard. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconTo prevent accidental releases, the anchor must be secured. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconThe windlass shall not be used as the only secu- ring device. Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning IconIsolate the windlass from the power system during navigation (switch the circuit breaker off) and lock the chain securing it to a fixed point of the boat.

THE PACKAGE CONTAINS: windlass – reversing contactor unit – base gasket – drill template – handle – bolts and screws (for assembly) – user’s manual – conditions of warranty.
TOOLS REQUIRED FOR INSTALLATION: drill and drill bits: Ø 9 mm (23/64″) and Ø 11 mm (7/16”) – Ø 40 (1” 9/16) hollow mill; hexagonal wrenche: 13 mm.
“QUICK® ”ACCESSORIES RECOMMENDED: anchoring RL control board (mod. 800) – Waterproof hand helds R/C (mod. HRC 1002) – Foot switch (mod. 900) –  Hydraulic-magnetic circuit breaker – Anchor chain counter (mod. CHC 1102M and CHC1202M) – Radio control RRC (mod. R02, P02, H02).

INSTALLATION REQUIREMENTS: the windlass must be positioned with the gypsy aligned with the bow roller. Ensure that the upper and lower surfaces of the deck are as parallel as possible. If this is not the case, compensate the difference appropriately (a lack of parallelism could result in a loss of motor power). The deck thickness must be included among the figures listed in the table. In cases of other thicknesses it is necessary to consult a Quick ® retailer. There must be no obstacles under deck to the passage of cables, rope and chain; lack of depth of the peak could cause jamming.

Quick GP2 500 GP2 500 Windlass - fig 1

FITTING PROCEDURE: when the ideal position has been established, drill four holes using the drilling template provided.Remove excess material from the chain through  hole, ensuring the free passage of the chain or rope. Position the windlass lowering it from above deck and inserting the gasket between the deck and the base. Screw the stud  bolts, using the short threaded end, onto the base. Apply a medium grade locking product onto the thread. Fix the windlass by screwing the nuts onto the fixing studs.  Connect the supply cables from the windlass to the reversing contactor unit.Quick GP2 500 GP2 500 Windlass - fig 2

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: before wiring up, be sure the electrical cables are not live.

CONNECTION DIAGRAMQuick GP2 500 GP2 500 Windlass - fig 3

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: stay clear of the chains, ropes and gypsy. Make sure the electric motor is off when windlass is used manually (even when using the handle to disengage the  clutch). In fact people with windlass remote controls (hand-held remote control or radio-controlled systems) might accidentally operate it.
Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: secure the chain with a device before starting the navigation.
Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: do not operate the windlass by using the electrical power when the handle is inserted in the drum or into the gypsy cover.
Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: Quick® recommend using a circuit breaker designed for direct current (DC) with delayed-action (thermal-magnetic or hydraulic-magnetic) to protect the motor  supply line from overheating or short circuits. The circuit breaker can be used to cut off power to the windlass control circuit and so avoid accidental activation.

CLUTCH USE
MOD. FF (see drawing on page 21)
The clutch (N) provides a link between the gypsy and the main shaft (A). The clutch can be released (disengagement) by using the handle (1) which, when inserted into the  gypsy cover (N), must be turned counter-clockwise. The clutch will be re-engaged by turning it clockwise.
MOD. 500/1200 (see drawings on pages 22 and 24)
The clutch (3) provides a link between the gypsy and the main shaft (mod.500 = 19 – mod.1200 = 21 or 23). The clutch can be released (disengagement) by using the handle  (1) which, when inserted in the bush (8) of the drum or into the gypsy cover (2), must be turned counter-clockwise. The clutch will be re-engaged by turning it clockwise.

WEIGHING THE ANCHOR
Turn on the engine. Make sure the clutch is engaged and remove the handle. Press the UP button on the control provided. If the windlass stops and the hydraulic magnetic switch (or thermal cutout) has not tripped, wait a few seconds and try again (avoid keeping the button pressed). If the hydraulic magnetic switch, has tripped, reset it and wait a few minutes before weighing anchor once again. If, after a number of attempts, the windlass is still blocked, we suggest to move the boat to release the anchor. Check the upward movement of the chain for the last few meters in order to avoid damages to the bow.

CASTING THE ANCHOR
The anchor can be cast by using the electrical control or manually. To operate manually, the clutch must be disengaged allowing the gypsy to revolve and letting the rope or chain fall into the water. To slow down the chain, the handle must be turned clockwise. To cast the anchor by using the electrical power, press the DOWN button on the control provided. In this manner, anchor casting is under control and the chain and rope unwind evenly. In order to avoid any stress on the windlass -once the boat is anchored- fasten the chain or secure it in place with a rope.
DRUM USE MOD. 1200 D (see drawing on page 24)

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: before carrying out warping operations, check that the anchor and relative rope or chain are solidly fixed to a bitt or another strong point on the boat.
For the independent use of the drum (9) release the clutch with the handle (1), (at least 2 turns of the bush anticlockwise). Remove the handle from the bush (8) on the gypsy, wrap the rope around the drum (at least 3 turns). Activate the windlass control, keeping the rope under tension during take up. By varying the tension during take up it is possible to modify the rope winding speed.

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: during take up maintain a safe distance between hands and windlass drum.
Once take up is complete, screw up the clutch by tightening the drum bush clockwise and secure the rope to a bitt or other strong point on the boat.

MAINTENANCE

Quick GP2 500 GP2 500 Windlass - fig 4

POS.  DESCRIPTION
1 Straight windlass lever – nylon
2 Gypsy cover
3 Windlass clutch cone
4A Gypsy 6 mm
4B Gypsy 7 mm – 1/4”
4C Gypsy 8 mm
4D Gypsy 5/16”
5 Screw
6 Grower
7 Rope/chain stripper
8 Oil seal
9 Screw
10 Screw
11 White plastic 150 windlass cover
12 Screw for  pressure lever
13 Spring for pressure lever
14 Pressure lever
15 Sensor
16 Gasket watertight
17 Bearing
18 Output gear
19 Shaft series
20 Plug
21 Circlip
22 Bearing
23 Gear
24 Gear
25 Plug
26 White plastic 150 windlass base
27 Screw
28 Screw
29 Motor
30 Screw
31 Mooring rope puller pin
32 Plug
33 Washer
34 Roller bearing cage
35 Gear wheel
36 Gear motor shaft
37 Gasket/jig
38 Studs
39 Washer
40 Spring washer
41 Nut
42 Hexagonal cheese-headed screw
43 Spacer
44 O-ring

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: make sure the electrical power to the motor is switched off when working manually on the windlass.
Carefully remove the chain from the gypsy.
Quick ® windlasses are manufactured with materials resistant to marine environments. In any case, any salt deposits on the outside must be removed periodically to avoid corrosion and damage to the equipment.
The parts where salt may have built up should be washed thoroughly with fresh water. Once a year, the drum and the gypsy are to be taken apart as follows:

MOD. 500
Use the handle (1) to remove the gypsy cover (2); remove the top clutch cone (3); loosen the fixing screws (5) of the chain stripper (7) and remove it and pull off the gypsy (4).
Clean all the parts removed to avoid corrosion, and grease the shaft thread (19) and the gypsy (4) where the clutch cones (3) rest (use grease suitable for marine environment).
Remove any oxide deposits from the terminals of the electric motor and the reversing contactor unit; grease them.

MAINTENANCE

Quick GP2 500 GP2 500 Windlass - fig 5

POS.  DESCRIPTION
1 Windlass lever – Nylon
2 Gypsy cove
3 Windlass clutch cone
4A Gypsy 6 mm
4B Gypsy 7 mm – 1/4”
4C Gypsy 8 mm
4D Gypsy 5/16”
5 Screw
6 Grower
7 Rope/chain stripper
8 Bush
9 Drum
10 Oil seal
11 Screw
12 Screw
13 Anodized windlass cover
14 Screw for  pressure lever
15 Spring for pressure lever
16 Pressure lever
17 Sensor
18 Gasket watertight
19 Bearing
20 Output gear
21 Shaft series
22 Plug
23 Long shaft series
24 Key
25 Circlip
26 Bearing
27 Gear
28 Gear
29 Anodized windlass base
30 Screw
31 Motor
32 Screw
33 Plug
34 Plug
35 Washer
36 Roller bearing cage
37 Gear wheel
38 Gear motor shaft
39 Gasket/jig
40 Studs
41 Washer
42 Spring washer
43 Nut
44 Spacer
45 O-ring

Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon WARNING: make sure the electrical power to the motor is switched off when working manually on the windlass.
Carefully remove the chain from the gypsy.
Quick ® windlasses are manufactured with materials resistant to marine environments. In any case, any salt deposits on the outside must be removed periodically to avoid corrosion and damage to the equipment. The parts where salt may have built up should be washed thoroughly with fresh water.
Once a year, the drum and the gypsy are to be taken apart as follows:

MOD. FF
VERSION WITH FREEFALL SYSTEM
(see drawing on page 21)
Use the handle (1) to unscrew the gypsy cover (N); loosen screw (H) and take off the gypsy cover.
Loosen the screws (5) of the chain stripper (7) and remove it; remove the gypsy (4).

MOD. 1200
NO-DRUM VERSION
Use the handle (1) to remove the gypsy cover (2); remove the top clutch cone (3); loosen the fixing screws (5) of the chain stripper (7) and remove it and pull off the gypsy (4).

MOD. 1200 D
DRUM VERSION
Use the handle (1) to loosen the bush (8); pull off the drum (9) and the top clutch cone (3); loosen the fixing screws (5) of the rope/chain stripper (7) and remove it. Pull off the gypsy (4).

MOD. FF – MOD. 1200 – MOD. 1200 D
Clean all the parts removed to avoid corrosion, and grease the shaft thread (21, 23 or A) and the gypsy (4) where the clutch cones rest (use grease suitable for marine  environment) (3).
Remove any oxide deposits from the terminals of the electric motor and the reversing contactor unit; grease them.

USAGE GP2 FREE FALL

FREEFALL SYSTEM MOD. GP2 1200 FF
Goodman MSH093E21AXAA Split Type Room Air Conditioner - Warning Icon ATTENTION: The automatic system should be activated or deactivated with the clutch closed (engaged) to avoid damage to the electromechanical components.

ACTIVATING THE FREEFALL SYSTEM
Follow the directions given below to activate the freefall system:

  • Turn the cover F until the pin’s hole D faces upwards (as shown in fig.A).
  • Shut off power to the windlass.
  • Block the chain with a lock.
  • Pull the knob G until the pin is completely out D .
  • Make certain the clutch is closed (engaged).
  • Release the chain.
  • Turn power to the windlass back on.

Quick GP2 500 GP2 500 Windlass - fig 6

Hold down the DOWN button to open the clutch (disengaged).
As a result the gypsy will turn freely around its axis.
On the other hand, hold down the UP button to close the clutch (engaged). As a result, the gypsy is integral to the “A” axis again.

CASTING WITH THE FREEFALL SYSTEM
With the freefall system activated, keep the DOWN button pressed up to the point in which the anchor can fall freely without encountering any problems and then release the button.
To slow down or stop letting the chain fall down, hold down the UP button until the desired effect is obtained.

WEIGHING THE ANCHOR WITH THE FREEFALL SYSTEM
Perform the procedure given in paragraph USAGE – WEIGHING THE ANCHOR.

DEACTIVATING THE FREEFALL SYSTEM
Follow the directions given below to deactivate the freefall system:

  • Turn the cover F until the pin’s hole D faces upwards.
  • Shut off power to the windlass.
  • Block the chain with a lock.
  • Push the pin D , into the center of the gypsy with the aid of a suitable tool, as shown in fig.B.
  • Make certain the clutch is closed (engaged).
  • Release the chain.
  • Turn power to the windlass back on.

Quick GP2 500 GP2 500 Windlass - fig 7

When the freefall system is deactivated, the chain can be lowered only electrically or manually (see paragraph USAGE – CLUTCH USE).

MAINTENANCE

Quick GP2 500 GP2 500 Windlass - fig 8

POS.  DESCRIPTION
A Shaft
B Windlass pin guide
C Screw
D Pin
E Spring pin
F Gypsy cover
G knob
H Gypsy cover screw
I screw
L Pin
M Spring pin
N Pilot boss

SET

Quick GP2 500 GP2 500 Windlass - fig 9 OSP GYPSY GP2  500/1200 5/16”
OSP GYPSY GP2 500/1200 6MM
OSP GYPSY GP2 500/1200 7MM-1/4”
OSP GYPSY GP2 500/1200 8MM
OSP GYPSY GP2 500/1200 ROPE
FVSSB070516MA00
FVSSB0706G0MA00
FVSSB070714MA00
FVSSB0708G0MA00
FVSSB07CMG00A00
Quick GP2 500 GP2 500 Windlass - fig 10 OSP KIT GP2 500/1200 PRESSURE LEVER FVSSTCMG0000A00
Quick GP2 500 GP2 500 Windlass - fig 11 OSP GYPSY COVER “SERIES 2” FVSSCPBBASG0A00
Quick GP2 500 GP2 500 Windlass - fig 12 OSP WINDLASS DRUM  “SERIES 2” STAINLESS S. FVSSMSE0800XA00
Quick GP2 500 GP2 500 Windlass - fig 13 OSP DRUM BUSH “SERIES 1-2” FVSSGMSDCP05000
Quick GP2 500 GP2 500 Windlass - fig 14 OSP KIT GP2 WINDLASS CLUTCH CONE FVSSCFG00000A00
Quick GP2 500 GP2 500 Windlass - fig 15 OSP COMPLET FF “GP2” GYPSY COVER FVSSCPBBGFF0A00
Quick GP2 500 GP2 500 Windlass - fig 16 OSP KIT GP2 500/1200 FF WINDLASS PIN GUIDE FVSSGPGFFS00A00
Quick GP2 500 GP2 500 Windlass - fig 17 OSP STRAIGHT WINDLASS LEVER – NYLON FVSSLVSDN000A00

Quick logoQUICK® S.P.A. – Via Piangipane, 120/A – 48124 Piangipane (RAVENNA) – ITALY
Tel. +39.0544.415061 – Fax +39.0544.415047
www.quickitaly.comE-mail: quick@quickitaly.com

Documents / Resources

Quick GP2 500 GP2 500 Windlass [pdf] User Manual
GP2 500 GP2 500 Windlass, GP2 500, GP2 500 Windlass, Windlass

References

Leave a comment

Your email address will not be published. Required fields are marked *