innovita-LOGO

innovita Primo Eco 6 ic D LPG Gas Water Heater

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-PRODUCT

Product Information

Specifications

  • Model: Primo Eco 6 ic D, Primo Eco 11 ic D, Primo Eco 14 ic D
  • Type: Instantaneous Gas Water Heater

FAQ

  • What should I do before connecting the water heater?
    • Before connecting the water heater, ensure that the display cables are connected.
  • What is included in the water heater package?
    • The package contains 2 knobs for the control panel and 1 water filter for the water valve pipe fitting.

With the intention of improving the quality of its products, Innovita reserves the right to update the technical characteristics and data in this document without notice.

Before Connecting The Water Heater

Before connecting the water heater, make sure the display cables are connected

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-1

The water heater package contains:

  • nr. 2. Two knobs to attach to the control panel after installation
  • nr. 1. Water filter to insert in the water valve pipe fitting.

SYMBOLS

  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2GENERAL HAZARD
    • Comply with the indications described in the text. If there is no compliance, risks to objects or persons may be generated with consequent slight/medium or serious damage/injury to objects or persons.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-3ELECTRIC HAZARDS
    • Comply with the indications described in the text.
    • The symbol identifies the presence of electric components and the risk of electric shock.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-4HOT SURFACES
    • Comply with the indications described in the text.
    • The symbol identifies the presence of very hot components with consequent burn hazards.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-5PROHIBITION
    • Comply with the indications described in the text. The symbol identifies actions that must not be performed.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-6READ THE INSTRUCTIONS
    • Read and understand the instructions before performing any operation. Comply with the indications described in the text.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-7EARTH CONNECTION
    • The symbol identifies obligation of connection to earth.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-8DISPOSAL OF THE APPLIANCE
    • The user must dispose of the appliance at the end of its lifespan in relevant collection centres.

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-9The device is well built in accordance with the current legislation.
The CE sign positioned on the product indicates that it conforms to the following European Directives and Regulation:

  • Regulation Gas Appliance (UE) 2016/426
  • European Standard: gas-fired instantaneous water heaters for the production of domestic hot water EN 26:2015
  • Directive 2009/125/EC Ecodesign requirements for energy-related products
  • Regulation (EU) 2017/1369 setting a framework for energy labelling, the energy label carries the information regarding the product’s energy efficiency characteristics. In this way the end consumer can identify and compare similar products and can make informed choices regarding high efficiency appliances
  • Delegated regulation (EU) no. 812/2013
  • Delegated regulation (EU) no. 814/2013

Product datasheet

Declared load profile

Indoor sound power level (dB(A)) Water heating energy efficiency class

Water heating energy efficiency class (%)

Annual fuel consumption (GJ)

Annual electric energy consumption (kWh)

Nitrogen oxide emissions G20 (mg/kWh)

XS 62 A+ 77

2

0

37

M 62 A 72

6

0

26

L 62 A 75

12

0

34

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-10 innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-11

General And Safety Recommendations

General And Safety Recommendations For The Fitter And User

  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Any contractual and non-contractual liability for injury/damages caused to people, animals or objects due to installation, adjustment and maintenance errors, improper use and non-compliance with laws in force and current national and local regulations.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2The installation and use instruction manual constitutes and integral and essential part of the product equipment: it must be kept during the period of use and read carefully, because it contains all the information and warnings that must be complied with during installation, use and maintenance. In the case of loss or damage, request a copy from the professionally qualified staff. If the appliance is transferred to another user, always ensure that the booklet accompanies the appliance.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2The appliance must be intended for the use envisioned by the manufacturer. All other use must be considered improper and therefore hazardous.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Installation of the appliance and any other assistance and maintenance must be performed by qualified staff in in compliance with national and local laws and regulations in force, only using original spare parts.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Failure to comply with the recommendations set out in this manual and the failure to of the fitters and user to implement the indications herein cannot constitute a subject of a warranty claim.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2This appliance is used to heat water to a temperature lower than boiling point; it must therefore be connected to a domestic hot water distribution network, compatible with its performance and power.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2The appliance is fitted with safety devices that shut down functioning if there are problems with the appliance or system.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2During the entire life span of the machine, these devices must not be decommissioned: in the case of repeated interventions, request the intervention of professionally qualified staff.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2If water escapes, close the water supply and promptly inform professionally qualified staff.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2In the case of breakdown and/or malfunctioning of the appliance, deactivate it, refraining from any attempt at repair or direct intervention.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Maintenance interventions on the appliance must be performed by qualified staff in compliance with the regulations in force. In order to maintain the safety, reliability and performance of the appliance, maintenance must be performed at least once a year.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2In the case of prolonged absence, close the gas supply. If a risk of freezing is envisioned, empty the water contained in the appliance.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-4Do not touch hot parts of the appliance, which can reach high temperatures, with risk of burns in the case of contact.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-4Water at temperatures exceeding 50°C can cause scalding. Always check the temperature of the water before all use.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-3Do not touch the appliance with wet or damp parts of the body or with bare feet. Do not pull the electric cables. If the appliance power supply cable is damaged, request intervention of professionally qualified staff.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-8When the product has reached the end of its serviceable life, it shall be disposed of in an environmentally friendly way and disposed of according to the regulations in force.
    Separate collection and recycling of the product avoid negative impact for environment and health, and allows recovery of materials, in order to obtain energy and resources saving.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2On detecting the smell of gas, never operate electric switches, the telephone or any other object that may cause sparks. Ventilate the room by opening doors and windows and close the main gas cock. Request the intervention of professionally qualified staff.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Parts of packaging (plastic bags, polystyrene etc.) must not be left within the reach of children, since they are a potential source of danger.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2Before installing the appliance it is good practice to check that the same has arrived integral. If this is not the case, contact the dealer from where the appliance was purchased.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-2The appliance can be used by children over 8 years old and by persons with reduced physical and sensory conditions or lack of experience and knowledge, as long as they are supervised or have been given instructions concerning safe use of the appliance and understanding of inherent hazards. Children must not play with the appliance. Cleaning and maintenance to be performed by the user must not be carried out by unsupervised children.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-23It is prohibited to block the intake or dissipation grilles or the ventilation opening of the room where the appliance is installed using rags, paper or other.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-23The user must not intervene on sealed components or tamper with the seals. Only authorised technicians can remove the seals from the sealed components.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-23Attempts at repairs are prohibited in the event of a fault and/or appliance malfunctioning.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-23Do not clean the appliance or parts of the same using easily inflammable substances.
  • innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-23Do not install above cooker-tops.

Instructions For Installation

Description of the appliance

NOx identifies the group of the two most important nitrogen oxides:

  • NO Nitrogen monoxide (not harmful to humans)
  • NO2 Nitrogen dioxide (very harmful to humans and the environment).

NOx is formed during combustion processes at high temperatures.
To reduce NOx emissions it is necessary to cool the flame.
The water inside the water heater, after have been heated by heat exchanger, gets in the burner, cools the flame and gets out to the final user.
The special burner cools the flame and check the airflow necessary for the combustion, set up “cooled flames” avoiding the loss of thermal efficiency, generating an optimal combustion with low emissions.

Regulations

  • The use of gas devices is controlled by precise regulations.
  • It is essential to observe regulations in force.
  • Installation of liquid petroleum gas (L.P.G) must comply with all the distributor’s requirements and those of the regulations.
Wall Mounting

WARNING

Do not install this device in an area that contains dust, greasy vapour and/or corrosive elements.

  • The device must be installed on a suitable wall surface in proximity to a fume disposal flue
  • It is vital to leave the minimal distances around the device as shown in fig 3 to allow for maintenance operations to take place.

LOCATION

  • The water heater must not be tightly placed in an enclosure or slot, it should have an adequate flow of air around it
  • The water heater must not be placed above a kitchen or other cooking devices that might deposit grease vapour on its exterior leading to corrosion
  • Surfaces that sensitive to heat (e.g. wood) must be protected using appropriate insulation.
  • Fig. 2 shows the dimensions necessary for wall mounting.

Room ventilation

  • The installation of the water heater must comply with regulations in force including any updates.

Warning

  • This device can only be installed in venues that are permanently ventilated according to regulation in force.

AIR CIRCULATION

It is vital that areas where gas devices are installed (type B) have access to the amount of air necessary for the regular combustion of gas as well as the ventilation of the venue.

  • It is prohibited to use an extractor fan, fireplaces and other similar devices at the same time as the water heater
  • The area where the water heater is installed must have a regular flow of air for ventilation.

AIR FLOW

The flow of air must occur by the following means:

  • Permanent openings in the wall that lead outdoors
  • Single or collective ventilation ducts.

The air used for ventilation must be taken directly from an outside location, that is far from sources of pollution.

Indirect ventilation from adjacent areas are permitted with the following limitations:

  • The adjacent area is equipped with direct ventilation
  • The devices within the area to ventilate are connected to a waste duct
  • The adjacent area does not contain a bedroom and is not a common area;
  • The adjacent area is not a fire hazard such as a storage area for flammable materials, garage etc.
  • The adjacent area is not lower than the area to ventilate as this might lead to an opposing draught (this can be caused by other devices that operate on the basis of combustion, a fireplace or any suction device that have not been given an adequate air supply)
  • The air flow from the adjacent area occurs freely through permanent openings.

Electrical connection to battery (fig. 4)

The device is powered by a 1.5 V battery, alkaline long lasting model LR20, thus it is not necessary to connect the device to a power socket.

Gas Connection

Determine the pipe diameter according to current regulations.
Before installing the device blow in the gas pipe to eliminate any residue from its manufacturing.

Connect the water heater to the internal system’s gas pipes and place a tap above the device for the halting and release of gas. The water heaters that are powered by tanks of L.P.G. gas with regulation and interception devices, must be connected correctly so to guarantee the safety of persons and the surrounding area. Follow all related regulations. Do not use a conical seat fittings or union conical with threading sealed with hydraulic hackled hemp or teflon. The water heaters that are powered by tanks of L.P.G. gas with regulation and interception devices, must be connected correctly so to guarantee the safety of persons and the surrounding area.
Follow all related regulations.

When initially installing the device qualified persons must perform the following tests:

  • Check that the internal and external parts of the gas supplying device are sealed;
  • check that the gas quantity supplied is equal to that required by the device;
  • check that the device receives the type of gas it is manufactured to process;
  • check that the gas supply pressure does not go beyond the maximum pressure values displayed on the information plate;
  • check that the gas supply system supplies the necessary amount of gas to the device and that it is equipped with all the necessary safety devices prescribed by current regulations.

If the user is absent for a lengthy period, turn off the main gas supply tap.
Do not obstruct the area’s ventilation openings where the device is installed to avoid dangers such as the build up of toxic and explosive substances.
Do not utilize gas tubes to earth electrical devices.

Water connection

Connect the water heater to the water supply and insert a tap to intercept the water above the device. From the front, the cold water input is on the right and the hot water output is on the left.

WARNING

  • Insert the filter into the water valve input fitting.
  • Remove the plastic nut from the hot water output fittin before connecting it to the water supply.
  • Check the water hardness (°f).
    • If is very hard, fit, upstream from the appliance, a device for softening water or another comparable mechanism that complieswith the applicable regulations.

Ensure that the tubes of you water system are not used to earth your electrical system or telephone, they are absolutely inappropriate for performing this task.
In a short amount of time this can damage tubes and the device.

Disposal of flue pipe connection

  • B11BS appliance is equipped with a flue gas safety device and it must be connected to a proper exhaust flue pipe.
  • In order to guarantee right operation of the device, suggested minimum exhaust pipe vertical length is defined in picture 6.
  • What above mentioned must be considered as installation suggestion only and it does not substitute local regulation in force.
  • For gas water heater installation it is mandatory to refer to updated local regulations.
  • The gas devices with an attachment for a waste gas flue must be connected directly to properly working chimney or flue pipe; only if these devices are not present is it then permitted to release gases directly outside.

The fitting of devices to a chimney or flue pipe must occur via a smoke channel. Smoke channels must be connected to a chimney or a smoke channel in the same or adjacent area to where the device is installed and must be made of materials resistant to mechanical strain, heat and the effects of combustion by-products and their condensation. The flue gas temperature must always be above condensation temperature in all points of the smoke channel regardless of external conditions.

FLUE GAS RELEASE SAFETY DEVICE

The product is equipped with a series of flue gas release safety devices. The device ensures the correct release of combustion by-products; the flow of combustible gas to the release conduit and the flue chimney. The safety device contains a “thermostat”, it can stop the flow of gas to the main burner and the pilot flame. The safety device can be triggered by the partial or total obstruction of the release conduit or the flue chimney.

To reset the device, press the flue gas thermostat button (A – fig. 7) with a screwdriver and open the hot water tap again. If the device or its electrical connections breaks down, the product can not be put ON, it ensures a safe condition If the device or its electrical connections breaks down, the machine operation is blocked. If the machine is constantly blocked as a result of the flue gas safety device, it is necessary to request the assistance of a qualified technician according to law in force, to check the correct release of flue gas through the release conduit and/or the flue chimney, according to the installation regulation.

It is highly prohibited to attempt to modify or remove the flue gas safety device; this risks the safety of the user and persons in the area. Only a qualified technician who is authorised by the manufacturer can meddle with the safety device in order to check it’s functionality or to substitute it if necessary. If it is necessary to replace the device it is vital to only use “original parts” supplied by the manufacturer since it has been designed, studied and regulated to be fitted with the water heater.

WARNING

  • The ducts reach high temperatures, use pipes made of suitable material.
Gas Transformation

Transforming the product so it may receive a different type of gas can be easily performed even while it is mounted. The instructions for transforming and regulating the product to receive various types of gas are below.
This operation must be performed by qualified personnel according to law in force.

TRANSFORMATION FROM LPG TO METHANE GAS

Transforming the product so it may receive a different type of gas can be easily performed even while it is mounted.
Before any operation ensure that the gas supply is switched off.

SUBSTITUTION OF THE PILOT INJECTOR

  • Disconnect the pilot flame tube (fig. 8)
  • Remove the pilot injector (fig. 9)
  • Insert the injector contained in the transformation kit

SUBSTITUTION OF THE BURNER MANIFOLD

  • Remove the safety clip (fig. 10)
  • Remove the fixing clip (gas pipe-burner manifold) (fig. 10)
  • Loosen the fixing nut (gas pipe-gas valve)
  • Remove the gas pipe
  • Loosen the fixing screws of the burner manifold (fig. 11)
  • Remove the mounting bracket
  • Remove the burner manifold
  • Replace it with that contained in the gas transformation kit
  • Fix the lateral screws The manifold is already provided of injectors, it’s not necessary to replace them.

SUBSTITUTION OF THE MODULATION VALVE

  • Remove the cold water entry pipe loosening the nut
  • Loosen the screws indicated in fig. 12
  • Disconnect the microswitch’s cables
  • Loosen the nut shows in fig. 13
  • Remove the 4 screws shows in fig. 14
  • Turn to the right the water/gas group as shown in fig. 15
  • Extract the large spring and the small spring/modulation valve set (fig. 16)
  • Substitute the modulation valve with the one in the kit
  • Insert the valve and the large spring, taking care with the direction of the insertion and making sure that the drilled spring guide disc is in its correct position (fig. 16)
  • Remount the components operating in the opposite direction
  • Fix the nut shows in fig. 15
  • Connect the gas pipe to the burner manifold being careful to insert the two clip (safety and fixing clip)
  • Fix the nut (gas pipe-gas valve)
  • Reconnect the gas valve to the water supply

ENABLING THE GAS ADJUSTER

  • Remove the protective cap (fig. 17 – part. A)
  • Regulate the pressure screws so that the burner reaches the pressure indicated on the technical data.

Note: ensure that the gas pressure is at 20 mbar.

WARNING

  • After regulating seal the protective cap with paint, lacquer or other such materials.
  • Check that all the disassembled parts are perfectly sealed once the device is operational using a soapy solution.
  • Write on adhesive paper “device transformed”, including the date of the operation, the name and signature of the person who performed the transformation and attach it to the device near the older information plate.

Using The Appliance

Start-up of the appliance

The water heater is used for the production of instant hot water. The removal of hot water can be preformed by multiple taps. By turning on the relative tap, the main burner switches on heating the water that passes. These devices with a modifiable flame are particularly suited for usage with mechanical mixers and thermostats. This water heater, in contrast with other water heaters with a fixed flame, has a modulation valve to optimise the water heaters operation. It allows for the water to be heated using less water pressure and gas by modulating the flame according to the amount of water used, maintaining the water extracted at a constant temperature.

The water heater uses automatic variation that is “PROPORTIONAL”, able to change the gas consumption (modulating the flame) to respond to the amount of water extracted. This device is equipped with an electronic tool that is powered by a 1,5 V battery that automatically switches on the pilot flame and then the burner every time that hot water is extracted. The flame is switched on using a card that ionizes the flame.

  • Primo Eco 6 ic D: for the extraction of 2 to 3 l/min the temperature of the water supplied remains at 60°C, (in this case the has valve supplies the burner with the necessary quantity of gas proportional to the water supplied), above 3 l/min to 6 l/min the water temperature varies from 60°C to 40°C.
  • Primo Eco 11 ic D: for the extraction of 2,5 to 5 l/min the temperature of the water supplied remains at 60°C, (in this case the has valve supplies the burner with the necessary quantity of gas proportional to the water supplied), above 5 l/min to 11 l/min the water temperature varies from 60°C to 40°C.
  • Primo Eco 14 ic D: for the extraction of 2,5 to 7 l/min the temperature of the water supplied remains at 60°C, (in this case the has valve supplies the burner with the necessary quantity of gas proportional to the water supplied), above 7 l/min to 14 l/min the water temperature varies from 60°C to 40°C.

Ignition and switch off (fig. 18)

Ensure that the gas tap and all water taps are switched off

  • Turn on the Main gas supply tap or that of the gas tank if using Liquefied Petroleum Gas (L.P.G.)
  • Open the gas tap, not supplied with the device, placed immediately before the water heater on the gas input pipe
  • Rotate knob “Gas economizer” (fig. 18) towards the large flame (ONinnovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-24), during rotation, when the small flame is reached it is necessary to press lightly while turning until it reaches its destination.
  • When hot water is requested, the device automatically turns on the pilot flame, this lights the main burner.
  • When the hot water request has terminated (turning the water tap off) the burner automatically switches off, the device then awaits another heating request.

WARNING: Check the water temperature before any use.

  • If after 60 seconds it does not switch on, the flame detector interrupts the flow of gas and blocks the device.
  • To reuse the device after it has been blocked, close the hot water extraction tap and then reopen it to restart the sequence.
  • If within 60 seconds the device does not function it is blocked.
  • The device is built to function with normal water pressure; in addition a water temperature selector (fig. 18) is also supplied.
  • Rotate the knob completely to the left to obtain the maximum water output or completely to the right for the minimum water output.
  • The machine is switched off by rotating knob “Gas economizer” (fig. 18) to the (innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-25OFF) position.
  • When the water heater is not used for long periods close the gas supply tap or the LPG gas valve on the tank.
  • For the best operational results it is recommended to have a qualified technician service the machine at least once a year.

GAS ECONOMIZER

The device is equipped with a gas economizing device which is used to choose the temperature of the water so it may be supplied at the temperature necessary while saving gas. The economizing device is activated by turning the knob “Gas economizer” (fig. 18) until it reaches the picture of the small flame (MIN innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-24). Using the economizer limits the amount of heating when the hot water usage is modest (water supplied is already warm or there is a reduced usage, for example in summer).

DANGER OF FREEZING

If there is a possibility that the area where the device is stalled could reach below 0°C, the device must be emptied of all water contained.
If the flame should not propagate along the burner during the commissioning phase, proceed as follows:

  • Remove the case
  • Check the combustion air supply hole on the pilot burner (left side) is open. Reduce the aperture of the hole as required by operating on the relevant clip: rotate the latter until good propagation of the flame is obtained on the pilot burner and the main burner ignites correctly.
  • Complete closure of the hole on the pilot is not recommended.
  • Check that the gas control knob is positioned in the range indicated in figure 19.

Maintenance

  • To maintain the machine at maximum efficiency, have qualified personnel perform a maintenance check at least once a year.
  • Before cleaning or performing maintenance, opening or disassembling the panels, switch off the device and turn off the gas supply.
  • Check the main burner and the pilot flame, the ignition electrode, the safety valve and that there is no leakage.
  • Check that there is nothing obstructing the passages within the exchanger smoke channel. To clean the outside of the panels utilize a cloth with soap and water.
  • Do not use solvents, powders or abrasive sponges.
  • Do not clean the device and/or its parts with flammable materials (e.g. petrol, alcohol, diesel etc.).

REMOVING THE CASING

To remove the outer casing follow the steps below (fig. 20):

  • Remove the selector knobs (A and B)
  • Remove the screws (C)
  • Shift the casing upwards to free it from the upper and lateral hooks
  • Shift the casing forwards
  • To reinsert the casing, follow the above steps in reverse order.

Troubleshooting: problems and solutions

For the best functioning of the water heater, to prolong its lifetime and ensure that it is always safe, ensure that it is inspected at least once a year by a trained professional. The trained professional is to perform the following maintenance operations:

  • Remove any rust from the burner
  • Remove any deposit on the glow plug by the electrode
  • Clean the combustion tank
  • Check the ignition, switching off and general functionality of the device
  • Check that the gas and water tubes and connections are sealed

Warning: the flowing repair instructions are only to be performed by qualified and authorized technicians.

PROBLEM CAUSE SOLUTIONS
There is no spark –   Exhausted battery

–   Electrical cable of device is disconnected

–   Electrical card is broken

–   There isn’t sufficient water pressure

 

–   The membrane is broken

–   The electrode is damaged

–   Substitute

–   Insert

–   Test, substitute

–   Repair the device to guarantee pressure, rotate the selector

knob all the way to the right

–   Substitute

–   Substitute

The pilot does not switch on when there is a spark –   Safety device broken

–   No gas supply

–   Air in the gas tubes

–   Substitute

–   Open the gas tap

–   Release gas

The burner does not switch off when the water turns off –   Grime on the gas shutter

–   Valve piston or stem is locked in open position

–   Micro lever is locked in open position

–   If an LPG supply, check the gas pressure

–   Test, clean

–   Disassemble, clean and eventually substitute

–   Test

–   Regulate and if necessary substitute the tank pressure regulator

The exchanger blade becomes dirty in a small amount of time –   Poor draught or dusty surroundings

–   Yellow flame

–   Excess gas consumption

–   Check the smoke channel efficiency

–   Check the gas type and clean the burner

–   Check and regulate

There is a smell of gas – Due to the loss of gas in the tubes, check the tubes and find the leak – Do not activate electric switches or any object that produces

sparks in local area

There is a smell of gas –   It can be caused by obstruction in the flue gas circuit

–   Excess gas consumption

–   Check the efficiency of the smoke channel and the flue gas conduit

–   Check and regulate

Technical Data

Primo Eco 6 ic D Eco 11 ic D Eco 14 ic D
PIN Nr. 0476CS2173
Nominal power usage (Pn)                kW – kcal/h 11,6 – 9.980 19,3 – 16.600 24,3 – 20.900
Nominal Thermal range (Qn)            kW – kcal/h 13,2 – 11.350 21,7 – 18.660 27,2 – 23.390
Min power usage (Pm) (NG/GPL)     kW – kcal/h 5,8 – 4.990 8,7 – 7.480 / 9,6 – 8.260 9,7 – 8.340 / 12,3 – 10.580
Min Thermal range (Qm) (NG/GPL) kW – kcal/h 6,6 – 5.680 9,8 – 8.430 / 10,8 – 9.290 10,8 – 9.290 / 13,9 – 11.950
 

METHANE GAS

 

PROPANE

METHANE GAS  

BUTANO

PROPA- NO GAS METANO  

BUTANO

PROPA- NO
TIPO GAS
G20 G31 G20 G30 G31 G20 G30 G31
P.C.I. (15° C 1013 mbar) MJ/m3 34,02 88 34,02 116,09 88 34,02 116,09 88
WI (15° C 1013 mbar) MJ/m3 45,67 70,69 45,67 80,58 70,69 45,67 80,58 70,69
m3/h 1,40 2,30 2,88
Consumption
kg/h 1,03 1,71 1,69 2,15 2,11
Burner Pressure mbar 11,5 32,0 10,50 26,60 35,80 11,20 26,30 35,40
Ø pilot flame nozzle mm 0,35 0,25 0,35 0,25 0,35 0,25
Nr/Ø main burner nozzle Nr/mm 14×0,85 14×0,50 24×0,85 18×0,48+6×0,50 30×0,85 22×0,48+8×0,50
Ø gas connection 1/2” 1/2” 1/2”
Flue gas load

(max-min)

g/s 13,50

11,26

12,48

10,29

13,50

11,26

11,80

9,75

12,48

10,29

18,62

16,69

17,67

15,58

18,10

15,49

Flue gas temperature (max-min) °C 171-101 181-115 161-101 157-110 173-118 158-86 155-115 162-110
 

Country of destination – Category –

Nominal feed pressure (mbar)

 

GB – HR – IE – IT: II2H3P G20: 20 – G31: 37

CY – GB – IE – IT: II2H3+ G20: 20 – G30/G31: 28-30/37

HR: II2H3P G20: 20 – G31: 37 II2H3B/P G20: 20 – G30: 30

CY – GB – IE – IT: II2H3+ G20: 20 – G30/G31: 28-30/37

HR: II2H3P G20: 20 – G31: 37 II2H3B/P G20: 20 – G30: 30

NOx emission (EN26:2015 su HS) mg/kWh 37 29 26 61 20 34 56 16

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-26

DIMENSIONS AND WEIGHTS DEVICE PACKAGE DEVICE PACKAGE DEVICE PACKAGE
Height – Length – Depth mm 550-256-246 632-303-283 592-314-246 675-361-280 650-363-246 733-410-280
Weight Kg 8,5 10,2 11,80 13,10 14,0 15,40

Note: relative cold water temperature of 15 °C

Product Installation Instructions

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-12

  1. Probe
  2. Economiser
  3. Pilot burner
  4. Ignition electrode
  5. Limit thermostat
  6. Flue gas release safety device
  7. Release hood
  8. Heat exchanger
  9. Burner
  10. Battery box
  11. Hydraulic valve
  12. Temperature regulator
  13. Gas valve
  14. Gas pressure intake
  15. Gas input
  16. Electronic devices
  17. Gas adjustment screws

Primo Eco 6 ic D

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-13

Primo Eco 11 ic D

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-14

  • AC: Hot water
  • AF: Cold water
  • GAS: GAS

Primo Eco 14 ic D

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-15

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-16

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-17

GN3 Earth
SV2 Burner solenoid valve
SV1 Pilot solenoid valve
SW Micro water contact
NC Not utilized
V+ Positive feed
GN2 Negative feed
GN1 Micro water contact
T.L. Water limit thermostat
T.F. Flue gas thermostat
M.S. Micro water
B Battery box
nero black
verde green
arancione orange
marrone brown
rosso red
grigio grey

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-18

1 Release hood
2 Flue gas safety device
3 Water limit thermostat
4 Heat exchanger
5 Burner
6 Sensor electrode
7 Pilot burner
8 Ignition electrode
9 Injector
10 Hot water output
11 Pressure intake
12 Temperature selector
13 Venturi
14 Hydraulic valve
15 Gas flow adjustment screw
16 Water filter
17 Membrane
18 Cold water input
19 Economiser
20 Gas valve
21 Safety device
22 Gas filter
23 Battery
24 Electrical card
25 Microswitch
26 Probe

innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-19 innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-20 innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-21 innovita-Primo-Eco-6-ic-D-LPG-Gas-Water-Heater-FIG-22

Contact

Innovita S.r.l.

Documents / Resources

innovita Primo Eco 6 ic D LPG Gas Water Heater [pdf] Instruction Manual
6 ic D, 11 ic D, 14 ic D, Primo Eco 6 ic D LPG Gas Water Heater, Primo Eco 6 ic D, LPG Gas Water Heater, Gas Water Heater, Water Heater

References

Leave a comment