HOLOPHANE-LOGO

HOLOPHANE HARP Series Discontinued MH Post Top

HOLOPHANE-HARP-Series-Discontinued-MH-Post-Top-PRODACT-IMG

Product Information

The Harp Series is a discontinued outdoor lighting fixture available in two versions: 3 x 4 tall tenon mount version and 2 threaded pipe mount version. The luminaire is designed for outdoor use and requires installation by a qualified professional.

Important Safety Instructions

  • Read and follow all instructions carefully before attempting to install or maintain the fixture.
  • All work must be done by qualified personnel.
  • Disconnect power from the fixture before installing or maintaining the fixture.
  • Failure to follow these warnings may result in death, injury, or significant property damage.

Alternate Information Sources

If you require additional information, contact the Holophane Field Service Department at:

  • P.O. Box 3004
  • Newark, OH 43058-3004
  • Phone: (866) 759-1577

Product Usage Instructions

The following instructions are for the installation and maintenance of the Harp Series fixture.

Product Installation

Tools and Materials Required

Description Use
1/8 hex wrench Mounting set screws
3/8 nutdriver or medium flat screwdriver Ballast assembly plate and wireway cover
Torque wrench N/A
7/16 nutdriver or socket Ballast assembly cover
1/4 nutdriver or medium flat screwdriver Ballast assembly plate

Fixture Installation

  1. Feed supply leads from the pole through the wireway hole.
  2. Place and level the luminaire on the pole. On units that mount to a 3O.D. X 4 tall tenon, alternately tighten the (6) set screws to 10-12 foot pounds. See Figure 1. On units that mount to a 2 threaded pipe, install the pipe nut (not supplied) used to secure the unit.
  3. Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked L1 (Line 1). G (Ground), and L2 (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal L2. Refer to Figure 2.
  4. Holding the ballast assembly/top cover in one hand, use the other hand to connect the male wiring harness connector to the female wiring harness connector. See Figure 2.
  5. Gently place ballast assembly into chamber of housing.
  6. Tighten (3) set screws on ballast assembly/top cover. See Figure 2.
  7. Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
  8. Install the proper lamp type. Tighten the lamp carefully but securely.
  9. Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
  10. Energize the luminaire. Check for proper operation.

Product Maintenance

Relamping and Cleaning

  1. Wipe off exterior dirt and debris.
  2. Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
  3. Remove lamp.
  4. Wipe out the refractor interior with a clean dry cloth.
  5. Install new lamp of correct wattage and type. Tighten the lamp carefully but securely.
  6. Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
  7. Energize the luminaire. Check for proper operation.

IMPORTANT SAFETY INSTRUCTIONS

WARNING – READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL.
WARNING – BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
WARNING – FOLLOW LAMP MANUFACTURER’S OPERATING AND MAINTENANCE INSTRUCTIONS. FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE.

INTRODUCTION

Product Description

  • The Harp luminaires have been designed to distribute specific patterns of light on the surface below. All optics have street side orientation embossed on the flange of the refractor.
  • The Harp luminaire is designed for easy maintenance.
  • The lamp can be easily accessed by loosening a screw and swinging down the refractor.
  • Electrical components are mounted on an easily removable ballast assembly plate.

Alternate Information Sources

  • Holophane
  • Field Service Department
  • P.O. Box 3004
  • Newark, OH 43058-3004 (866) 759-1577

INSTALLATION

Tools and Material Required

Table 1. Installation Tools and Materials

DESCRIPTION  USE

  • 1/8″ hex wrench Set screws (mounting)
  • 3/8″ nutdriver or medium Ballast assembly plate flat screwdriver and wireway cover Torque wrench Set screws
  • 7/16″ nutdriver or socket Ballast Assembly Cover
  • 1/4″ nutdriver or medium Ballast assembly Plate flat screwdriver

Fixture Installation

  1. Feed supply leads from the pole through the wireway hole
  2. Place and level the luminaire on the pole. On units that mount to a 3″O.D. X 4″ tall tenon, alternately tighten the (6) set screws to 10-12 foot pounds. See Figure 1. On units that mount to a 2″ threaded pipe, install the pipe nut (not supplied) used to secure the unit.2.2.3 Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked “L1” (Line 1). “G” (Ground), and “L2” (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal “L2”. Refer to Figure 2.HOLOPHANE-HARP-Series-Discontinued-MH-Post-Top-FIG-1
  3. Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked “L1” (Line 1). “G” (Ground), and “L2” (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal “L2”. Refer to Figure 2.
  4. Holding the ballast assembly/top cover in one hand, use the other hand to connect the male wiring harness connector to the female wiring harness connector. See Figure 2.
  5. Gently place ballast assembly into chamber of housing.
  6. Tighten (3) set screws on ballast assembly/top cover. See Figure 2.HOLOPHANE-HARP-Series-Discontinued-MH-Post-Top-FIG-2
  7. Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
    OPTICS ORIENTATION NOTES
    Some of the fixtures in this series are equipped with optical components that produce distributions of light that are not symmetric and are intended to be aimed by orienting the prismatic refractor a specific direction. The “Street Side” marking on the refractor should be pointed toward the street.
  8. Install the proper lamp type. Tighten the lamp carefully but securely.
  9. Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
  10. Energize the luminaire. Check for proper operation.

MAINTENANCE

Relamping and Cleaning

  1. Wipe off exterior dirt and debris.
  2. Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
  3. Remove lamp.
  4. Wipe out the refractor interior with a clean dry cloth.
  5. Install new lamp of correct wattage and type. Tighten the lamp carefully but securely.
  6. Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
  7. Energize the luminaire. Check for proper operation.

Replacement Ballast Assembly

  1. Loosen (3) set screws on ballast assembly/top cover. Refer to Figure 2.
  2. Pull up ballast assembly/top cover with one hand and use other hand to disconnect the male wiring harness connector.
  3. Flip assembly upside down, loosen the (3) keyway screws and turn ballast plate assembly clockwise to disengage.
  4. Unpack replacement ballast assembly. Check voltage leads.
  5. Place the top of the ballast assembly on the bottom of the top cover. Rotate ballast assembly counter-clockwise until the keyway screws engage. Tighten the (3) keyway screws.
  6. Flip ballast assembly/top cover 180 degrees, connect the male wiring harness connector to the female wiring harness connector and gently place assembly down into housing.
  7. Tighten (3) set screws.
  8. Energize the luminaire. Check for proper operation.

WARRANTY

LIMITED WARRANTY AND LIMITATION OF LIABILITY

The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide, and is available from your local Holophane sales representative.

Acuity Lighting Group, Inc

  • 214 Oakwood Ave., Newark, OH 43055
  • IM-136-B 4/03 ©2003 Acuity Lighting Group Inc.
  • Visit our web site at www.holophane.com

Documents / Resources

HOLOPHANE HARP Series Discontinued MH Post Top [pdf] Installation Guide
GR892, GR1074, HARP Series Discontinued MH Post Top, HARP Series, Discontinued MH Post Top, MH Post Top, Post Top, Top