Technical Data & Features

Model No. HC-12P/HC-18P/HC-22P/HC-24P3,HC-24G2
Brand BBINGI
Capacity(L) 12.8/18/22/24
Dimension(mm) 440x330x285/440x330x340/

440x330x380/580x32Sx345

Net Weight(KG) 8.5/9/9.5/12
Refrigeration Compressor Cooling
Performance Cooling
Rated Voltage(V) DC12V/DC24\/,(Adapter 110-240V)
AveragePcJ.NerfY,/j Cooling:45W/45W/50W/50W
Temp Setting ‘C -18~15’C
Usage Inside Car; House (by AC Adaptor)
Working Temp’C -5~35’C

 

 

  • Wrth High Efficiency DC compressor,Reliable & Fast Cooling
  • Good Insulation By ECO C5H10o
  • Smart Protection System on Car Battery

Accessory List

  • Standard accessory: DC line
  • AC adapter is required for household use

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-1

Notice or Daily Use

  • Do not store explosives, such as spray, in the refrigerator.
  • This appliance is intended to be used in house or car, and similar applications:
    • taff kitchen areas in shops, offices and other working environments;
    • arm houses and by clients in hotels, motels and other residential type environments;
    • ed and breakfast type environments;
    • catering and similar non-retail applications;
    • suitable for camping use, the appliance shall not be exposed to rain.
  • If no use for long time, Please cut off Power connecting first. then clean refrigerator cabinet & body.
  • At all times, it is necessary to ensure that the power voltage connected to the car refrigerator is correct.
  • The label & next to the ventilation grille is a foam material fireproof label, please stay away from open flames.
  • Do not discard discarded refrigerators at will. They should be recycled and disposed of by a professional company.

Power Connecting

Usage Instructions
 

 

 

Inside Car

1.Connect DC cable to refrigerator first
2.Then Connect DC cable to Car Battery terminal
3.Press ”  ” button, Refrigerator starts working
 

 

 

Indoor Use

1.Choose BINGI AC Adaptor
2.Connect AC Adaptor to refrigerator
3.Connect Adaptor to Power supply from home

 

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-2

Control Panel Setting

Panel Set
HC-12P/HC-18P/HC-22P

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-3

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-4

Buttons & Setting

Button Set Description
 

On/Off

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-9

 

On After power connected, screen is black, please Press

Screen lights, compressor worl<s and standby

Off Press” BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-9 “by 5 seconds, Screen keeps black,

refrigerator switches off

Mode

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-5

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-8

automatic Lock of Screen Lock If no further operation 20 seconds after switching on,all buttons, except BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-5,will be locked turn black
 

Unlock

Press BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-5 by 3 seconds,all buttons will be unlocked

as for                  operation.

 

“+”

 

Temp Up

Temp increase 1’C by one Press, and continue to increase if Press + by 2 seconds, Highest Temp set is 55′(
BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-7  

Temp Down

Temp decrease 1’C by one press and continues to decrease if Button “-” is Pressed by 2 seconds, lowedecreasesst temp set is

-18′(.

REMARK

  1. BINGI Refrigerator has auto-restart function, which will restore all setting automatical
  2. Refrigerator compressor will start working 3 min after Pressing “on” button, which is safety  Protection

Trouble Shooting

  • Out of order
    • To Ched< power mnnection
    • To Press On/OFF button on Screen
    • To Ensure refrigerator exhaust heating easily
    • To check safety device
  •  Abnonnal noise
    • Refrigerator on uneven place
    • compressor noise is bigger when switching on, it will reduce soon
  • Noise similar like water flow
    • it is normal as refrigerant is circling.
  • Poor Cooling
    • To check door closed well or not
    • To check door insulation in good condition or not
    • To remove anything that stop mmpressor heat-exhausting
    • To check mode selection
  • Water condensation on refrigerator
    • It happens when air humidity is high and temperature of refrigerator body is low, please clean the moisture in time
Code Problem Description Remarks
P01 Compressor PCB temperature is too high  
P02 Sensor problem Sensor short circuit or open circuit.
P03 Fan motor problem Fan open circuit or malfunction.
P04 Voltage not stable 12V: It means Supply voltages9.6V or 217; 24V: It means Supply voltages21.3V or 231.SV
POS Over-rated current  
P06 Compressor non-start Too hot, or too low voltage.
P07 Compressor PCB problem Fan motor out of order

After sale Service

  • One year warranty
  • Damages or problems Listed below are not within warranty. —Deliberate damage
    • Caused by Force majeure
    • Caused by unproper operation
    • Repair or breakdown by unauthorized person.

Power Connecting

Attached: Wiring Connections

BINGI-‎HC-18P1-Compressor-Cooler-Small-Compact-Auto-Refrigerator-FIG-5

Guangdong BINGI Electrical Appliances Co., Ltd.

  • ADD: Building 29, Industrial Park of SHUN DE WISDOM CREAT WEALTH, Xingtan Town,
  • Shunde District, Foshan City, Guangdong Province, CHINA
  • Tel: 0757-26610879
  • E-mail: johnny@eateron.com

Documents / Resources

BINGI ‎HC-18P1 Compressor Cooler Small Compact Auto Refrigerator [pdf] User Manual
HC-18P1 Compressor Cooler Small Compact Auto Refrigerator, HC-18P1, Compressor Cooler Small Compact Auto Refrigerator, Cooler Small Compact Auto Refrigerator, Small Compact Auto Refrigerator, Compact Auto Refrigerator, Auto Refrigerator, Refrigerator

References

Leave a comment

Your email address will not be published. Required fields are marked *