DH-Lifelabs-LOGO

DH Lifelabs Sciaire Pro H110 Carbon Fiber Brush Output Ionizer

DH-Lifelabs-Sciaire-Pro-H110-Carbon-Fiber-Brush-Output-Ionizer-PRODUCT

Product Information

  • Product Name: Sciaire Pro H110
  • Model Number: H110-240GR
  • Manufacturer: Dernier & Hamlyn Inc.
  • Address: 720 Northgate Parkway Wheeling, IL 60090
  • Technology: The Sciaire Pro Air Ion Generator uses PlasmaShieldTM Technology.
  • Power Source: The ionizer is self-contained and does not require an external power supply. It can accept 100-240V AC.
  • Safety Information: Please read all safety instructions before using the device. Adhere to the mentioned safety precautions to reduce the risk of fire, electric shock, or injury.
  • EPA Registration: EPA EST. NO. 99117-CHN-1
    Country of Origin: Made in China

Product Usage Instructions

Installation

  1. Complete the mechanical installation before connecting the device to power.
  2. Mount the unit near the fan inlet using the provided mounting flanges and screws. Ensure that the air stream flows over the two brush tips simultaneously.
  3. Install the unit downstream of the filter.
  4. Avoid installing the unit directly after a cooling coil or humidifier.
  5. If using exit ducts, it is recommended to install a group of plasma generators every 20 meters to ensure ion concentration.
  6. In larger rooms, add a group of plasma generators in the middle near the outlet with a 1-2 meter distance to ensure the concentration of ions in the room.

Electrical Installation

  1. All field wiring should be done in accordance with NEC and Authorities Having Jurisdiction (AHJ) guidelines.
  2. It is recommended to install surge protection at the equipment level, building level, or circuit breaker panel feeding the product.

Note: For detailed electrical installation instructions, please refer to the instruction manual provided with the product.

Your safety is important to us.
Read all safety instructions before you use the device.

WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY PLEASE ADHERE TO THE FOLLOWING:

  • DO NOT connect to power before installation is complete.
  • Always disconnect power to the ionizer before handling.
  • All field wiring needs to be  in accordance with NEC and Authorities Having Jurisdiction (AHJ).
  • It is recommended that surge protection be installed with this ionizer at the equipment level, building level, or circuit breaker panel feeding the product.
  • If a step-down transformer is used to feed the ionizer, the transformer must be grounded.
  • Do not install the ionizer on the same circuit as a UV Lamp or connect to the same transformer as a UV Lamp.
  • Connect power to the ionizer using appropriate voltage.
  • The installer shall provide a power source that is properly grounded per the local AHJ.
  • For best results interlock ionizer with fan power.
  • Apply power to unit. Confirm that green indicator light illuminates showing that the ionizer is on and functioning properly.

RISK OF ELECTRIC SHOCK

  • These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
  • Read all safety instructions in the instruction manual, and on the device.

Product Description

  • Sciaire Pro H110 is a carbon fiber brush output ionizer producing positive and negative ions. This ionization equipment is effective in reducing harmful pathogens, pollutants, and odors by introducing positive and negative ions into the system airflow.
  • Sciaire Pro H110 is self-contained in a potted enclosure which has molded flanges with mounting holes. These models are able to accept 100-240V AC without the use of an external power supply.

Product OverviewDH-Lifelabs-Sciaire-Pro-H110-Carbon-Fiber-Brush-Output-Ionizer-FIG-1

  1. Plasma Generator
  2. ST4.2 Screw (x2)

Installation

WARNING: DO NOT CONNECT TO POWER BEFORE MECHANICAL INSTALLATION IS COMPLETE. ALWAYS DISCONNECT POWER BEFORE HANDLING.

  1. Mount Sciaire Pro H100 in a location with general maintenance access. Ensure the brush tips are not within ¾” of any metallic surface to prevent arcing.
  2. Mount the unit at or near the fan inlet using the holes in the mounting flanges, ensuring that the air stream flows over the 2 brush tips simultaneously. See graphic below for reference.
  3. The unit should be mounted downstream of the filter.
  4. Avoid locations directly after a cooling coil or humidifier.
  5. Exit ducts are recommended to install a group of plasma generators every 20 meters to ensure ion concentration.
  6. Add a group of plasma generators in the middle near the outlet with a 1-2 meters distance to ensure the concentration of ions in the room.DH-Lifelabs-Sciaire-Pro-H110-Carbon-Fiber-Brush-Output-Ionizer-FIG-2

Electrical Installation

  1. All field wiring to be in accordance with NEC and Authorities Having Jurisdiction (AHJ).
  2. It is recommended that surge protection be installed with this ionizer at the equipment level, building level, or circuit breaker panel feeding the product.
  3. If a step-down transformer is used to feed the ionizer, the transformer must be grounded (recommended 20 VA minimum).
  4. Do not install the ionizer on the same circuit as a UV Lamp or connect to the same transformer as a UV Lamp.
  5. Connect power to the ionizer using appropriate voltage.
  6. The installer shall provide a power source that is properly grounded per the local AHJ.
  7. For best results interlock ionizer with fan power.
  8. Apply power to unit. Confirm that green indicator light illuminates indicating that the ionizer is functioning properly.

Operation

  1. When power is supplied to the ionizer, the ionizer will be activated, and the green ion indicator LED will illuminate.
  2. The ionization unit is self-balancing and does not require any type of adjustment.

Sequence of Operation

For units that are interlocked with the supply fan control, the BAS controls the start/stop of the air conditioning unit supply fan.

Device Specifications

Model H110-240GR
Voltage Input 100-240V AC
Humidity Range 0%~85%
Unit Dimensions 3.7 x 2.4 x 1.2 in (94 x 60 x 30 mm)
Power Consumption 2.2W
Weight 0.27lbs (121g)
Temperature Range -4˚F–140˚F (-20˚C–60˚C)
Compliance & Certifications UL 867

CSA C22.2# 187

UL 2998

CARB

Troubleshooting

If the unit is not working, check the following:

  1. The supply fan is running and the green LED illuminates.
  2. Verify all power input connections to Sciaire Pro H110 are correct and tightened. Reconnect any loose wires as necessary.

Product Registration

To register your product visit https://dhlifelabs.com/product-registration/. The information provided in this manual is up to date at the time of printing. Any revisions to this document will supersede the content included. For the latest applicable version of this manual, visit https://dhlifelabs.com/help-support/ or scan the QR code on the left.DH-Lifelabs-Sciaire-Pro-H110-Carbon-Fiber-Brush-Output-Ionizer-FIG-3

Maintenance

  1. The Sciaire Pro H110 was designed for low maintenance. Inspect the ionizer brushes for dirt at least every six months. If the carbon fiber brushes are dirty, follow the cleaning instructions below:
    • Disconnect power.
    • Use compressed air or a small brush to remove any accumulated dust on the bristles of the brushes. Avoid brushes with metal bristles as these could damage the device.
    • Reconnect power.
  2. Inspect the LED light for dirt which can make the light hard to see. If dirt is present, wipe the LED with a small alcohol towelette.

Copyright © 2023 Dernier & Hamlyn Inc. All rights reserved.

  • Need Help?
  • 1-877-548-9722
  • 9 AM–6 PM, CST, Monday–Friday
  • Dernier & Hamlyn Inc.
  • 720 Northgate Parkway
  • Wheeling, IL 60090
  • The Sciaire Pro Air Ion Generator uses PlasmaShield™ Technology.
  • Dispose of used products according to local regulations.

Documents / Resources

DH Lifelabs Sciaire Pro H110 Carbon Fiber Brush Output Ionizer [pdf] Instruction Manual
H110-240GR, Sciaire Pro H110 Carbon Fiber Brush Output Ionizer, Sciaire Pro H110, Carbon Fiber Brush Output Ionizer, Fiber Brush Output Ionizer, Brush Output Ionizer, Output Ionizer, Ionizer

References

Leave a comment

Your email address will not be published. Required fields are marked *