DELTA-LOGO

DELTA Aux Power Board DC Wallbox Smart Charge EV Charging Electronics DC Wallbox

DELTA-Aux-Power-Board-DC-Wallbox-Smart-Charge-EV-Charging-Electronics-DC-Wallbox-PRODUCT

Product Specifications

  • CHAdeMO CSU (BA board) FW version: V02.07.12.41
  • CCS CSU (CA board) FW version: V01.0C.03.01
  • Relay Ctrl Board FW version: V01.03.02.00
  • Aux Power Board FW version: V00.04.05.00
  • Update time
    • CHAdeMO CSU: 10 minutes
    • CCS CSU: 30-60 minutes
    • Relay Ctrl Board: 10 minutes
    • Aux Power Board: 10 minutes
  • Compatibility
    • BA FW V02.05 or higher with CA FW V01.0B or higher
    • Old BA FW (V01.3x or lower) with Old CA FW (V01.06 or lower)

Product Usage Instructions

Sequence/Condition of FW Update

  • No sequence requirement for BA, CA, Relay Ctrl BD update.
  • All can be updated via USB or OTA.
  • Can update one by one or all together.

Downgrade

  • Sequence: Relay Ctrl BD > BA > CA. Condition: Relay Ctrl BD downgrade needs to be based on New BA FW. No sequence and no condition requirement for BA, CA downgrade.

How to Update FW

Via USB

  1. Put FW file (one or all) in the USB stick root path.
  2. Insert the USB stick into the USB port (on the bottom of the DCWB unit or BA board). The update process will start automatically.
  3. Remove the USB stick after the update is completed.

Via Folder

  1. Create a folder named DCWB25kW, and put all FW files in this folder.
  2. Zip this folder to be DCWB25kW.zip.

How to Confirm the FW Version

  • [Provide instructions on how users can check and confirm the current firmware version of their product.]

FAQ

  • Q: Can I downgrade the firmware without any conditions or sequences?
  • A: Yes, you can downgrade BA and CA firmware without any sequence or condition requirements.

Upgrade Instruction

DA07_ DCWB FW V02.07 Upgrade Instruction

FW version for each module

Module FW version Update time FW file name
CHAdeMO CSU (BA board) V02.07.12.41 10 min 5062640816
CCS CSU (CA board) V01.0C.03.01 30~60 min 5062639506
Relay Ctrl Board V01.03.02.00 10 min 5062586104
Aux Power Board V00.04.05.00 10 min 5062572502

Compatibility

  • BA FW V02.05 or higher with CA FW V01.0B or higher
  • Old BA FW (V01.3x or lower) with Old CA FW (V01.06 or lower)
  • New Relay Ctrl BD FW (V01.03 or higher) is compatible for all New and Old BA CA, but Old Relay Ctrl BD FW (V01.03.00.00 or lower) is not supported to New BA CA.

For example

BA fw CA fw Relay fw Result
V02.07 ~ V02.05 Old V01.0C V01.0B Old New Old
V   V V   V   OK3
V       V V   NG1
  V V V   V   NG1
  V     V V   OK
V   V V     V NG2
V       V   V NG1
  V V V     V NG1
  V     V   V OK

Note

  1. Cannot do CCS charging, CHAdeMO charging is available
  2. Without the function of relay control board
  3. The new function Auto PEV Authorize must be executed on BA V02.07 and CA V01.0C software

The sequence/condition of FW update
Upgrade

  • No sequence requirement for BA, CA, Relay Ctrl BD update
  • All can be updated via USB or OTA
  • Can update 1 by 1 or all together

Downgrade

  • Sequence: Relay Ctrl BD→BA, CA
  • Condition: Relay Ctrl BD downgrade needs to be based on New BA fw.
  • (Relay Ctrl BD will update failed without New BA fw)
  • No sequence and no condition requirement for BA, CA downgrade

How to update FW

  • Via USB

Method

  • Step 1. Put FW file (one or all) in USB stick root path
  • Step 2. Insert the USB stick into USB port (on the bottom of the DCWB unit or BA board). The update process will start automatically
  • Step 3. Remove the USB stick after the update is completed

Method

  • Step 1. Create a folder named DCWB25kW, and put all FW files in this folder
  • Step 2. Zip this folder to be DCWB25kW.zip

DELTA-Aux-Power-Board-DC-Wallbox-Smart-Charge-EV-Charging-Electronics-DC-Wallbox-FIG-1

  • Step 3. Put DCWB25kW.zip in USB stick root path
  • Step 4. Insert the USB stick into USB port (on the bottom of the DCWB unit or BA board). The update process will start automatically
  • Step 5. Remove the USB stick after the update is completed
  • Put FW file (one or all) in a USB stick

Via OCPP Backend

  • OTA update the FW file one by one or update the DCWB25kW.zip

ATTENTION

  • Even though the CA fw update is successful, the LCM shows “update failed”. To confirm whether the CA fw is updated successfully or not by checking it from the Log file.
  • When performing Aux Power BD remote FW update (both upgrade or downgrade), the backend system will NOT receive the “update successful” message, because Aux Power BD is reset once the FW update is finished. To confirm whether the CA fw is updated successfully or not by checking it from the Log file.

How to confirm the FW version

  • Insert a USB stick into the charger, system log file will be downloaded automatically to the USB stick.DELTA-Aux-Power-Board-DC-Wallbox-Smart-Charge-EV-Charging-Electronics-DC-Wallbox-FIG-2
  • Copy the log file to the computer, and unzip it with the password “SN@delta” Ex: JGD184700031WE @delta
  • Open the file- DownloadConfiguration. The key information of the FW version is indicated in the first 4 paragraphs.

DELTA-Aux-Power-Board-DC-Wallbox-Smart-Charge-EV-Charging-Electronics-DC-Wallbox-FIG-3

Documents / Resources

DELTA Aux Power Board DC Wallbox Smart Charge EV Charging Electronics DC Wallbox [pdf] Instructions
DA07, BA board, CA board, Relay Ctrl Board, Aux Power Board, Aux Power Board DC Wallbox Smart Charge EV Charging Electronics DC Wallbox, Aux Power Board DC, Wallbox Smart Charge EV Charging Electronics DC Wallbox, Smart Charge EV Charging Electronics DC Wallbox, Charge EV Charging Electronics DC Wallbox, EV Charging Electronics DC Wallbox, Charging Electronics DC Wallbox, Electronics DC Wallbox, DC Wallbox, Wallbox

References

Leave a comment

Your email address will not be published. Required fields are marked *