URFOG logoINSTALLATION AND USE MANUALURFOG 01 2C PRO PLUS FAST 01 2C Easy Pump -

01-2C-PRO-PLUS FAST 01 2C Easy Pump

Installation and use manual model FAST 01 120 v/230 v rev. 22/08/2021

WARNING!
All UR FOG fogging systems should only be used with UR FOG-branded fluids.
It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl.
The conditions of use will be automatically accepted by breaking the security labels on the product.

PACKAGE CONTENT

AInside the package you will find:

  1. The machine FAST 01 2C
  2. 2 charged fog fluid cylinders of 600 ml each.
  3. A window sticker in order to indicate that the device is installed
  4. Installation and use manual.

INTRODUCTION OF THE PRODUCT

Thank you for purchasing UR Fog product.
The great patented technological innovations such as the liquid injection system, the disposable cylinders, the fact that they don’t need to be refilled, the ecological and economic system for the complete emptying of the cylinders, together with the heating system, all of them make the FAST fog generators the best fog devices with the best performance in the security market.
– Reliable: There are no high pressure pumps which lose fluid or tend to stop working.
There are no high pressure pumps that must be tested periodically.
UR Fog double cylinders technology is guaranteed to work in any condition.
– Competitive: Complete use of cylinders liquid avoiding any waste of liquid thanks to pressure control.
Low power consumption, fast and powerful.
– Simple: Machine easy to install and able to be integrated to any existing alarm system.

CONDITIONS OF USE AND WARNINGS

The fog generated by UR Fog does not create particular problems or injuries for a human being for a short stay in a fogged room if the system is used according to the manufacturer’s recommendations.
Generated fog is certified as safe for people and animals from an authorized international certification company and is proved that it does not leave any residual.
UR Fog systems are certified respecting European laws and regulations. Any certifications required in specific countries are a responsibility of the distributor of that specific country.
The documents related to certifications can be requested by mail to support@urfog.com.
It is not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway by the contact with substances based on glycol, water and alcohol. Any employee or worker that may be exposed to fog must be warned in advance and must be checked for any allergy to the substances listed above. At the date of printing of this manual it has never been pointed out any problem related to any allergy.
UR Fog is in no way responsible for any damage or condition of use that has not been required and specifically approved by any specific written request prior to the installation of its products.
For fog fluid please refer to UR Fog fluid safety data sheet published on the website and carefully read it at www.urfog.com.
Contact a doctor if for any reason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction, and in any case wash it immediately with water and soap. Do never stay for a long time in a room filled with fog.
Do not use charged cylinders that are not the ones suggested by UR Fog and never try to recharge them, they are made for a single use. Follow your national rules for the dispose of empty cylinders.
Keep UR Fog cylinders out of reach of babies and animals. The nozzle may be hot and touching it may cause burns.
Do not look directly into the nozzle.
Never use UR Fog products for any purpose that is not related to protection from thief or robbery (the choice of the conditions of use in case of robbery will be suggested by your security consultant).
Never use different fog fluids or add any other substance into the cylinders.
Do not use or keep charged UR Fog machines in vehicles and do never transport UR Fog before 24 hours since it has been shut off. During transport it must be not armed.

INSTALLATIONS TIPS TO INSTALL FOGGING SYSTEMS

Please observe the following instructions for installing UR Fog:

  1. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  2. Children should be supervised to ensure that they do not play with this appliance.
  3. The machine must be installed avoiding to obstruct escape routes.
  4. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause: falls down, injuries or any damage to persons.
  5. Do not look directly into the nozzle. Do not add any other substance into the cylinders.
  6. The nozzle may reach high temperatures, touch it may cause burns.
  7. When UR Fog produces fog avoid staying closer than 1 meter from the machine.
  8. When UR Fog is armed avoid staying closer than 50 cm from the nozzle.
  9. Before testing UR Fog, remember to report it in advance to the firefighters in your area to avoid false alarms.
  10. Remember to put warning labels about the presence of UR Fog on the windows.
  11. Report its installation to the firefighters in your area and eventually to other institutions if needed.
  12. It is necessary to add an external switch to separate the fog generator from the alarm system and it should be activated before the maintenance to avoid that input tests, for example, can activate the fog generator.
  13. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested minimum distance. Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first 3 seconds from the point where the machine is installed.
  14. Setting the shooting time interval between the minimum and maximum shown in the shooting table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue. A shot that goes far beyond the recommended seconds can create a residue problems in the room.
  15. UR Fog continues to be effective for up to 2 hours and 30 minutes without 220V or 110V main power thanks to the insulation system which maintains the temperature in the heating system.
  16. Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
  17. Install with a maximum inclination of 20°.
  18. Do not move the machine when it is still hot.
  19. The main body of UR Fog, which has the heating system enclosed inside a metal frame, should not be opened unless by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours UR Fog has been shut off. The internal part may reach really high temperature.
  20. Do not activate the UR Fog machine before the installation is completed.
  21. Insert the cylinders as the last procedure and verify the anti-tampering function.
  22. When the installation is finished, always test the system.
  23. From the moment of UR Fog activation, at least one hour is necessary to reach the minimum temperature needed for the fog shooting.
  24. Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.
  25. The external temperature of UR Fog can change from room temperature to 50 °C.
  26. The tip of a stranded conductor should not be soft-soldered where the conductor is subjected to contact pressure.
  27. The UR Fog machine should not be exposed to water spray or dripping.
  28. Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of the equipment.
  29. The content of the bags is mechanically predetermined and can be subject to variations +/- 10%

HOW TO ACTIVATE THE SYSTEM

DELL Command Power Manager Apps - icon 2 It is always recommended to fix the machine on a wall even when it is placed on a flat surface.
Always verify that the bracket or the support surface are suitable for the weight of the machine.
It is suggested not to install the machine behind walls in a limited closed area without a specific ventilation to prevent a possible overheating.
In case of installation at the ceiling, it is recommended to use the specific optional bracket.
In case of installation on a wall it’s possible to ask for a 7 cm nozzle extension.
DELL Command Power Manager Apps - icon 2 The cylinders supplied with the equipment are intended to be used only for a vertical (standard) installation. In case of horizontal installation, please refer to your authorized reseller/distributor to get the appropriate cylinders. I’s necessary to insert the cylinders with the black plastic plug.

After removing the machine from the package, unscrew the screws that stop the right side panel and remove it. Pay attention to the screw below on the left as it’s longer than the others, unscrew the anti-tamper screw from the internal part and then the screws of the cover. Inside it is possible to see the front part of the electronic circuit, from here on called PCB.
It is recommended to install the fogging system Fast 01 2C vertically. If it is needed to install Fast 01 2C horizontally, it is necessary to order a special machine prepared for such installation and strictly follow the installation instructions.URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - installation instructions

TECHNICAL SPECIFICATIONS

* Industrial standard as from other manufacturers
Weight without tanks
FAST 01 2C
22 Kg
Max fog emitted in a single shot 1200 m3
Max fog emitted with full cylinders 2400 m3
Fog tanks capacity 2 x 600 ml
Work time without mains power about 2,5 hours
Max power on heating system 2 X 300 w
Average power consumption during heating process 540 W
Heating time about 2,5 hours
Max consumption in steady state 60 W
Power consumption at 12V 500 mA while shooting 60 mA in stand by
Average batteries lifetime 12 months with 10 shots
Door tamper Tamper screw
Anti-tear off and anti-shift Accelerometer

DELL Command Power Manager Apps - icon 2 The “empty” signal does not mean only that the cylinder is empty, but also warns that the system is in reserve.
For this reason is very important to make the “reset” only when you actually exchange the cylinder or you will lose the seconds counting. (See paragraph 13)

WARNING:
– Loosened ferrule can cause dropping
– Do not disconnect the machine immediately after the shot
– Change batteries every year
– Change the cylinder as soon as the “empty” signal appears

POWER SUPPLY

230V or 110V power source supplies energy only to the heating system. The electronic board and the cylinder’s motors are supplied from the alarm system and batteries. The heating element is of 600W, at the very beginning power consumption is about 500W and in some minutes it goes down reaching average consumption of about 60W.
DELL Command Power Manager Apps - icon 2 Do not use: inverter or UPS unless you have the certainty that they generate a true sine wave, not a rebuilt one. Ask to the UPS manufacturer the correspondence of these characteristics before the installation.
– The max current to be considered for the system is 2,3 A
– The connection to the 230V or 110V electricity grid must be performed by a qualified technician.
– Connect the equipment to the electricity grid only after you have completed the installation.
– It is necessary to connect the ground terminal.
– The machine has to be connected to the power supply through a disconnecting device that has to brake both connections and must be thermo magnetic switch.

  1. Phase 220V / 110V
  2. Neutral 220V / 110V
  3. Ground connection
  4. Ground connection for heat exchanger and cabinet (never disconect)

URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - exchanger and cabinet

DELL Command Power Manager Apps - icon 2 IF YOU NEED TO REPLACE THE FUSE, USE THE ONE WITH EXACTLY SAME SPECIFICATIONS.
IF YOU HAVE DOUBTS, ASK TO YOUR AUTHORIZED DEALER.

ALCALINE BATTERIES POWER

N.B. It’s available an optional power supply with charger of NiMH batteries and relays outputs – see paragraph 10
The batteries are intended to maintain the efficiency of the electronic board, allowing the fog emission even in absence of power supply from the electricity grid, until the heating system has a sufficient temperature.
The batteries also have the purpose of activating the motors that lift up the plates holding the cylinders, even when the main power supply or 12 V from the alarm system is available.
Without batteries, with dead batteries, rechargeable or poor quality ones, the motors do not lift up the plates that push the cylinders.
For this reason it is important:
– To use only high quality alkaline batteries
– To replace them within the expiry date
– to replace them every 12 months anyway
– When Fast 01 2C report the signal of low battery (Paragraph 14-15)
– Test the battery case during every maintenance (Paragraph 15)
After inserting the batteries, it is important to check that they are in good contact with the battery case to guarantee the proper unctioning. For a description on how to make tests, refer to Paragraph 13.

VERIFICATION OF BATTERIES AND BATTERY CASE
You need to replace the batteries:
– After one year of use
– Within expiration date printed on them
– When it is reported they are exhausted.
If the batteries run out, a sequence of acoustic signals will start as follows:
– 2 bip / minute exhausting batteries
– 3 bip / minute machine can’t shoot, battery too low
– 10 bip / minute batteries are missing absent or bad contact on the battery case, plug or cable interrupted.
Any anomaly of the batteries also causes the activation of “fault” output, useful to remotely signal a possible anomaly.
When discharged batteries are removed from battery case, the buzzer will sound a sequence of 10 bips per minute.
After re-inserting the batteries, it is suggested to wait at least for one minute, in order to verify that the sequence of beeps is not repeated. If the sequence of beeps does not stop, you should verify the polarity of the batteries is correct and, in that case, that thebatteries are in contact with the battery case. At this stage, it may be useful to use a tester.
It is necessary to use high quality alkaline batteries.
It is possible to use lithium batteries – ask information to your retailer.
When you close the door, the buzzer will sound to confirm the anti-tamper system is correctly closed.

DESCRIPTION AND INPUT AND OUTPUT CONNECTIONS

INPUTS

  1. + 12 V Power input
  2. GND Power input
    In these inputs is necessary to provide a stable supply, between 11V and 14V C.C. from the alarm control panel or from an external 12V power supply. This power is necessary to the operation of the LED and for the logic of operation.URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - CONNECTIONS In the absence of voltage on this input, the logic part will continue to operate, but the heater will not. For about 2 hours and 30 minutes, or until the temperature of the heat exchanger (heating system) will allow, Fast 01 may produce fog. The maximum current drawn from UR Fog on this input is 230 mA.
  3. RM Arming input
    By connecting this input to positive, Fast 01 2C is armed, blue frontal led is switched on and when the machine reaches proper temperature it means that it is ready for shooting.
  4. SHOOT shooting input
    Putting this input to positive, if Fast 01 2C is hot and armed, starts fog emission for the set time (see paragraph 11) In case of alarm, when opening ARM input, the fog emission stops immediately, even if the time set wasn’t reached.
  5. GND Negative reference
    OUTPUTS
  6. EMPTY Empty cylinder output
    This output (NPN Open Collector) closes towards negative direction when at least one of the two cylinders is empty.
  7. FAULT Fault output
    This output (NPN Open Collector) closes towards negative when there is a serious malfunction (such as expired batteries, fault of power supply or temperature control fault), which compromises the functioning of the device and which requires a technical action. Fault signal due to supply absence has a delay of 20 minutes.
  8. TAMPER Tamper output
    This output (NPN Open Collector) closes towards negative direction when you open the door cylinders or when the accelerometer detects a sudden movement (such as the detachment from the wall).
  9. GND Negative reference

FOG FLOW DIRECTION
To ensure the right direction to fog flow, it is recommended to insert a screwdriver of the diameter of the hole and, without forcing, orient the nozzle in the correct direction.
This allows you to clearly see the direction and keep it in place while tightening.
To screw and unscrew the nozzle, you should use a pair of pliers in good condition, to avoid damaging the plating.
Do not overscrew the nozzle, it is sufficient that the Teflon nozzle does not move.
Do not flow directly on objects or walls less than 2 meters away or to the floor if it is installed at a height lower than 2.50 meters. During first two shots, teflon sphere settles, so it is needed to tighten it again.

URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - FOG FLOW DIRECTION

URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - WARNING WARNING!! After fog emission and for few minutes, the nozzle is very hot. RISK OF BURNS IF TOUCHED by bare hands.
DELL Command Power Manager Apps - icon 2 Remember, it is necessary to connect all three outputs to an alarm central or an electronic panel that can see all those information in real time and take proper action.
In order to avoid accidental activation with subsequent fog emission, the inputs are in “negative security”, for this reason the disconnection of a wire does not cause activation.
So it is necessary to check carefully the reliability of connections and protect the cables to the control panel to avoid the risk of accidental damages.

IMPOSTAZIONE DEL TEMPO DI SPARO E DIREZIONE DEL FLUSSO DI NEBBIA

BLUE LED
When on: it means that the machine is armed and ready to shoot, if the heater has reached the working temperature.
When flashing: means that something is wrong.
See paragraph 15 ”Faults and possible solutions”
RED LED
When on: means that at least one cylinder is empty.
See paragraph 13 ”Cylinders exchange and reset”
GREEN LED
When on: Fast 01 2C is hot and ready for fog emission.
When flashing: means that the heating process is in progress.
Fast 01 is not ready to shoot.URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - BLUE LED

DELL Command Power Manager Apps - icon 2 IF BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND FROM THE BUZZER, AN ANOMALY IS DETECTED. SEE PARAGRAPH 16 “RESET FROM FAULT CONDITION”.

SHOOTING TIME SETTING

To set the shooting time, after opening the cylinders compartment door as showed in Paragraph 5, at the top of the PCB, you must put the jumper P3 in “setting” position.
Then, holding down the S1 “SET”, 3 LEDs on the front will start flashing and each flash is equivalent to one second.If you press the button again, the shooting time is not added to the one previously set, but will restart from zero.
N.B. The button in the cylinders compartment showed in next paragraph, is linked to Set/Reset button.
Therefore, after setting shooting time, it is recommendable to place the P3 jumper in RESET position (right side), in order to make this operation without removing the cover and avoid to zero shooting time.

URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - TIME SETTING

N.B. Before opening side door ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or tamper” circuit does not cause any shooting.
N.B. To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one supposed for the theft.

RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m3)
Systems FAST 01 2C are able to produce fog for a maximum respectively 70 seconds per single shot. The maximum quantity of 10,7 ml/s allows to fill an area of about 1200 m3. There might be cases in which, due to specific characteristic of the location, nozzle type, levels of temperature and air pressure, degree of the fog density and light in the target area, the shooting time can be increased. For example, above 5 m of height the shooting time must be integrated and above 7 m , every additional meter should be considered as double.

(HxLxP) x D x V x R x I
HxLxP——– Height x Width x Depth of the area to protect
D————- Density of the produced fog
V————- Temperature and air pressure
R————- Acceptable residue in case of saturation of V parameter
I————– Intensity of the surface light

The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of temperature, air pressure and humidity.

TABLE OF SHOOTING FAST 01 2C

Seconds of emission m³ to protect
1 16-19 (57*)
2 32-39 (117*)
3 48-58 (174*)
4 64-77 (231*)
5 80-96 (288*)
6 96-116 (348*)
7 112-135 (405*)
8 128-154 (462*)
9 144-173 (519*)
10 161-193 (579*)
11 177-212 (636*)
12 193-231 (693*)
13 209-250 (750*)
14 225-270 (810*)
15 241-289 (867*)
16 257-308 (924*)
17 273-327 (981*)
18 289-347 (1041*)
19 305-366 (1098*)
20 321-385 (1155*)
21 337-404 (1212*)
22 353-424 (1272*)
23 369-452 (1356*)
24 385-462 (1386*)
25 401-482 (1446*)
26 417-501 (1503*)
27 433-520 (1560*)
28 449-539 (1617*)
29 465-559 (1677*)
30 482-578 (1734*)
31 498-597 (1791*)
32 514-616 (1848*)
33 530-635 (1386*)
34 546-655 (1965*)
35 562-674 (2022*)
36 578-693 (2079*)
37 594-713 (2139*)
38 610-732 (2196*)
39 626-751 (2253*)
40 642-770 (2310*)
41 658-790 (2370*)
42 674-809 (2427*)
43 690-828 (2484*)
44 722-867 (2601*)
45 706-874 (2622*)
46 738-886 (2658*)
47 754-905 (2715*)
48 770-924 (2772*)
49 786-944 (2832*)
50 803-963 (2889*)
51 819-982 (2946*)
52 835-1002 (3006*)
53 851-1021 (3063*)
54 867-1040 (3120*)
55 883-1059 (3177*)
56 899-1079 (3237*)
57 915-1098 (3294*)
58 931-1117 (3351*)
59 947-1136 (3408*)
60 963-1156 (3468*)
61 979-1175 (3525*)
62 995-1194 (3582*)
63 1011-1213 (3639*)
64 1027-1233 (3699*)
65 1043-1252 (3756*)
66 1059-1271 (3813*)
67 1075-1290 (3870*)
68 1091-1310 (2622*)
69 1107-1329 (3987*)
70 1124-1348 (4044*)

* Industrial standard as from other manufacturers

The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the second column. The value in m³ varies depending on the density to be obtained.
Within the second column, the first value allows to get the maximum density recommended to ensure the absence of any residual, while with the second value you get minimum recommended visibility of according to the standard CENELEC, whereas a higher visibility would make the fog superfluous. In places where a little residual causes no problems, it is possible to increase the shooting time.
Please note that the higher the fog released, the more the time required to recover visibility. High levels of fog, over recommended limits, can leave residual. Any residual generally disappears in 24/48 hours without intervention, otherwise, it is sufficient a damp rag to clean. If you want to get a visibility of one meter after 60 seconds as required by standards, which is used as a reference by all manufacturers of Fog Cannons, the number of shooting seconds must be reduced by half.

CONNECTION EXAMPLES

The diagrams and examples below are intended to provide only for a “better understanding” of the operation of the inputs / outputs. None of the diagrams below represents the “single scheme to perform” as, in respect of the reference standard, there are specific indications and only using all inputs and outputs on the PCB it is possible to abide by the standard.
For a connection in “anti-robbery mode” it’s necessary a careful evaluation of the risks by a security consultant.

A Example of connection FAST 01 2C inputs with outputs of a central antitheft
B Example of connection of the FAST 01 2C outputs to drive LEDs and / or relays
C Example of connection of the FAST 01 2C outputs with inputs of an antitheft normally opened with diods needed only with some equipments.
D Example of connection of the FAST 01 2C outputs with balanced inputs of an antitheft
E Example of connection of the FAST 01 2C  outputs with relay board

A – Example of connection FAST 01 2C inputs with outputs of a central antitheft

URFOG 01 2C PRO PLUS FAST 01 2C Easy Pump - central antitheft

URFOG 01-2C-PRO-PLUS FAST 01 2C Easy Pump - 1N.B. Ask for the PDF module writing to: support@urfog.comURFOG logo

UR Fog S.r.l. Via Toscana 38 – 10099 San Mauro T.se (Torino) – Italy