iGAGING 400-QC-05 Check Spindle Square Gauge

iGAGING-400-QC-05-Check-Spindle-Square-Gauge-product-image

Product Information

Specifications:

  • Product Name: Quick Check Spindle Square Gauge
  • Model Number: #400-QC-05
  • Patent: U.S. Pat Pend
  • Spindle Stem Size: 3/8 inch
  • Indicator Bezel Range: 0-0.25
  • Thread Size: #4-48
  • Squareness Error of Graduation: 0.0005
  • Contact Separation: 4 instrument units

Product Usage Instructions

Setting Zero:
Set Zero on surface #400-QC-05 by turning the Bezel of the dial indicators on a flatness surface. Ensure the instrument is mounted carefully on the spindle to minimize run-out error.

Squaring the Instrument:
To ensure squareness, follow the steps below:

  1. Set Zero on the gauge as per the instructions provided.
  2. Place the instrument on a good flatness surface.
  3. Turn the Bezel of the dial indicators to adjust the squareness.

Calibration:
The gauge comes pre-calibrated for easy and fast use. It is advisable to check calibration periodically to maintain accuracy.

Frequently Asked Questions (FAQ):

  • Q: How often should I calibrate the Quick Check Spindle Square Gauge?
    A: It is recommended to calibrate the gauge periodically to ensure accurate measurements. The frequency of calibration may depend on your usage frequency and working conditions.
  • Q: Can the squareness error be adjusted?
    A: The squareness error of the gauge is minimal (0.0005). It is pre-calibrated and generally does not require adjustment. Ensure proper mounting and handling for accurate results.

Quick Check Spindle Square Gauge

PRODUCT MANUAL
This gauge is pre-calibrated for fast and easy use. –

  • Item# 400-QC-05
  • Range: 0-0.25”
  • Graduation: 0.0005”
  • Contact separation: 4”
  • Spindle stem: Ф 3/8
  • Thread size: #4-48
  • Squareness: <=0.0005”iGAGING-400-QC-05-Check-Spindle-Square-Gauge-01

On Machine Surface Setup (Quick Setup)

  • This gauge is pre-calibrated with a squareness within 0.0005”.
  • Set the gauge on the machine surface and both dial will read zero.iGAGING-400-QC-05-Check-Spindle-Square-Gauge-02

On Machine Setup (Complete Setup)

  1. Step 1. Insert the gauge to the spindle
  2. Step 2. Use a marker to mark a dot under the left indicator contact (as a setup reference point); adjust the spindle height till the indicator reads zero.
  3. Step 3. Turn the spindle 180° and let the right indicator contact overlap on the marked dot. The indicator should zero. Otherwise, turn the dial indicator bezel till the indicator needle points to zero. – Gauge setup is completed.iGAGING-400-QC-05-Check-Spindle-Square-Gauge-03
  • X-axis adjustment
    • Turn spindle and let the gauge parallel to the X-axis.
    • Turn the spindle head around B and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.
  • Y-axis adjustment
    • Turn spindle and let the gauge parallel to the Y-axis.
    • Turn the spindle head around A and observe the needle reading of the two indicators; make necessary adjustment until both indicators share the same readings.

STATE OF CALIFORNIA WARNING:
Cancer and Reproductive Harm
www.P65Warnings.ca.gov

iGAGING – San Clemente – California
Copyright © 2023 iGAGINGiGAGING-400-QC-05-Check-Spindle-Square-Gauge-04www.iGAGING.com