500W Single Output with PFC Function
RSP-500 series
Dimension
L | W | H |
230 | 127 | 40.5 (1U) mm |
9.06 | 5 | 1.59 (1U) inch |
https://www.meanwell.com/Upload/PDF/Enclosed_Type_EN.pdf
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90.5%
- Forced air cooling by built-in DC fan (Note.5)
- Built-in remote ON-OFF control / remote sense
- Protections: Short circuit/Overload/Over voltage/Over temperature
* 3 years warranty
Applications
* Factory control or automation apparatus
* Test and measurement instrument
* Laser related machine
* Burn-in facility
* RF application
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Model Encoding/Order Information
SPECIFICATION
MODEL | RSP-500-3.3 | RSP-500-4 | RSP-500-5 | RSP-500-12 | RSP-500-15 | RSP-500-24 | RSP-500-27 | RSP-500-48 | ||
OUTPUT | DC VOLTAGE | 3.3V | 4V | 5V | 12V | 15V | 24V | 27V | 48V | |
RATED CURRENT | 90A | 90A | 90A | 41.7A | 33.4A | 21A | 18.6A | 10.5A | ||
CURRENT RANGE | 0 – 90A | 0 – 90A | 0 – 90A | 0 – 41.7A | 0 – 33.4A | 0 – 21A | 0 – 18.6A | 0 – 10.5A | ||
RATED POWER | 297W | 360W | 450W | 500.4W | 501W | 504W | 502.2W | 504W | ||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | ||
VOLTAGE ADJ. RANGE | 2.8 – 3.6V | 3.6 – 4.3V | 4.5 – 5.5V | 10 – 13.2V | 13.5 – 18V | 20 – 26.4V | 26 – 30V | 41 – 56V | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% | ||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
SETUP, RISE TIME | 1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load | |||||||||
HOLD UP TIME (Typ.) | 18ms/230VAC 14ms/115VAC at full load | |||||||||
INPUT | VOLTAGE RANGE Note.4 | 85 – 264VAC 120 – 370VDC | ||||||||
FREQUENCY RANGE | 47 – 63Hz | |||||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 81% | 183% | 84% | 188% | 188% | 189% | 190.% | 191.% | ||
AC CURRENT (Typ.) | 4.2Af115VAC 2.1 A/230VAC | 5.3A/115VAC 2.65 A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | 20A/115VAC 40A/230VAC | |||||||||
LEAKAGE CURRENT | <2mA/ 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 -130% rated output power | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.8 – 4.5V | 4.5 – 5.3V | 15.75 – 6.75V | 113.8 – 16.2V | 18.8 – 21.8V | 27.6 – 32.4V | 132.9 – 38.3V | 158.4 – 68V | ||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
FUNCTION | REMOTE CONTROL | POWER ON:open or 0-0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100 POWER OFF: 4-10VDC between RC+(Pin 4)&RC-(Pin3) on CN100 | ||||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V | |||||||||
FAN CONTROL (Typ.) | RTH250°C± 10°C Fan on ; RTH240°C±10°C Fan off (Fan always on for 3.3-SV,Fan ON/OFF control for 12-48V) | |||||||||
ENVIRONMENT | WORKING TEMP. | -30 – +70°C (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 – 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 – +85°C, 10 – 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/°C (0 – 50°C) | |||||||||
VIBRATION | 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note.4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 , CCC GB4943.1 . BSMI CNS14336-1approved | ||||||||
WITHSTAND VOLTAGE | I/P-0/P:3KVAC IIP-FG:2KVAC 0/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-0/P, I/P-FG, 0/P-FG:100/1 Ohms / 500VDC / 25°C / 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS ENIEN61000-3-2,-3, EAC TP TC 020,G8/T 9254, CNS13438 Class B | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 1372.4K hrs min. Telcordia SR-332 (Bellcore) ; 187.9K hrs min. MIL-HDBK-217F (25°C) | ||||||||
DIMENSION | 230*127*40.5mm (L’W*H) | |||||||||
PACKING | 1.3Kg; 9pcs112.7Kg10.7CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance. line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Fan always on for 3.3-5V.Fan ON/OFF control for 1 2-48V. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 7. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft). ,%:.: Product Liability Disclaimer : For detailed information. please refer to https://www.meanwell.com/serviceDisclaimeraspx |
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Function Description of CN100
Pin No. | Function | Description |
1 | -S | Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V. |
2 | +S | Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V. |
3 | RC- | Return for RC+ signal input. |
4 | RC+ | Turns the output on and off by electrical or dry contact between pin 4 ( RC+) and pin 3 (RC-). 0-0.8VDC or open: Power ON, 4-10VDC: Power OFF. |
Function Manual
- Remote Control
The PSU can be turned ON/OFF by using the “Remote Control” function.Between RC-(pin3) and RC+(pin4) on CN100 PSU Status SW OFF (0 ~ 0.8VDC) or open ON SW ON (4 ~ 10V) OFF - Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.3V
Documents / Resources
MEAN WELL RSP-500 Series Switching Power Supply Enclosed Single Output [pdf] Owner's Manual RSP-500-3.3, RSP-500-4, RSP-500-5, RSP-500-12, RSP-500-15, RSP-500-24, RSP-500-27, RSP-500 Series Switching Power Supply Enclosed Single Output, RSP-500 Series, Switching Power Supply Enclosed Single Output, Power Supply Enclosed Single Output, Supply Enclosed Single Output, Enclosed Single Output, Single Output, Output |