LEDALITE logoCantilever Jump
Installation Instructions
ID-1231_Jump_Cantilever
Standalone or continuous
run configurations

System Overview

These instructions review how to install Jump wall fixtures. Jump 4ft and 8ft modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphic below showsthe components required to install a typical run of Jump wall fixtures.
IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installationLEDALITE ID-1231 Jump Cantilever - fig

Module Lengths

Jump cantilever systems come in 4ft and 8ft modules. Overall module lengths are shown below.
Module lengths do not include endcaps.LEDALITE ID-1231 Jump Cantilever - Module LengthsEndcaps
Add two endcaps to the length of each run.LEDALITE ID-1231 Jump Cantilever - Module Lengths 1

Mount Spacing

LEDALITE ID-1231 Jump Cantilever - Mount SpacingRun Configurations
The tables below indicate how 4ft and 8ft modules can be combined to create continuous runs of various lengths.

Nominal Row Length Number of Modules Required Installed Row Length (not including end caps)
4′ 8′
4′ 1x 4′ – 3/16
8′ 1x 8′ – 3/8″
12′ 1x 1x 12′ – 9/16″
16′ 2x 16′ – 3/4
20′ 1x 2x 20 – 15/16
24′ 3x 24 1 – 1/16
28′ 1x 3x 28 1 – 1/4
32′ 4x 32 1 – 7/16
36′ 1x 4x 36 1 – 5/8
40′ 5x 40 1 – 13/16
44′ 1x 5x 44 1
Nominal Row Length Number of Modules Required Installed Row Length (not including end caps)
4′ 8′
52′ 1x 6x 52 2 – 3/8
56′ 7x 56 2 – 9/16
60′ 1x 7x 60 2 – 11/16
64′ 8x 64 2 – 7/8
68′ 1x 8x 68 3 – 1/16
72′ 9x 72 3 – 1/4
76′ 1x 9x 76 3 – 7/16
80′ 10x 80 3 – 5/8
84′ 1x 10x 84 3 – 13/16
88′ 11x 88 3
92′ 1x 11x 92 4 – 3/16
96′ 12x 96 4 – 3/8
100’ 1x 12x 100 4 – 1/2

*Overall run lengths provided do not include endcaps. Add two endcaps to the overall length of each run.

  1. Prepare Fixtures
    Arrange boxed fixtures on floor in specified mounting locations; remove fixtures from boxes.
  2. Attach Brackets to Wall
    LEDALITE ID-1231 Jump Cantilever - Mount Spacing 1LEDALITE ID-1231 Jump Cantilever - Mount Spacing 2Attach brackets to wall using appropriate hardware (1/4 fastener recommended). Ensure structure can support the weight of the fixture at 3.5lbs/ft. Install using two center holes for non-power locations and use 4 outer holes for power locations. Power locations require a vertically oriented 2 x4 recessed utility box (supplied by others).
    Use a spirit level and adjust mounting screws to level brackets.
    Level the bracket by loosening or tightening the top screw or screws that hold the bracket to the structure.
  3. Complete Electrical Connection in WallLEDALITE ID-1231 Jump Cantilever - Mount Spacing 3(Power locations only) Feed power cable through ½“ hole in mounting bracket. Complete electrical connection to junction box through square cut out in mounting bracket. Use supplied cable clips to secure the power cable to the interior of the mounting
    channel at 4 increments.
  4. Slide on Wall CoversLEDALITE ID-1231 Jump Cantilever - Wall CoversSlide on Wall covers and use supplied #8 lock-nut to secure to cantilever arm bracket, (non-power mount shown).
  5. Attach Fixture HangingBracketsLEDALITE ID-1231 Jump Cantilever - Brackets
  6. On the floor, slide power plates into fixture ends.
    Attach supplied bushings in power locations and plugs in non-power locations.LEDALITE ID-1231 Jump Cantilever - Brackets 1
  7. Install Mounting BracketLEDALITE ID-1231 Jump Cantilever - Mounting Bracket
  8. Attach the Fixture to the BracketLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 1Raise fixture to brackets and use the supplied countersunk screw with countersunk washer to attach the fixture to the bracket. Adjust fixture hanging brackets so fixture is flush with cantilever arm and tighten.
  9. Run and Secure Power CablesLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 2Run power cable in fixture channel and through power plate at the end of the fixture. Secure power cable into fixture channel using supplied cable clips at 4 increments.
    Complete power connections using cut out in end of fixture.
  10. Attach Joiner Aligner BracketsLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 3On the floor, slide variable mount bracket into next fixture in run. Attach joiner-aligner brackets into opposite side.
  11. Suspend and Join Additional Fixtures in RowLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 4
  12. Complete power connections between fixtures.LEDALITE ID-1231 Jump Cantilever - Mounting Bracket 5Join fixtures using supplied #8 screws and lock-nuts.
    Repeat steps 8-12 for each fixture in run.
  13. FinishingLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 6
  14. Attach End CapLEDALITE ID-1231 Jump Cantilever - Mounting Bracket 7Snap gasket to the end of the fixture and attach end caps using supplied #8 screws.
  15. Install lenses as shown.LEDALITE ID-1231 Jump Cantilever - Mounting Bracket 8

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuantto part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Sensor in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wi res MUST be connected between fi xtures.
    Note :
    – A maximum of 8 dr  vers can be wired to 8 sensors; confirm fixture driver count with factory.LEDALITE ID-1231 Jump Cantilever - Sensor in RowsMultiple Sensors Controlling Separates Zones in a Row
  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes :
    – A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count  with factory.
    – On ly one sensor is allowed on a wired zone. (Sensors can be paired together wire lessly via a mobile app).LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 1Sensor Spacing
    – For correct operation, sensor should be placed a minimum distance of 8ft apart.
    – Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 2

Important Consideration When Using Sensor in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
    DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 3

Daylight Sensor

The tight sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window = 2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 4 LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 5
Height Minor movement Major movement
h X1 Y1 X2 Y2
2.4 m (7.9 ft) 1.9 m (6.2 ft) 2.9 m (9.5 ft) 2.9 m (9.5 ft) 4.3 m (14.1 ft)
3 m (9.8 ft) 2.4 m (7.9 ft) 3.6 m (11.8 ft) 3.6 m (11.8 ft) 5.4 m (17.7 ft)

The detection area for the movement sensor can be roughly divided into two parts;

  • Minor movements (person moving = 3ft/s or 0.9m/s).
  • Major movements (person moving = 3ft/s or 0.9m/s).

Photosensor spatial response

LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 6

LEDALITE ID-1231 Jump Cantilever - Sensor in Rows 8 ATTENTION: Install in accordance with national and local building and electrical codes.
© 2023 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner. Phone: 604.888.6811 Web: ledalite.com/products Revision D November 7, 2023
Signify North America Corporation. 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807. Telephone: 855-486-2216 Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3. Telephone: 800-668-9008