NOVUS logoNOVUS NV-2ATM-6701 Special Purpose IP Camera Quick start guide
NV-2ATM-6701/F

CAUTIONS AND WARNINGS

THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
CE SYMBOL DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79–106, with changes).
SONY MDR-RF855RK Wireless Stereo Headphone System - warning DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE) (OJ L 197, 24.7.2012, p. 38–71, with changes).
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88–110, with changes).
COMMISION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending Annex II to Directive 2011/65/EU of the European Parliament and of the Council as regards the list of restricted substances.
DIRECTIVE (EU) 2017/2102 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Exclusion of liability in the event of damage to data contained on disks or other devices or media:
The manufacturer is not liable in the event of damage or loss of data contained on disks or other devices or carriers during the operation of the Product.
Obligation to consult the Manufacturer before performing any action not provided for in the instruction manual or other documents:
Before performing an action that is not provided for a given Product in the user manual, other documents attached to the Product or does not result from the normal purpose of the Product, it is necessary, under pain of exclusion of the Manufacturer’s liability for the consequences of such action, to contact the Manufacturer.
Pictures in this publication showing camera views can be simulations. Actual camera images may vary depending on the type, model, settings, observation area, or environmental conditions.

SAFETY REQUIREMENTS

Warning icon Before using the device, read the instruction manual in order to ensure proper and safe operation of the device. Failure to comply with the instructions may lead to damage to the device and/or safety violations.
Warning icon The user may not repair the device himself. Repairs and maintenance of the device may only be performed by qualified service personnel.
Warning icon The device, which is an element of a professional CCTV system used for supervision and control, is not intended for self-assembly in households by persons without specialist knowledge.

  1. Please read this manual carefully before installation and operation;
  2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary;
  3. It is necessary to comply with the safety requirements described in the manual, as they have a direct impact on the safety of users and the durability and reliability of the device;
  4. All activities performed by installers and users must be carried out as described in the manual;
  5. The device should be disconnected from power sources during maintenance procedures;
  6. It is not allowed to use any additional devices, components or accessories not provided for and not recommended by the manufacturer;
  7. Do not install this device in places where proper ventilation cannot be provided (e.g. closed cabinets, etc.), as this may cause heat build-up and may result in damage;
  8. Do not place the device on unstable surfaces. Installation must be carried out by qualified personnel with appropriate permissions in accordance with the recommendations provided in this manual;
  9. The device may be powered only from sources with parameters compliant with those indicated by the manufacturer in the technical data;

NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 1 As the product is constantly improved and optimised, some of its parameters and functions may have changed from those described in this manual. If in doubt, please refer to the user manual at www.novuscctv.com
The user manual located at www.novuscctv.com is always the most up-to-date version.

FOREWORD INFORMATION

1.1. General Characteristics

  • Miniature camera size 30mm x 30mm x 30mm
  • Sensor resolution: 2 megapixels
  • Illumination from 0.05lx
  • Electronic Shutter from 1/25 s to 1/100 000 s.
  • Wide Dynamic Range (WDR)
  • Digital Noise Reduction (DNR)
  • Defog function (F-DNR)
  • Highlight Compensation (HLC)
  •  Back Light Compensation (BLC)
  • Reduction of image flicker (Antiflicker)
  • Lens type fixed focal pinhole, f = 2.8mm/F2.2
  •  Built-in webserver: camera configuration through the website
  • Video compression: H.264, H.264+, H.265, H.265+, MJPEG / G711
  • Max. video resolution up to 1920 x 1080
  • Multi streaming: compression, resolution, speed and quality defined individually for each video stream
  • ROI functions
  • Motion detection
  • Privacy Zones
  • RTSP protocol support for video transmission
  • Schedule
  • Micro SD card up to 256GB
  • Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server, saving file on microSD card
  • Supports up to 3 streams
  • ONVIF Protocol Support
  • Software: NMS (NOVUS MANAGEMENT SYSTEM) for video recording, live monitoring, playback and remote IP devices administration
  • Intelligent image analysis functions: tamper, abandoned object, object disappearance, line cross, zone entrance, zone exit, face detection, cross counting, heat map, scene change, video blurred, video color cast, objects distinguishing, intrusion detection, target counting by area
  • Power supply: 12 VDC / PoE (IEEE 802.3af, Class 3)

FOREWORD INFORMATION

1.2. Technical specification 

IMAGE
Image Sensor 2 MPX CMOS sensor 1/2.8” SONY
Number of Effective Pixels 1945 (H) x 1097 (V)
Min. Illumination 0.05 lx/F2.2 – color mode
Electronic Shutter auto/manual: 1/25 s ~ 1/50000 s
Wide Dynamic Range (WDR) yes
Digital Noise Reduction (DNR) 2D, 3D
Defog Function (F-DNR) yes
Highlight Compensation (HLC) yes
Back Light Compensation (BLC) yes
Reduction of image flicker (Antiflicker) yes
LENS
Lens Type pinhole, f=2.8 mm/F2.2
DAY/NIGHT
Switching Mode auto, manual
Switching Level Adjustment yes
Switching Delay 2 ~ 60 s
NETWORK
Stream Resolution 1920 x 1080 (Full HD), 1280 x 720 (HD), 704 x 576, 640 x 480 (VGA), 640 x 360, 480 x 240, 352 x 288 (CIF)
Frame Rate 30 fps for each resolution
Multistreaming Mode 3 streams
Video/Audio Compression H.264, H.264+, H.265, H.265+, MJPEG/G.711
Number of Simultaneous Connections max. 8
Bandwidth 16 Mb/s in total
Network Protocols Support HTTP, TCP/IP, IPv4, IPv4/v6, UDP, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP, UPnP, SNMP, QoS, IEEE 802.1X, PPPoE, SMTP, SSL/TLS, HTML5, RTMP
Camera Configuration from Internet Explorer, Firefox, Chrome, Opera, Safari, Edge browser
languages: Polish, English, and others
Compatible Software NOVUS MANAGEMENT SYSTEM VSS, NOVUS MANAGEMENT SYSTEM AC, N Control 6000
Mobile applications N-VID6 (iPhone, Android)
OTHER FUNCTIONS
Privacy Zones 4 video mask type: single color
Motion Detection yes
Region of interest (ROI) 8
Video Content Analysis (VCA) tamper, abandoned object, object disappearance, line cross, zone entrance, zone exit, face detection, cross counting, heat map, Scene Change, Video Blurred, Video Color Cast, objects distinguishing, intrusion detection, target counting by area
Image Processing corridor mode, vertical flip, horizontal flip
System Reaction to Alarm Events e-mail with attachment, saving file on FTP server, saving file on SD card, alarm output activation
Restoring default settings via web browser, using reset button, via NMS IPTool software
INTERFACES
Video Output BNC, 1.0 Vp-p, 75 Ohm
Audio Input/Output 1 x Jack (3.5 mm)/1 x Jack (3.5 mm)
Alarm Input/Output 8 (NO/NC)/4 relay type (max. 12VDC/300mA)
Network Interface 1 x Ethernet – RJ-45 interface, 10/100 Mbit/s
Memory Card Slot microSD – capacity up to 256GB
INSTALLATION PARAMETERS
Dimensions (mm) 88 (W) x 25 (H) x 108 (L) – main module
30 (W) x 30 (H) x 30 (L) – sensor module
Weight 0.35 kg
Power Supply 12 VDC, PoE (IEEE 802.3af, Class 3)
Surge protection TVS 4000 V
Power Consumption 6 W
Operating Temperature -30°C ~ +60°C
Humidity max. 95%, relative (non-condensing)

1.3. Camera module and main module dimensions (mm)

NOVUS NV-2ATM-6701 Special Purpose IP Camera - dimensions

1.4. Package contents
After opening the package make sure that the following elements are inside:

  • Main module and camera module (both modules taken as a whole, hereafter referred to as “IP camera”)
  • Quick start guide
  • Screws, dowels and mounting template
  • Wall mounting bracket

If any of this elements has been damaged during transport, pack all the elements back into the original box and contact your supplier for further assistance.
The power supply and BNC-BNC coaxial cable are not included in the camera equipment, so the user is obliged to provide it himself. A suitable power supply should meet the conditions described in section 2.2 Power supply connection on the next page.

START-UP AND INITIAL IP CAMERA CONFIGURATION

CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches the temperature of location it is currently in. Turning the device on immediately after bringing it from a location with lower ambient temperature is forbidden, as the  condensing water vapour may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular inputs, outputs and adjusting elements that the device is equipped with.

2.1 Description of connectors and camera equipment of both camera modules

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Description of connectors

2.2. Power supply connection
The main module of the camera can be powered from a commercially available DC power supply, provided that it meets the technical requirements of the camera i.e. the source must provide 12VDC voltage, must allow the consumption of at least 10W of power, and have a barrel DC 2.1/5.5 plug with the correct polarity of the contacts:

NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 2

It is also possible to power the camera via the RJ45 network socket, using PoE technology (IEEE 802.3af, Class 3).
Power is required for both the main module and the camera itself. The camera can be powered from a 12VDC power supply allowing at least 10W power consumption, or from the output marked on the main module of the camera as “Power OUT”, using a two- wire cable terminated with a DC 2.5/5.5 cylindrical plug with contact polarity as above. This cable must be equipped on its own and is not included in the kit.
Caution!
Do not use power supplies and POE adapters that do not comply with the IEEE 802.3at standard, the so-called “passive POE” power supplies. Damage resulting from the use of an unsuitable adapter is not covered by the warranty!

2.3. Camera module mounting

  1. Remove the camera module holder by unscrewing both fixing screws on the sides indicated by red arrows.
  2. Mount the camera module holder in the selected place with a suitable screw or bolt.
  3. Place the camera module between the fork of the holder and mount it with fixing screws, screwing them in so that you can adjust it.
  4. Adjust the camera module position and tighten with the fixing screws.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Description of connectors 1

2.4. Installation of the main camera module

  • Using the mounting template, mark the points for future mounting holes. (1)
  • Drill holes, insert pins (2) into them and screw the bracket part as shown in the picture (3)
  • Screw the second part of the bracket to the main module. (4)
  • Slide from the top part of the bracket together with the module into the bracket attached to the wall. Clicking indicates that the camera module has been installed correctly. (5)

NOVUS NV-2ATM-6701 Special Purpose IP Camera - main camera module

2.5 Connection of alarm inputs and outputs

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Connection of alarm inputs and outputs

2.6. Starting the IP camera
To run NOVUS IP camera you have to connect ethernet cable between camera and switch or computer.
You can power it from 12VDC power supply compatible with camera power supply specification.
The recommended way to start an IP camera and perform its configuration is a direct connection to the network switch which is not connected to other devices. To obtain further information about network configuration parameters (IP address, gateway, network mask, etc.) please contact your network administrator.

  • Connection using external power supply and network switch

NOVUS NV-2ATM-6701 Special Purpose IP Camera - power supply

  • Connection using external power supply directly to the computer

NOVUS NV-2ATM-6701 Special Purpose IP Camera - power supply 1

  • Connection using network switch with PoE

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Connection using network switch

Information:
Power supply adapter is not included. Please use power adapter with parameters specified in user ‘s manual.

2.7. Initial configuration via the web browser
The default network settings for camera are :

  1. IP address – 192.168.1.200
  2. Network mask – 255.255.255.0
  3. Gateway – 192.168.1.1
  4. User name – root
  5. Password – pass

Knowing the camera’s IP address you need to appropriately set PC IP address, so the two devices can operate in one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera ranges from 192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for camera and PC computer.
You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera yourself or select DHCP mode (DHCP server is required in this method in target network) by using web browser or by NMS software. When you use DHCP server check IP address lease and its linking with camera MAC address to avoid changing or losing IP address during device operation or network/ DHCP server breakdown. You have to remember to use a new camera IP address after changing network parameters.
After network setting configuration has been done, the camera can be connected to a target network.

2.8. Security recommendations for network architecture and configuration
CAUTION!
Below are shown security recommendations for network architecture and configuration of CCTV systems that are connected to the Internet to reduce the risk of unauthorized interference with the system by a third party.

  1. Absolutely change the default passwords and user names (if the device gives this possibility) of all applied network devices (recorders, cameras, routers, network switches, etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special characters if there is such possibility.
  2. Depending on the available functionality in the order to restrict access to the used network devices at the administrator account level, it is recommended to configure the users accounts accordingly.
  3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the access to recorder system from the Internet on all ports, which gives possibility for an unauthorized interference with the system.
    Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance of the connection (detailed information about ports of communication in different models of recorders, cameras, etc. can be found in the operating instructions).
  4. Use routers with firewall function and make sure it is enabled and properly configured.
  5. It is recommended to change the default network communication port numbers of used devices if there is such possibility.
  6. If used network devices has a UPnP feature and it is not used, turn it off.
  7. If used network devices has a P2P feature and it is not used, turn it off.
  8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
  9. If used network devices support IP filtering for authorized connections function, it is recommended to use it.
  10. If used recorder has two network interfaces it is recommended to use both of them to physically separate network for cameras and network for Internet connection. The only device in the system, accessible from Internet will be recorder – there will be no physically access directly to any camera.

NETWORK CONNECTION USING WEB BROWSER

3.1. Recommended PC specification for web browser connections
Requirements below apply to connection with an IP camera, assuming smooth image display in 1920 x 1080 resolution and 30 fps speed.

  1. CPU Intel i7 3 GHz
  2. RAM Memory min. 6 GB
  3. VGA card Nvidia GeForce 1GB
  4. Operating System Windows 10
  5. Network card 100/1000 Mb/s

3.2. Connection with IP camera via web browser

  • Connecting to the camera for the first time

Enter the IP address of the camera (default 192.168.1.200) in the address bar of the web browser. If the address is correct and the target device is currently available, the first connection window will be displayed. In this window, user should read the privacy  statement and after reading it, select the checkbox next to the Already Read button, and press this button.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser

The acceptance of the privacy statement cannot be omitted. This window only appears the first time you log in, but it can be displayed again at any time.
Access to the privacy statement can be found in the menu Config > System > Basic information > Privacy statement.

  • Device Activation

After accept privacy statement, device activate window appears. In this window user has to set a password for the web account.
Check the “Activate Onvif user” checkbox to change the password for the Onvif account to the same password as for the web account.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 1

NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 1 If the user assigns a new password during the device activation but does not check the “Activate Onvif User” checkbox, the Onvif account will remain with the default login data (login: root and password: pass).

The password can be up to 16 characters long. While password is entered strength of it displaing on an ongoing basis by the security level indicator. To ensure the good security of the password, use upper and lower case letters, numbers and special characters. After entering the correct password twice and confirming it with the OK button, the administrator password will be saved, the window will close and the login screen will be displayed.

  • User accounts

The Web account is the administrator account created during the activation of the device. It means that the user logging in, by using the root login and a predefined password and have access to the full functionality and all available settings in the camera. The account is also used to log in to the camera via the 6000 series network recorders and NOVUS MANAGEMENT SYSTEM VSS and NOVUS MANAGEMENT SYSTEM AC (software using the LongPolling event method).
The Onvif account is an account used to log in to the camera via the NOVUS MANAGEMENT SYSTEM VSS and NOVUS MANAGEMENT SYSTEM AC software or using the Onvif or the RTSP protocol. This account is created automatically during activation of the device, and the default login data are login: “root” and password: “pass”.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 1 For security reasons, immediately change the default password for the Onvif account after activating the device. It is recommended to set the same password in both accounts: the Onvif account and the web account.

  • Onvif account edition

In order to change the Onvif account password, after logging in, go to the Settings tab in the upper right corner and then Network > Onvif.
In the Onvif tab, click the Modify button, then in the Edit User window, enter the new password and confirm with OK button. If the connection to the camera via the NOVUS MANAGEMENT SYSTEM software is using the LongPolling event handling method, the same password for the Onvif account as for the Web account must be set in this step.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 2

In order to delete the Onvif account, select the user by clicking on the appropriate row in the table, then click Delete button. Please note that deleting Onvif account means that the camera cannot be added to NOVUS MANAGEMENT SYSTEM software. Add button is used to create new Onvif account.

  • Logging in to the camera for the first time

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 3

In this window, in order to login to camera, enter the user name root and the newly set administrator password. In the Stream type field user can select the stream that is displayed in the live view window after login. The Language field allows to change the  interface language. The Forget Password option allows to log in to the camera if you forget the administrator password and for this is required to know the answers to the security questions (set in the next step).
After entering appropriate data, click the Login button to login to the web panel of the camera.

  • Safety questions

The next step in logging in for the first time is entering answers to the security questions. In the window that appears, select questions from among those available on the list and enter your own answers.
Knowing the right answers is essential to recovering the administrator password.
NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 4NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 1 This step cannot be omitted. The security question window is displayed only during the first login, and the only possibility to change the given answers is to restore the factory settings and go through all stages of the first connection with the camera.

  • Plug-in installation

If the browser has no connected to any of the 6000 series cameras so far, or if an older version of the plug-in is installed, a message will be displayed in the remote viewing window that the appropriate plug-in version must be installed.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 5

NOVUS NV-2ATM-6701 Special Purpose IP Camera - web browser 6

To start plug-in installation, click Here button. Then the browser displays a window asking how to proceed with the NetAIIPCamera.exe file. Press the Run button to start the plug-in installer.
In the installer window, select the installation language (English by default) and then click Install button to install plug-in. After installation click the Finish button to close the installer and refresh the browser window (you can also close and restart the browser).
If after installation and browser window refresh, the same text appears on the screen, go to the browser Tools (the gearwheel icon in the top right corner), then click Menage add-ones. In the window that appears click right mouse button on the NetAIIPCamera Control, then click the Enable option and refresh the browser window.
After completion all of the above steps, preview of the camera in the live view window should appears.

WWW INTERFACE – WORKING WITH IP CAMERA

4.1 Displaying live video 

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Displaying live video

  1. Camera menu:
    • Live – opens the camera live video,
    • Config – opens the camera configuration menu,
    • Search – opens the camera playback,
    • Statistics – opens window with counting statistics and heat map
  2. The buttons for changing the displayed stream and fluency:
    • Allow to change the displayed stream to Main stream, Sub stream.
    • Allow you to choose between Real-time, Balanced and Fluent fluency.
  3. Alarm icons – icons showing the current status of some camera alarms.
  4. Live video window
  5. Image settings buttons – these buttons change the picture display mode in the live video preview
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 3 Original size
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 4 Proper size
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 5 Adapt
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 6 Full screen

ELECTRIC CONNECTORS AND ACCESORIES 

6. Function buttons:

NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 7 Start/stop live view
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 8 Snapshot
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 9 Zoom In (digital)
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 10 Enable/disable graphical representation of image analysis
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 11 Activation of the alarm output
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 12 Enable/disable audio
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 13 Start Recording
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 14 Zoom out (digital
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 15 Camera menu control
NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 19 Enable face recognition panel

MICRO SD CARD INSTALLATION

Camera supports microSD cards up to a maximum size of 256 GB. In order to install the card Turn off the camera power.

  • Turn off the camera.
  • Mount microSD card in the socket indicated by the arrow
  • Turn on the camera.
  • Check the microSD card by checking its capacity in the “System” -> “SD Card” tab.

NOVUS NV-2ATM-6701 Special Purpose IP Camera - MICRO SD CARD INSTALLATION

FACTORY SETTINGS RESTORING

Restoring factory settings of the IP camera restores all default settings. This process takes about two minutes. NOVUS cameras allow to restore defaults via:

  • software (via NMS IPTool)
  • software (via web browser )
  • hardware (using reset button (RST))

6.1. Software factory settings restoring via NMS IPTool
NMS IPTool (version 3.5 or later) allows to restore factory settings. To restore settings via NMS IPTool, find the camera in the list of available devices and then, on the right side of the row click NOVUS NV-2ATM-6701 Special Purpose IP Camera - icon 20, then within 30 seconds disconnect power of the camera. After reconnecting the camera, all settings are factory default.

6.2. Software factory settings restoring via web browser
Restoring factory settings via web browser allows you to optionally keep some settings, such as network settings. To restore default settings go to: “Maintenance -> Backup and Restore” tab.
6.3. Hardware factory settings restoring
In order to restore factory settings using reset button (RST) press the reset button and hold on for 10 seconds, then release button and log on after 2 minutes using default IP address (http://192.168.1.200) and default user name (root) and password (pass).

NOVUS NV-2ATM-6701 Special Purpose IP Camera - Hardware factory settings restoring

NOVUS logo

AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 0 546, kontakt@aat.pl
www.novuscctv.com

Documents / Resources

NOVUS NV-2ATM-6701 Special Purpose IP Camera [pdf] User Guide
NV-2ATM-6701-F, NV-2ATM-6701-F, NV-2ATM-6701 Special Purpose IP Camera, NV-2ATM-6701, Special Purpose IP Camera, Purpose IP Camera, IP Camera

References

Leave a comment

Your email address will not be published. Required fields are marked *