Koolatron-logo

Koolatron P65 Thermoelectric Cooler Warmer

Koolatron-P6--Thermoelectric-Coole-Warmer-product

Specifications

  • Product: 12V Thermoelectric Cooler/Warmer
  • Model Numbers: P65, P9, P75, P20, P85, P27, P95
  • Power Pack: Power Adapter (included)
  • 12V Power Cord: Cordon d’alimentation 12V (included)
  • Warranty: 1 year from the date of retail purchase

ACCESSORIES

For prices and availability please call: 1-800-265-8456

Koolatron-P6--Thermoelectric-Coole-Warmer-01

Power Pack
Power Adapter Adaptateur de courant

12V Power Cord
Koolatron-P6--Thermoelectric-Coole-Warmer-03

Battery Saver Koolatron-P6--Thermoelectric-Coole-Warmer-04

WARRANTY

  • Koolatron Corporation warrants that this product will be free from defects in materials or workmanship under normal household use for a period of 1 year from the date of retail purchase. During this time, defective products will be repaired or replaced at the discretion of the retailer and/or Koolatron Corporation.
  • This warranty covers normal household usage and does not cover damage which occurs in shipment or results from accident, misuse or abuse, unauthorized repair or alteration, improper maintenance, commercial use, or use with a voltage converter or aftermarket accessories.
  • A Koolatron Master Service Centre must perform all warranty work.

WARRANTY AND SERVICE PROCEDURE

  • Keep your original, dated, sales receipt with this manual. If this product proves to be defective within the warranty period, please contact Koolatron Corporation at 1-800-265-8456 (North America) or email service@koolatron.com for assistance.
  • Register online at www.koolatron.com and add another 6 months of warranty protection.

FEATURES

  • The unit employs thermoelectric technology using the latest Peltier devices.
  • Environmentally friendly. Does not contain any CFC’s or polluting coolants.
  • High performance with low power draw. Cools to approximately 22°C / 40°F below ambient temp. Heats to approximately 135°F / 57°C inside.
  • Reliable and virtually wear free. Apart from the fan, the thermoelectric cooling unit does not have any moving parts.
  • Optional Power Adapter permits use of cooler in your house or hotel, from any 110/120 volt AC wall outlet.

OPERATING INSTRUCTIONS

  • Just plug your cooler into the 12 volt receptacle in your vehicle. The current consumed is about 4.5 amps, except P9, which consumes 3.5 amps. When your vehicle is running and the electrical system is operating properly, your cooler will operate continuously without discharging the battery. When the battery is not being charged, the cooler should not be operated for more than 4 hours.
  • The cooler can be operated continuously from a 110/120 volt AC wall outlet using the optional Kolton Power Adapter.
  • For best results, precool your unit and the food and beverages before placing them in your cooler. If the cooler is loaded with warm material, it will require at least 12 hours to cool the contents.
  • The cooler can be operated in the heating mode, by reversing the polarity of the power supplied to the cooler. This can easily be done by gently pulling out the power cord from the cord connector, reversing the bi-pin plug and pushing it back in.

NOTE

  • When the arrow is aligned with the red dot the unit is in heat mode.
  • When the arrow is aligned with the blue dot the unit is in cooling mode.
  • Do not operate your cooler in the heating mode for longer than 45 minutes continuously. Excessive temperatures in the unit may cause bulging of the liner.

Koolatron-P6--Thermoelectric-Coole-Warmer-02

POWER CORD CONNECTOR
To change between HEATING and COOLING modes, unplug,

MAINTENANCE

  • Keep cords and cigarette lighter sockets clean at all times. Dirt particles in the socket or the plug may affect performance.
  • The motor, fan and control panel vents should be cleaned periodically. While the unit is unplugged, clean the fan blades and motor shaft using a paint brush or other soft bristled brush. Remove all hair, dirt, or dust that may have accumulated.
  • To clean, wipe the inside with a warm damp cloth or sponge. Do not use harsh or abrasive cleaners. A mild soap should be sufficient, but if stains or odors remain, household bleach or baking soda may be added to the washing solution. Keep the lid open for several hours after cleaning to allow the interior to thoroughly dry and to prevent odors from forming in the cooler.
  • For long periods of storage, a small container of baking soda or charcoal, placed inside, will eliminate objectionable odors.

PRECAUTIONS

  • The cooler is designed to operate on 12 volts direct current only. Do not attempt to connect the cooler directly to 110/120 volt AC wall socket without using the optional Koolatron Power Adapter.
  • Do not use the cooler with any other AC adapter device other than the optional Koolatron Power Adapter. Failure to do so may invalidate warranty and pose a hazard.
  • Do not operate the cooler in direct sunlight or in hot enclosed areas such as automobile trunks. The cooler generates heat and must have free air circulation to perform properly.
  • Do not block the ventilation area of the control panel. Free flow of air is necessary for effective heat transfer. Regularly check the panel for dirty or clogged vents.
  • The aluminum fins in the cooler will be hot rotate 180° and relog. when used in the heating mode. Exercise care to avoid injury. The aluminum fins in the control panel area will be hot after extended before removing panel.
  • For safe handling of food, the cooler should not be used as a food warmer for extended periods of time.
  • Ensure that the cigarette lighter socket is clean and safeguarded by a correctly fused circuit.
  • Push the plug firmly into the lighter socket to ensure good contact.

WARNING! This product contains chemicals known to the State of California to cause cancer, and birth defects or other reproductive harm. www.P65Warnings.ca.gov