HoneyWell

Honeywell N-ADV-134-H Advanced Controller

Honeywell-N-ADV-134-H-Advanced-Controller

Specifications

  • Dimensions:
    • Height: 5.91 inches (150.2 mm)
    • Width: 5.51 inches (140 mm)
    • Depth: 4.7 inches (119.4 mm)
  • Mounting Options: Wall mount or DIN rail
  • Operating Environment:
    • Vibration during operation
    • Altitude: Up to 13123 ft (4000 m)
    • Protection: IP20 with optional terminal cover
  • Power Consumption:
    • 24 VAC: Max. 1500 mA
    • 24 VDC: Max. 540 mA
Specification Detail
Electrical Consumption (Controller) 24 VAC / 24 VDC
Models N-ADV-134-H / N-ADV-133-H / N-ADV-112-H
Current Consumption 1500 mA / 520 mA (24 VAC) / 1420 mA / 520 mA (24 VDC)
Surge Protection Protection against surges up to 29 VAC or 40 VCC. Terminals protected against short-circuits.
Operating Environment Storage Temperature: -20 to 158 °F (-28.9 to 70 °C); Operating Temperature: -13 to 140 °F (-25 to 60 °C); Humidity: 5 to 95% RH (non-condensing); Operational Vibrations: 0.024″ double amplitude (2 to 30 Hz), 0.6 g (30 to 300 Hz); Compliance: Conforms to standard EN 60730-1; Protection: IP20 with optional terminal cover; Altitude: 13123 ft (4000 m).
Standards and Approvals UL60730-1, UL60730-2-9, UL916, IEC/EN 60730-1, Energy management equipment, CE/EN 60730-2-9, CAN/CSA-E60730-1/02, CEI/EN 61326-1, et CEI/EN 61010. Energy metering EN 52120 et EN 12098.
Certifications UL60730-1, UL916, CE, BTL B-BC, BACnetTM 135 version 1.14, ISO 16484-5, FCC Part15, WEEE, C-tick RCM, Subpart B, CAN ICES-3 (B)/NMB-3(B), RCM, AMEV AS-B, KBOB, EAC, RoHS II, Ethernet protocol version IEEE 802.3, EN-1434-3, and EN-13757-3.
Shock Protection IP20
Pollution Degree Class B
Software Class Class B

Product Usage Instructions

Mounting the Controller

  1. Identify the mounting location and ensure it meets the specified conditions.
  2. For DIN rail mounting:
    • Align the controller on the DIN rail.
    • Push all red clips to secure the controller in place.
  3. For wall mounting:
    • Securely attach the controller to the wall using appropriate screws.

Connecting Terminal Blocks

  1. Mount the adapter so that the edge connector aligns with the edge hook of the controller.
  2. Gently press to engage the clips and secure the connection.

Removing the Controller

  1. To remove from DIN rail, release all red clips and slide off the rail.
  2. To remove from the wall or panel, unscrew and detach thecontroller carefully.

 Box Contents

  • Controller: Qty: 1
  • Mounting Instructions: Qty: 1
  • Safety Data Sheet: Qty: 1

Storage and Operating Conditions
The storage and operating conditions include temperature ranges and humidity levels:

  • Temperature for storage: -20 °F to 158 °F (-28.9 °C to 70 °C)
  • Temperature for operation: -13 °F to 140 °F (-25 °C to 60 °C)
  • Humidity: 5% to 95% relative humidity (non-condensing)
  • Avoid exposure to dripping or splashing liquids, and do not place objects filled with liquids, such as vases, on the equipment.

Dimensions

  • Width: 5.91 inches (150.2 mm)
  • Height: 4.7 inches (119.4 mm)
  • Depth (with connectors): 2.36 inches (60 mm)
  • Depth (without connectors): 2.26 inches (57.5 mm)

Wall or DIN Rail Mounting of the Controller

  1. Mount the DIN rail on the wall or panel with the help of screws.
  2. Remove the lower terminal cover of the controller by using a flat-blade screwdriver to push the cover upwards.
  3. Remove the upper terminal cover in a similar manner.
  4. Deploy all the red unlocking clips to the mounting position by inserting a flat-blade screwdriver and moving it from the lower slot to the upper slot, as shown in the diagram.
  5. Maintain the controller in an orientation that the red clip is towards the bottom and towards the DIN rail.
  6. Mount the controller on the DIN rail and push all the red clips to lock it in place.
  7. Connect the power wires and Ethernet cables.
  8. Reattach the terminal covers.
  9. If attaching the protection cover or if the E/S module fixation is not required, this cover must be mounted to protect the contact terminals on the side of the controller. The cover also includes a transmission resistance for the bus E/S terminals, which should always be located at the bus E/S terminal end.

Technical Documentation References

For further details on the Advanced Controller, please refer to the following technical documents:

  • Advanced Product Data Sheet – 31-00583
  • Optimizer Product Data Sheet – 31-00631
  • Installation Instructions and Service Guide – 31-00584

Contact Information:

Honeywell Building Technologies
715 Peachtree Street, N.E.,
Atlanta, Georgia, 30308, United States.
Honeywell Building Technologies

FAQ

What are the power consumption specifications for the Advanced Controller?

The Advanced Controller consumes a maximum of 1500 mA at 24 VAC and 540 mA at 24 VDC.

What mounting options are available for the Advanced Controller?

The Advanced Controller can be mounted either on a wall or on a DIN rail.

What are the operating environment specifications for the Advanced Controller?

The controller is designed to operate in environments with vibrations and altitudes up to 13123 ft (4000 m), with IP20 protection when using optional terminal covers.

What is the operating temperature range for the Advanced Controller?

The operating temperature range is -13 °F to 140 °F (-25 °C to 60 °C).

How is the Advanced Controller mounted?

The controller can be mounted on a wall or on a DIN rail.

What should be done if the E/S module fixation is not required?

If the E S module fixation is not required, the protection cover must be mounted to protect the contact terminals on the side of the controller.

What certifications does the Advanced Controller have?

The controller has multiple certifications, including UL60730-1, UL916, CE, BTL B-BC, BACnetTM 135 version 1.14, ISO 16484-5, FCC Part15, and more as listed in the specifications section.