HYPERLITE - LOGORELIABLE SOLID BRIGHTHYPERLITE Hive Series LED Work Light

Hive Series LED Work Light

HYPERLITE Hive Series LED Work Light - LIGHT

FEATURES

– 4KV Surge Protection, lamp can bear sudden high voltage.
– 50,000hours life span with 5 years warranty.
– Painted metal guard for impact protection.
– 10ft 16AWG cord with plug suitable to huge construction area. HYPERLITE Hive Series LED Work Light - WARRANTY

SPECIFICATIONS

Performance Data BWRL-60W-B WRL-100W-B BWRL-120W-B
General Lumens 7500 Im 12500Im 15000 Im
Efficacy 125 Im/W
CCT 5000K
CRI >80
Life span >50,000 hours
Electrical Power 60W 100W 120W
Input voltage AC 120V
Surge protection 4KV surge protector for optional
Power factor >0.9
Options Operating temperature -40°F to 113°F
Listings UL, cUL
Warranty 5 Years

HYPERLITE Hive Series LED Work Light - PACKAGE

PACKAGING INFORMATION

Model  Wattage  Qty Net Weight Gross Weight CTN Size 
BWRL-60W-B 60w 1 42±1lbs 5.0±1lbs 7.7″*7.7″*12.9″
BWRL-100W-B 100W 1 5.0±1lbs 5.8±1lbs 7.7″*7.7″*13.5″
BWRL-120W-B 120W 1 5.3±1lbs 6.2±1lbs 7.7″*7.7″*15.7″

INSTALLATION

– Place the work light up to the hanging hardware, push the gate of the carabiner clip against the hanging hardware until it opens (Pic 1).
– Captures the hardware (Pie 2) The installation is now completed. HYPERLITE Hive Series LED Work Light - INSTALL

CONNECTION

Hidden & built-in connector design. Customer can choose to connect several work lights in series or not.
Suitable to damp location. HYPERLITE Hive Series LED Work Light - CONNECTION– Linking Additional Units
Install each additional unit as in STEP 1. When adding units, turn cage light off prior to adding the additional units.
Max 7x120W can be linked on one string of lights and must NOT EXCEED 10A. Open the outlet access door in order to gain access to the grounded outlet (Pic3). Plug each additional light into the preceding unit (Pic4). Lock each plug in place by closing the locking buckle onto the plug (Pic. 5-6). Repeat as necessary.

Wattage UL Current@120V Link-able Qtys
120W 1.296 7PCS
100W 1.08 9PCS
60W 0.65 15PCS

HYPERLITE Hive Series LED Work Light - CONNECTION 2LED Work Light
(Hive Series)
UL CERTIFICATION
Certificate Number: E503681
Report Reference: E503681
Issue Date: 2018-DECEMBER-31

HYPERLITE Hive Series LED Work Light - WARRANTY 1Additional Information:
See the UL Online Certifications Directory at www.ul.com/database for additional information.
A Only those products bearing the UL Certification Mark should be considered as being covered by UL’s Certification and Follow-Up Service.
A Look for the UL Certification Mark on the product. HYPERLITE Hive Series LED Work Light - PARTSATTENTION
BEFORE YOU INSTALL
Read these instructions completely and carefully.
BLAUPUNKT MS46BT Bluetooth CD-MP3 player with FM and USB - icon 3 WARNING
RISK OF ELECTRIC SHOCK

  • Turn power off before inspection, installation or removal.
  • Properly ground electrical enclosure
  • Follow all NEC and local codes.
  • Use only UL or IEC approved wire for input/output connections.

Save These Instructions
Use only in the manner intended by the manufacturer If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
HYPERLITE Hive Series LED Work Light - ICON 1 Electrical Requirements
The LED driver must be supplied with 120VAC, 60Hz per product label and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker.
HYPERLITE Hive Series LED Work Light - ICON 2 Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. HYPERLITE Hive Series LED Work Light - CABLEPlease check that the plug is in good condition.
Install the lamp and plug it into the socket.
Then you can test the light fixture.

APPLICATION

Task lighting, commercial lighting, work areas etc. HYPERLITE Hive Series LED Work Light - APPLICATION

FOOTCANDLE LIGHT GUIDE

Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined the ii luminance on a one square foot surface from a uniform source of light. The Illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy-efficiency.

Buildinc Area &Task Average
Maintained
Footcandles
(Horizontal) (FC)
Range of
Maintained
Footcandles
(Horizontal) (FC)
Average
Maintained
Footcandles
(Vertical) (FC)
Range of
Maintained
Footcandles
(Vertical) (FC)
Comments

WAREHOUSING & STORAGE

Bulky Items—Large Labels 10 5
Small Items—Small Labels 30 15
Cold Storage 30-40 10-30 10 5-15
Open Warehouse 30-40 10-30
Warehouse w/Aisles 30-40 10-30 10 5-15

COMMERCIAL OFFICE

Open Office 40 30-50 @30″ Above Finished Floor (AFF)
Private Office 40 30-50 @30″ AFF
Conference Room 30 Matte surface reflectance for the table 40% recommended
Restroom 18 75-30
Lunch & Break Room 15 5-20

EDUCATIONAL (SCHOOLS)

Classroom 40 30-50 @30″ AFF
Gymnasium
Class I (Pro or Div. 1 College) 125 30
Class II (Div. 2 or 3 College) 80 20
Class III (High School) 50 150
Class IV (Elementary) 30 100
Auditorium 75 3-10 5 2 5-10
Corridor 25 10-40

TELEFUNKEN TF-1709 Radio with Alarm - up button This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.

Building Area &Task Average
Maintained
Footcandles
(Horizontal) (FC)
Range of
Maintained
Footcandles
(Horizontal) (FC)
Average
Maintained
Footcandles
(Vertical) (FC)
Range of
Maintained
Footcandles
(Vertical) (FC)
Comments

INDUSTRIAL/MANUFACTURING

Assembly
Simple (Large Item) 30 15 15-60
Difficult (fine) 100 10-30 10 50-200
Component Manufacturing
Large 30 10-30 30 15-60
Medium 70-80 25-100 50 25-100

EXTERIOR

Parking (Covered) 5 1FC min,10:1 Max to Min Uniformity
Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban) 1.5 75-3 0.8 0.4-1.6
Lighting Zone 2 (suburban) 1 0.5-2 0.6 0.3-1.2
Gas Station Canopy 12.5 10-15
Safety (Building Exterior) 1 0.5-2 If security is an issue-raise average level to 3

RETAIL

General Retail (Ambient) 50
Department Store 40 20 – 80 15 7.5-30
Perimeter 75 35-150
Accent Lighting (Displays) 3-10 times greater than ambient light levels

AUTOMOTIVE

Showroom 70-80 25-100 10 7.5-30
Service Area 50 25-10 30 15-30
Sales Lot (Exterior)
Lighting Zone 3 (Urban) 20 10-40 20 10-40
Lighting Zone 2 (Suburban) 15 7.5-30 15 7.5-30

GROCERY

Circulation 20 10-40 7.5 3.5-15
General Retail 70-80 25-100 20 10-40
Perimeter 50 25-100

BANKING

ATM 20 10-40 15 Vertical at face of ATM

NOTES:

  • This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition.
    It is highly recommended that all lighting professionals refer to the full I ES guide when specifying lighting projects
  • At least half of users are in the 25-65 age range.
  • Horizontal-horizontal plane that average maintained foot-candles are measured.
  • Vertical-vertical plane the average maintained foot-candles are measured
  • It is the responsibility of the to determine and provide appropriate lighting levels for each space.

LED High Bay Light HYPERLITE Hive Series LED Work Light - LIGHT 1LED Flood Light
LED Grow Light HYPERLITE Hive Series LED Work Light - LIGHT 2Area Light & Canopy Garage Light
LED Vapor Tight Light HYPERLITE Hive Series LED Work Light - LIGHT 3LED Wall Pack Light
Temporary Work Light HYPERLITE Hive Series LED Work Light - LIGHT 4More products..

HYPERLITE - LOGOwww.hi-hyperlite.com
Web: www.hi-typerlite.com
Email: service01@hi-hyperlite.com
Tel: +1(855) 688 7879HYPERLITE Hive Series LED Work Light - ICON 3

Documents / Resources

HYPERLITE Hive Series LED Work Light [pdf] Instructions
Hive Series LED Work Light, Hive Series, LED Work Light, Work Light, Light

References

Leave a comment

Your email address will not be published. Required fields are marked *