Product Usage Instructions

1. Safety Instructions

It is important to follow all safety instructions provided with the XL Display Stand to prevent personal injury, damage to the product, or voiding of the warranty.

  • Dangerous Voltage Warning: Be aware of hazardous voltage within the product’s enclosure that may pose a risk of electric shock.
  • Grounding: Connect the device to a properly grounded outlet to avoid electric shock. Do not defeat the safety purpose of the plug.
  • Avoid Water Exposure: Keep the apparatus away from dripping or splashing liquids.

2. Installation

Ensure that the XL Display Stand is loaded according to specifications. Follow the provided instructions for mounting single or dual displays securely.

3. Power Requirements

Make sure the device is connected to a 120V outlet. Do not use plug adapters that defeat the ground pin of the AC plug.

4. Weight Ratings

The XL Display Stand is designed to support displays of up to 100 inches in size. Refer to the weight ratings for specific Chief Fusion Fixed Display Mount configurations.

FAQs

  • Q: Can I use the XL Display Stand for both single and dual displays?
    • A: Yes, the XL Display Stand is compatible with both single and dual displays.
  • Q: What is the maximum display size supported by the XL Display Stand?
    • A: The XL Display Stand can accommodate displays of up to 100 inches in size.

NOTE: Free standing and floor-to-wall models shown.
XL Display Stand for Single and Dual Displays
Instruction Sheet
100-00087 Rev B
22 PAP

IMPORTANT SAFETY INSTRUCTIONS

· Read these instructions. · Heed all warnings. · Keep these instructions. · Follow all instructions.

· Clean only with dry cloth. · Only use attachments/accessories specified by the manufacturer.

DANGER HAZARDOUS VOLTAGE: The lightning flash with the arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
WARNING: A warning alerts you to a situation that could result in serious personal injury or death.
CAUTION: A caution alerts you to a situation that may result in minor personal injury or damage to the product and/or property.
WARNING: Middle Atlantic Products, electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical products may present a possible shock or fire hazard if improperly installed or used. Electrical products may bear the mark of a Nationally Recognized Testing Laboratory (NRTL) and should be installed in conformance with current local and/or the National Electrical Code.
WARNING: Failure to read, understand and follow the following information can result in serious personal injury, damage to the equipment or voiding of the warranty. It is the responsibility of the Installer/User to ensure that this product is loaded according to specifications.
WARNING: Risk of Electric Shock: Connect the device to a properly grounded outlet only. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
WARNING: The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus.
WARNING: To reduce the risk of burns, fire, electric shock, or injury to persons: · Unplug from outlet before putting on or taking off parts. · Close supervision is necessary when this device is used by, or near children, invalids, or disabled persons. · Use this device only for its intended use as described in these instructions. Do not use attachments not recommended by the
manufacturer. · Never operate the device if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or
dropped into water. Return the device to a service center for examination and repair. · Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where
they exit from the apparatus. · Keep the cord away from heated surfaces. · Never drop or insert any object into any opening. · Do not use outdoors. · Do not operate where aerosol (spray) products are being used or where oxygen is being administered. · To disconnect, turn all controls to the off position, then remove plug from outlet.

CAUTION: Do not plug into another relocatable power tap

CAUTION: Do not plug into another relocatable power tap.
CAUTION: A caution alerts you to a situation that may result in minor personal injury or damage to the product and/or property.

Page 3

IMPORTANT SAFETY INSTRUCTIONS – EN (CONTINUED)
Safety Instructions: Rack Mount Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuit might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing: Reliable earthing of rack-mounting equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). Disconnect Device (Pluggable Equipment): The socket-outlet shall be installed near the equipment and shall be easily accessible. When using electrical products, basic precautions should always be followed, including the following: · Read and follow all instructions before using. · There are no user-serviceable components within this device. Removal of the cover from this device may present a shock hazard, and
void the warranty. · The mains plug is used as your disconnect device. This device shall remain readily operable. · Unplug this apparatus during lightning storms or when unused for long periods of time. · Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device
does not exceed that which is listed in the specifications section of this manual. · Ensure this device is connected to a properly grounded AC power source. Ensure the device is plugged into a source providing the
required 120V. Do not use a plug adapter that defeats the ground pin of the AC plug.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) DIRECTIVE
Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste, according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection center licensed for the recycling of waste electrical and electronic equipment (EEE). The mishandling of of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information about where you can take your waste equipment for recycling, please contact your local city office or your household waste collection service.

WEIGHT RATINGS

Item
Chief Fusion Fixed Display Mount Attached to the Forum Collaboration Suite Display Stand (Free Standing or Floor-to-Wall)
Display Stand’s Bottom Rackmount Storage Display Stand’s Top Small Device Storage Single Display Size of up to 100″
Double Display Size of up to 75″

Weight Rating
150 lbs. (68 kg) Maximum Total Rated Load NOTE: The combined maximum total rated load of the mount installed on the stand must not exceed the total rated load indicated. This includes the mounting of any additional camera, soundbar/audio, and AV accessories on the stand or mount.
50 lbs. (23 kg) Maximum Total Rated Load Per Bay
30 lbs. (14 kg) Maximum Total Rated Load
150 lbs. (68 kg) Maximum Total Rated Load Per Display NOTE: For Jupiter 105″ and Jupiter 81″ displays only, the maximum total rated load per display is 225 lbs. (102 kg).
300 lbs. (136 kg) Maximum Total Rated Load Per Display

WARNING: This product is intended for use only with the products and maximum weights indicated. Use with other products or products heavier than the maximum weights indicated may result in instability causing possible injury. Total equipment weight must not exceed the amounts indicated on the previous table. ADVERTENCIA: Este producto está destinado a ser utilizado solo con los productos y pesos máximos indicados. El uso con otros productos o productos más pesados que el peso máximo indicado puede causar inestabilidad que puede causar lesiones. El peso total del equipo no deberá superar las cantidades indicadas en el cuadro anterior. AVERTISSEMENT: Ce produit est destiné à être utilisé uniquement avec les produits et les poids maximum indiqués. L’utilisation avec d’autres produits ou produits plus lourds que le poids maximum indiqué peut entraîner une instabilité pouvant causer des blessures. Le poids total de l’équipement ne doit pas dépasser les quantités indiquées dans le tableau précédent.

SUPPLIED COMPONENTS AND HARDWARE

If any pieces are missing or damaged, please report it immediately to Technical Support at av.support@legrand.com or (866) 977-3901.

(2x) CHIEF GRADE 5 TOGGLER KIT (Model Number: FCAT1)
NOTE: Floor-to-Wall Display Stand Models Only

(4x) SNAPTOGGLE®
Anchor B

(4x) ¼”-20 x 2½” Hex Head Bolt
C

(4x) ¼”-20 Washer
D

Display Stand
NOTE: Free Standing and Floor-to-Wall models, respectively.
A
FOR FREE STANDING DISPLAY STAND ONLY

10″ Lever LockTM Plate
NOTE: Pre-Installed Inside Display Stand
E

(2x) Securing
Rivet F

(6x)
” Dome Plug
NOTE: If Free-Standing display stand is purchased.
G

:
Rear Door Keys
Spare Set Part Number (500-00828)
H

Side Door Keys
Spare Set Part Number: (500-01173)
J

(20x) Washer
K

Page 9

SUPPLIED COMPONENTS AND HARDWARE (CONTINUED)

56-65″

Dual Display Sizes 50-55″ 56-65″ 66-75″
Single Display Sizes 70-75″ 76-85″ 86-100″
Jupiter 81″ ® Jupiter 105″ ®

Shroud Pairs
NOTE: Left shroud is shown for a 56-65″ Dual Display.
L

Shroud Interface Bracket Pair
NOTE: Only the 75″ dual display shroud kit contains (2x) bracket pairs.
M

Rear Shroud Bracket Pair
N

Horizontal Extrusion P

Single or Dual Display

Qty.

Single

1 Extrusion

Dual

2 Extrusions

Bridge Panels
NOTE: Included in shroud kit.
R

(8x)
12 x ”
Phillips Head Sheet Metal Screw S

Extrusion End Cap Pair T

(4x) ¼-20 x ½” Pan Head Phillips Thread Tapping End Cap Screws
U

(4x) 5/16″-18 Hex Nut
V

CONNECTING BRACKET KIT (FOR DUAL DISPLAY STAND ONLY, IF PURCHASED) (Model Number: FMSHC1)

NOTE: Quantity listed per hardware bag.

Connector Plate X-A

(6x) 10-24 x 1-½” Flat Head Cap
Screw X-B

(8x)
5/16 x ”
Button Head Cap Screw
X-C

(2x) Tie Bar
X-D

Adapter Bracket Pair
NOTE: For Jupiter 105″ displays only.
W
(18x)
¼”-20
Flange Nut Y

Connect Bracket
X-E

(8x) 5/16″ Split Washer X-F

(8x) Friction Washer
X-G

3/16″ Hex Key
X-H
Page 10


Hex Key
X-J

SUPPLIED COMPONENTS AND HARDWARE (CONTINUED)

(8x) 5/16-18 x 1″ Machine Screw
AB

Horizontal Extrusion Bracket Pair AA

Display Interface Pair Z

Single or Dual Display

Qty.

Single Display

1 Pair

Dual Display

2 Pairs

Number of Extrusions 1 Extrusion 2 Extrusions

Qty. (L and R) 2 Brackets (1 of ea.) 4 Brackets (2 of ea.)

(8x) 5/16″-18 Flange Nut
AC

DISPLAY INTERFACE PAIR HARDWARE

NOTE: Two sets of the following interface hardware (9900-002248) are provided for dual display installations.

(4x) M4 x 12mm Pan Head Screw
IP-A

(4x) M4 x 20mm Pan Head Screw
IP-A

(4x) M4 x 25mm Pan Head Screw
IP-A

(4x) M5 x 12mm Pan Head Screw
IP-A

(4x) M5 x 20mm Pan Head Screw
IP-A

(4x) M5 x 25mm Pan Head Screw
IP-A

(4x) M6 x 12mm Pan Head Screw
IP-G

(4x) M6 x 20mm Pan Head Screw
IP-A

(4x) M6 x 25mm Pan Head Screw
IP-A

(4x) M8 x 12mm Pan Head Screw
IP-A

(4x) M8 x 20mm Pan Head Screw
IP-A

(4x) M8 x 30mm Pan Head Screw
IP-A

(8x) Spacer
IP-B

(4x) Washer
IP-C

NOTE: · To order more hardware, contact support at av.support@legrand.com or (866) 977-3901. · Additional hardware is included that may not be required for your installation.

REQUIRED TOOLS

· Protective Eyewear · Pencil · Electric Drill · ½” Drill Bit · 3/32″ Drill Bit · Level · Socket wrench · 5/16″ Socket

· 7/16″ Socket · ½” Socket · #2 Philips Screwdriver · #2 Philips Bit · Mini Ratchet · Stubby #2 Phillips
Screwdriver

WARNING: Use tools with caution and follow all necessary safety protocols. ADVERTENCIA: Utilice las herramientas con precaución y siga todos los protocolos de seguridad necesarios. AVERTISSEMENT: Utiliser des outils avec prudence et suivre tous les protocoles de sécurité nécessaires.

Page 11

INTRODUCTION

NOTE: · Please take the time to carefully unpack and inspect all of the products you ordered and save this
instruction sheet for future use. · Maintenance and care information is provided in Care and Cleaning of Products (I-00788) and
Unpacking and Handling Precautions (I-00787) for your convenience. · All documents may be accessed at www.legrandav.com.
Your ForumTM collaboration suite configuration may include a free-standing XL display stand, a floor-to-wall XL display stand, and/or a table equipped with optional Wiremold ModPowerTM modular power units (table and ModPower units sold separately).
Use the topics in this instruction sheet in order of appearance to attach the floor-to-wall XL display stand to your wall (if applicable), the configuration of brackets and panels, and attaching your display(s) (not provided) to your display stand.
If you purchased a ForumTM Collaboration Suite Display Stand for Single Displays (100-00066) or a ForumTM Collaboration Suite Table Option (100-00086), please refer to those respective instuction sheets provided with your product or download them anytime from our website.
For more information, refer to the following ForumTM Collaboration Suite product page at www.legradav.com:
https://www.legrandav.com/Products/Technical_Furniture/Collaboration/Forum_Collaboration_Suite

REMOVING THE PANELS FROM YOUR DISPLAY STAND
1. Carefully tug at the magnetic sides of the front panels to remove from the display stand frame (A) and set aside for re-installation. (FIGURE A)
2. Carefully lift up the side panel to unhook it from the display stand frame and set aside for re-installation.
A

NOTE: Lift up side panel to unhook it from the display stand frame.
Side Panels
Front Panels

FIGURE B

Rear Panels

A
FIGURE A

FOR FREE-STANDING MODELS ONLY: Repeat step 1 to remove rear panels from your display stand. (FIGURE B)
Page 12

ATTACHING THE DISPLAY STAND TO YOUR WALL (FLOOR-TO-WALL MODELS ONLY)
WARNING: This procedure requires at least one additional person. ADVERTENCIA: Este procedimiento requiere al menos una persona adicional. AVERTISSEMENT: Cette procédure nécessite au moins une personne supplémentaire.
1. Carefully team lift your display stand (A) and place it on its feet against your desired mounting wall.
WARNING: The display stand must always bear its weight on its feet when wall mounted. ADVERTENCIA: El soporte de visualización siempre debe soportar su peso en los pies cuando se monta en la pared. AVERTISSEMENT: Le présentoir doit toujours supporter son poids sur ses pieds lorsqu’il est fixé au mur.

NOTE: Consider power receptacles on the wall and power requirements when positioning your display stand.
2. Use a pencil to draw horizontal lines on your wall from the center of the top and bottom keyhole slots (shaded) of the display stand. (FIGURE C)

3. With the display stand still on the wall, mark your desired keyhole slot drilling locations along top and bottom keyhole slot lines (drawn during previous step) as shown.

NOTE: Draw lines as close to the middle of the keyhole slot as possible.

4. Carefully team lift your display stand away from the wall.

NOTE:

· If securing to a wall with steel or wood studs, use a

pencil and a stud finder to align your keyhole slot

drilling locations along top and bottom keyhole slot

lines (drawn during step 2) to hit the studs. · If you are not securing your display stand into steel

FIGURE C

studs using the provided SNAPTOGGLE® anchors (B), and instead are going into wood studs, you

must provide your own lag bolt hardware that meets the appropriate weight ratings specified in “Weight

Ratings” on page 9.

· If you are not securing your display stand into cinderblocks using the provided SNAPTOGGLE anchors

(B), and instead are going into a solid concrete wall, you must also provide your own concrete anchor

hardware meeting the appropriate weight ratings specified.

WARNING: Customer-provided mounting hardware must be used on all four keyhole slot locations when securing the display stand to any wall type and the unit must be set on the ground. ADVERTENCIA: El material de montaje proporcionado por el cliente debe utilizarse en las cuatro ranuras de los orificios de bloqueo al fijar el soporte de pantalla a cualquier tipo de pared y la unidad debe colocarse en el suelo. AVERTISSEMENT: Le matériel de montage fourni par le client doit être utilisé sur les quatre emplacements des trous de serrure lors de la fixation du support d’affichage à tout type de mur et l’unité doit être placée sur le sol.
Page 13

ATTACHING THE DISPLAY STAND TO YOUR WALL (IF PURCHASED, CONTINUED)
WARNING: When securing to a wall with steel or wood studs, your mounting hardware must hit the stud through both top and bottom keyhole slot locations on at least one side of your display stand for proper support. ADVERTENCIA: Al asegurar a una pared con de acero o madera estructuras, su hardware de montaje debe fijarse al material a través de ambos lugares de ranura de ojo de cerradura superior e inferior en al menos un lado de su soporte de pantalla para un soporte suficiente. AVERTISSEMENT: Lors de la fixation à un mur avec des montants en acier ou en bois, votre matériel de montage doit toucher le montant à travers les emplacements des fentes en trou de serrure supérieur et inférieur sur au moins un côté de votre présentoir pour un support approprié.

5. The remaining sections of this topic show you how to attach the display stand to your specific wall type as follows:
· “Attaching the Display Stand to a Wall With Steel Studs or Cinderblocks” on page 14. · “Attaching the Display Stand to a Wall With Wood Studs” on page 15. · “Attaching the Display Stand to a Solid Concrete Wall” on page 15.
NOTE: If your installation requires additional measurements and details, refer to the technical specification (120-00027) at www.legrandav.com.

Attaching the Display Stand to a Wall With Steel Studs or Cinderblocks
NOTE: Adjust torque on power driver to the “drill” setting.
1. Use electric drill and ½” drill bit to drill holes in all the marked keyhole slot locations. You must hit wall studs (where applicable) in top and bottom keyhole slots on at least one side of the display stand for proper support.
NOTE: If securing to cinderblocks, avoid drilling into webs and sides as shown. (FIGURE D)

Web
Sides
FIGURE D

Plastic Cap

Metal Channel

2. Insert SNAPTOGGLE® anchor (B) into a hole by holding the metal channel flat alongside the plastic straps and sliding the channel through the hole as shown. (FIGURE E)

B

Plastic

Straps

3. Make the plastic strap handles even to force the metal channel perpendicular to the entire anchor. (FIGURE F)
FIGURE E 4. Secure the anchor by firmly sliding the plastic cap along the straps until the flange of the cap is flush with the wall.

5. Snap off plastic straps from the anchor by carefully bending them toward the wall. (FIGURE G)

6. Repeat steps 2 – 5 to insert SNAPTOGGLE anchors (B) into all of your keyhole slot location holes drilled during step 1.
NOTE: Adjust torque on power driver to lightest setting and only increase as necessary.

Making handles even forces metal channel perpendicular to entire anchor.
Handles
Slide plastic cap along straps.
Plastic Cap

7. Team lift the display stand and place it against your mounting wall aligning keyhole slots with the

FFIIGGUURREE FF

prepared holes and anchors.

Page 14

Metal Channel

ATTACHING THE DISPLAY STAND TO YOUR WALL (IF PURCHASED, CONTINUED)

Bend straps toward wall to remove from anchor.
FIGURE G

8. Place a level on the top center of your display stand and make any final adjustments to the leveling feet (by carefully team tilting the display stand) as necessary.
9. Use electric drill, 7/16″ socket, (4x) ¼”-20 x 2½” bolts (C) and (4x) ¼”-20 washers (D) through keyhole slots and into the anchors to secure the stand to your wall.

Attaching the Display Stand to a Wall With Wood Studs

NOTE: Adjust torque on power driver to the “drill” setting.

1. Use protective eyewear, electric drill, and 3/32″ drill bit to drill holes in all the marked keyhole slot locations. You must hit wall studs in top and bottom keyhole slots on at least one side of the display stand for proper support.

NOTE: Adjust torque on electric drill to lightest setting and only increase as necessary.

2. Team lift the display stand and place it against your mounting wall aligning keyhole slots with the prepared holes and anchors.

3. Place a level on the top center of your display stand and make any final adjustments to the leveling feet (by carefully team tilting the display stand) as necessary.

4. Use electric drill, 7/16″ socket, (6x) ¼ “x 2½” lag bolts (C, not provided), and (6x) ¼”-20 washers (D) through keyhole slots and into the drilled holes to secure the stand to your wall.

Attaching the Display Stand to a Solid Concrete Wall

NOTE: When securing your display stand (A) to a solid concrete wall, you must provide your own concrete anchors that support the weight ratings specified in “Weight Ratings” on page 9.
Secure your display stand (A) to a solid concrete wall by using a procedure similar to “Securing the Display Stand to a Wall With Steel Studs or Cinderblocks” on page 14.
REMOVING THE DOORS FROM YOUR DISPLAY STAND

1. Use side door keys (J) to unlock the outer doors from the lower bay. (FIGURE H)

NOTE: Door locks are located on side of display stand. Right door lock shown.

FIGURE H
2. Carefully push outer doors into the open position as shown. (FIGURE J)

FIGURE J

NOTE: Middle door cannot be removed until outer doors are removed or opened.
Page 15

REMOVING THE DOORS FROM YOUR DISPLAY STAND (CONTINUED) 3. Push the the sliding rail outward while pressing the release lever until it is exposed. (FIGURE K)

Release Lever

NOTE: Press the release lever

Locked in Open Position
Release Lever
NOTE: Push the rail outward

NOTE: Outer left door shown
open.

Unlocked from Open Position

FIGURE K

4. Pull and lift to remove the door completely from the sliding rail and set aside for re-installation. 5. Repeat steps 3 and 4 for the other outer door.

Magnet locations.
FIGURE L
NOTE: Bare frame of display stand shown for clarity.

NOTE: Secured with magnets, the middle door remains in place after removing the outer doors.
6. Pull the middle front door to remove it and set aside for re-installation. (FIGURE L)

Close up of latch with lock.

FREE STANDING DISPLAY STAND ONLY: A separate set of 3 door keys (H) provided for the rear doors.
7. Use a rear door key (H) to unlock each door (left, middle, and right).

8. Pull the latch until the door opens as shown. (FIGURE M)

NOTE: Door is in open position.

9. Lift up the door to remove it and set aside for re-installation. Repeat the previous two steps to remove the remaining doors.

FIGURE M

Page 16

REPOSITIONING THE 10″ LEVER LOCK PLATE
NOTE: · One 10″ Lever Lock plate (E) is pre-installed
inside of the display stand. For more information, contact support at av.support@legrand.com or (866) 977-3901. · This topic shows how to reposition your pre-installed 10″ Lever Lock (E), if needed.
1. Press the clip and lift the same side of the 10″ plate from the display stand column. (FIGURE P)
2. Reverse the steps (inserting the 10″ plate tabs on the on the side without the clip first) to re-install the 10″ plate to a new location inside the display stand, if desired.
NOTE: · There are 4x mounting positions available for the
three upper columns on the front and rear side of the display stand. (FIGURE N) · The bottom-middle bay has (3x) mounting positions available for one Lever Lock plate in three different locations (first, second, and third column).
3. Insert securing rivets (F) on the tab beneath the clip of the 10″ plate to lock it in place.

NOTE: Lever Lock plate can be repositioned in the top three storage columns and in the bottom-middle
column from the front or the back, as desired.

1

2

NOTE:

· There are

3

4x mounting positions

available on

each side.

4 · More than one

plate can be

installed.

Bottom-middle bay mounting
positions

FIGURE N

E Clip

F Side with

clip

FIGURE P

Side without clip

TIP: If necessary, you can remove the securing rivet by pushing its tip end out of the hole with a small screwdriver, and then pulling by hand at the rivet’s head.

Page 17

USING TOP SMALL DEVICE STORAGE AND BOTTOM RACKMOUNT BAYS

1. After installing your equipment, run cabling using openings between the top small device storage columns and the bottom rackmount bays, if needed.

FLOOR-TO-WALL DISPLAY STANDS ONLY: Load components into the top small device storage columns and bottom bays at this point in the overall installation and configuration process because access to these areas is more difficult after re-installing the front panel and mounting your display.
NOTE: · Bottom-outside bays on all display stand models
includes 2RU rackrail pairs for device storage that may be re-positioned in 7 vertical 1.5″ (38mm) increments. · Adjust torque on electric drill to lightest setting and only increase as necessary.

Top Small Device Storage Columns
(Shaded for Clarity)
FIGURE R Bottom Bays
(Shaded for Clarity)

2. Use electric drill and a 5/16″ socket to remove the 10-32 nuts, reposition the rackrail brackets to the same height, and re-install the nuts as necessary. (FIGURE R)

NOTE: Bare frame of display stand shown for clarity.

3. Attach devices to the rackrail using a #2 Phillips screwdriver and rack screws (not provided).

NOTE: If you are installing equipment to higher rackrail positions in the outer bottom bays, use a short, stubby #2 Phillips screwdriver or a mini ratchet wrench with a #2 Phillips bit to tighten rack screws (not provided). (FIGURE S)

NOTE: Rackrail brackets in outer bottom bays shown in black for clarity.

10-32 Nut on Rackrail Bracket
OR
FIGURE S

Page 18

DETERMINING THE DEFAULT HEIGHT FROM THE FLOOR TO THE BOTTOM OF YOUR DISPLAY
Use the following steps to determine the height from the floor to the bottom edge of your display when mounted on your display stand.

1. Locate the diamond-shaped holes punched into each column of the top small device storage area of your display stand as shown. (FIGURE T)

Diamond-shaped hole punched into each column of the top small device storage area.

NOTE: The diamond holes are located 52″ (1.32 m) from the floor.

FIGURE T

2. Confirm the location of the VESA pattern on the back of your display (display not provided).

Center of VESA pattern
Ucmeanttcehreosf
display.

CENTERED VESA PATTERN: VESA patterns are often centered on the back of displays. (FIGURE U)
FIGURE U

OFFSET VESA PATTERN: Sometimes, VESA patterns are offset below the center of displays. If the VESA pattern on the back of your display is offset, measure the difference between the center of the pattern and the center of your display. (FIGURE V)

Center of VESA pattern offset from
center of display.

Measure this
amount.
FIGURE V

3. Use the data from the previous steps to subtract ½ the height of your display (if VESA is centered) or ½ the height of your display and the offset (if applicable) from the 52″ (1.32 m) height level. The result is the height from the floor to bottom edge of your display.

Formula if VESA pattern centered on back of display:
52″ (1.32 m) — ½ Height of Your Display = ?

52″ (1.32 m) — ½ Height of Your Display — VESA Offset Amount = ?

PPaaggee 1199

CUSTOMIZING THE HEIGHT FROM THE FLOOR TO THE BOTTOM OF YOUR DISPLAY
Use the following step to customize the height from the floor to the bottom edge of your display using the default height calculated in the previous topic.

· Use the default height calculated to determine how much higher or lower you would like the bottom edge of your display in 2″ (50.8 mm) increments.
NOTE: Hole sets for customizing the height of your display are shown. (FIGURE W)

NOTE: Hole sets shown are spaced
in 2″ (50.8 mm) increments.

FIGURE W

ATTACHING HORIZONTAL BRACKETS, EXTRUSION, AND MAKING ADJUSTMENTS

Based on the desired bottom edge of your display, plan to install all of your horizontal extrusion brackets (AA) to higher or lower hole sets from where the diamond holes on the brackets and the display stand align.

NOTE: The hole sets shown for the brackets are spaced vertically in 2″ (50.8 mm) increments. (FIGURE X)

TIP: Refer to dimension specifications provided with your display.

1. Attach all horizontal extrusion brackets (AA) at the same level higher or lower than diamond holes by 2″ (50.8 mm) increments on the display stand.

Diamond holes on horizontal extrusion brackets match the ones on the display stand for the 52″ (1.32 m) height to center
of display.
FIGURE X

NOTE: Back view of upper frame shown.

2. By hand, put (2x) 5/16-18 x 1″ machine screws (AB) through keyhole

slots where the horizontal extrusion bracket (AA) and the desired

hole set on display stand (determined from the previous topic) align,

and thread (2x) 5/16″-18 hex nuts (AC) onto the screws as shown. Do

AC

not tighten. (FIGURE Y)

3. Repeat the process to attach the remaining brackets, all at the same hole set height, onto your display stand.

FIGURE Y

Page 20

ATTACHING HORIZONTAL BRACKETS, EXTRUSION, AND MAKING ADJUSTMENTS (CONT.)

4. Slide horizontal extrusion (P) into interlock tabs

found on horizontal extrusion brackets (AA,

positioned loosely), as shown. (FIGURE Z)

P

NOTE: For dual and Jupiter 105″ display installations, make sure to attach both extrusions at this point.

Interlock Tabs
AA

FIGURE Z FOR SINGLE DISPLAY INSTALLATIONS (EXCEPT JUPITER 105″): Proceed to the final step.
FOR DUAL DISPLAY AND SINGLE JUPITER 105″ DISPLAY INSTALLATIONS:
5. Refer to corresponding “Chief Fusion Modular Mounting Rails, Connectors and End Cap Kits” installation instructions for the Connecting Bracket kit (FMSHC1) at www.legrandav.com. The connecting bracket kit installation instruction provides details for the coupling of (2x) horizontal extrusions (P).

NOTE: For floor to wall models, reach behind the horizontal extrusion (P) to tighten the connecting bracket.

TIP: Use a short, stubby #2 Phillips screwdriver or a mini ratchet wrench with a #2 Phillips bit, if necessary.

6. While referencing the Chief Fusion Modular Mounting Rails, Connectors and End Cap Kits installation instruction, use hex key and 10-24 x 1-½” flat head cap screw to secure the connect bracket to front of mounting rail. (FIGURE AA)

7. Use 3/16″ hex key, 5/16 x ” button head cap screw, 5/16″ split washer, and friction washers to fasten connector plate. (FIGURE AB)
8. Use ” hex key and 10-24 x 1-½” flat head cap screw to secure the connect bracket to front of second section of mounting rail.
9. Repeat Step 7 to fasten connector plate and completely secure it to the connect plate.

NOTE: Back of extrusion shown.

FIGURE AA
NOTE: Front of extrusion shown.
FIGURE AB

10. Use socket wrench and ½” socket to tighten machine screws and nuts (previously tightened by hand) to the horizontal extrusion brackets (AA).

Page 21

ATTACHING SHROUD BRACKETS AND MAKING ADJUSTMENTS
Based on the desired height of your horizontal extrusion and the number of your displays, plan to prep and install the shrouds at the same level.
NOTE: Attach shroud interface bracket (M) and rear shroud bracket (N) to have a fully prepped shroud before mounting it on the display stand.

Use hole set highlighted if Y
VESA pattern is centered.

1. Attach shroud interface bracket (M) to front of shroud before securing the hardware.

Use hole below center for 105″ Jupiter displays only.
FIGURE AC

CENTERED VESA PATTERN: Use the marked hole set shown. (FIGURE AC)
OFFSET VESA PATTERN: · Take the offset amount from page 19 and use the holes for that
distance below the marked hole set shown. · For Jupiter 105″ displays only, use hole below centered holeset.

2. By hand, screw (2x) ¼”-20 flange nuts (Y) onto (2x) studs located on the front of shroud, to secure the shroud interface bracket (M) to the shroud (L).

FOR JUPITER DISPLAYS: Hole pattern on shroud may vary.

NOTE: Back of shroud shown.

NOTE: Adjust shrouds based on your display(s) overall length.

N
FIGURE AD

At this location the shrouds are fully extended.

3. Attach side containing (3x) rear shroud bracket (N) studs to the (3x) corresponding keyholes located on back of shroud (L). (FIGURE AD)

FIGURE AE

TIP: For large display sizes use innermost hole set and for smaller display sizes use outermost hole set, as shown. (FIGURE AE)
4. By hand, tighten (3x) ¼”-20 flange nuts (Y) onto studs located on the front of shroud.

5. Repeat the previous steps to assemble brackets on the second shroud before mounting them on the display stand.
NOTE: · Procedure is similar for dual display installations. · Ensure both shrouds are fully prepped before attaching them to the display stand.

WARNING: This procedure requires at least one additional person. ADVERTENCIA: Este procedimiento requiere al menos una persona adicional. AVERTISSEMENT: Cette procédure nécessite au moins une personne supplémentaire.

Page 22

ATTACHING SHROUD BRACKETS AND MAKING ADJUSTMENTS (CONTINUED)
NOTE: Attach shroud (L) to the display stand at the same level of your desired height, which was established in previous topics.

Interlock Tab

6. Carefully team lift shroud and slide interlock tabs located on shroud interface bracket (M) into the (2x) channels found on the back end of the horizontal extrusion (P). (FIGURE AF)

NOTE: Back view of

N

upper frame shown.

Interlock Tab
Slide shroud interface bracket into extrusion.
FIGURE AF

Tighten nuts from inside of the frame.

L
FIGURE AG

NOTE: As one person slides the interlock tabs into the horizontal extrusion, have another person align rear shroud bracket studs with obround holes (shaded for clarity) on the side of frame. (FIGURE AG)
7. By hand, tighten (2x) ¼”-20 flange nuts (Y) onto (2x) rear shroud bracket studs from the inside of the frame.

8. At this point, make any desired adjustments to the shroud height or width based on your display dimensions. (FIGURE AH)

NOTE: · Adjust torque on electric drill to lightest setting and
only increase as necessary. · Return to steps 2 and 5 to secure hardware
previously tightened by hand.

Desired Width

Desired Height

9. Use an electric drill and 7/16″ socket to tighten ¼”-20 flange nuts (Y) to secure the shroud interface bracket (M) to shroud (L). Do not overtighten.

FIGURE AH

10. Use an electric drill and a 7/16″ socket to tighten ¼”-20 flange nuts (Y) to secure the rear shroud bracket (N) to the display stand (A). Do not overtighten.

Adjust bolt to create an angle of lean for
your display.

NOTE: The shroud interface bracket (M) is designed to create a small angle of lean for your display.
11. Use a 3/16″ hex key to adjust the angle of lean, if necessary. (FIGURE AJ)

FIGURE AJ

Page 23

ATTACHING SHROUD BRACKETS AND MAKING ADJUSTMENTS (CONTINUED)

NOTE: Once shrouds are fixed to your display stand, proceed to attaching front and bridge panels.

12. Attach front panels, previously removed in “Removing the Panels from Your Display Stand” on

page 12, behind shroud.

Screw Locations Circled

13. Attach bridge panels (R) behind shroud (L).

Bridge Panels

NOTE: Position bridge panels to cover any gaps

that may be visible. (FIGURE AK)

Front Panels

14. Use a #2 Phillips screwdriver and (8x) 12 x ”

sheet metal screws (S) to secure bridge and shroud

panels. Do not overtighten.

ATTACHING END CAPS TO HORIZONTAL EXTRUSION

FIGURE AK

FIGURE AL

NOTE: Verify the torque on your electric drill is on the lightest setting and only increase as necessary.
· Use electric drill, #2 Phillips bit, extrusion end caps (T) and (4x) ¼”-20 x ½” end cap screws (U) to attach an end cap on each end of the horizontal extrusion (P). (FIGURE AL)

SELECTING THE CORRECT INTERFACE BRACKET HARDWARE FOR YOUR DISPLAY

NOTE: The interface hardware kit provided includes different pan head screws (IP-A) to accommodate

the threaded inserts on the back of most displays. This topic helps you select the correct size pan head

screw length for your display.

1. Use a toothpick or small straw as a thread depth indicator and insert it into a threaded insert on the back of your display.

Thread Depth
Indicator
(Toothpick or Straw)

2. With the toothpick or straw fully inserted, use a pencil to mark it at ” above the surface as shown. (FIGURE AM)

Mark ” Above Depth

IP-A

Depth Plus ” Allowance
Mark

Thread Depth Indicator
(Toothpick or Straw)
FIGURE AN

FIGURE AM
3. Select a pan head screw (IP-A) size that is shorter in length than the ” mark you made on your thread depth indicator. (FIGURE AN)
CAUTION: Only use screws shorter than the ” mark or damage to the display may occur. PRECAUCIÓN: Solo puede haber tornillos más cortos que la marca ” o puede haber daños en la pantalla. ATTENTION: N’utilisez que des vis plus courtes que la marque ” ou vous risquez d’endommager l’écran.
Page 24

ATTACHING INTERFACE BRACKETS TO THE BACK OF YOUR DISPLAY

NOTE: Install any additional accessories you may have purchased (camera mounts, sound bars and other audio products available from Legrand or other providers) before mounting your display.
Before proceeding, refer to the instructions provided with your accessory for the proper installation order.
1. Carefully place your display facedown onto an appropriate work surface.
NOTE: Center the display interface brackets (Z) on your display so they do not extend past the top or bottom.
2. Determine the correct size pan head screws for attaching the interface brackets to your display. For more information, see the previous topic.
3. Determine if spacers (IP-B) are required when attaching the interface brackets to the back of your display.
NOTE: Adjust torque on electric drill to lightest setting and only increase as necessary.
4. Use electric drill, #2 Phillips bit, (4x) spacers (IP-B, if required), (4x) washers (IP-C), and (4x) correct length pan head screws to attach the interface brackets to the back of your display as shown. (FIGURE AP)
NOTE: · Spacers may be needed between the interface bracket and display for clearance and added depth. · The hardware used must be assembled in the arranged order shown in this topic. · A minimum of (2x) pan head screws, washers, and spacers (if spacers required) must be used
on each interface bracket.

Mounting Screws

NOTE: Install any additional

Z

IP-A

accessories you may have

purchased before mounting

IP-C

your display.

IP-B
FIGURE AP

FOR DUAL DISPLAY INSTALLATIONS: Repeat the previous steps to attach the display interface brackets (Z) to the back of your second display.

Page 25

ATTACHING INTERFACE BRACKETS TO THE BACK OF YOUR DISPLAY (CONTINUED)

FOR SINGLE JUPITER 105″ DISPLAY INSTALLATIONS: Assemble interface and adapter brackets prior to attaching it to your display.

NOTE: Use upper-most circular hole on interface
bracket.

NOTE: Adjust torque on electric drill to lightest setting and only

Stud

increase as necessary.

5. Use socket wrench, (4x) and (4x) 5/16″-18 hex nuts (V) to attach the adapter bracket (W) to the interface bracket (Z) as shown. (FIGURE AR)
IP-A

Adapter Bracket

Interface Bracket

IP-C

IP-B

FIGURE AR

6. Use electric drill, #2 Phillips bit, (4x) spacers (IP-B), (4x) washers (IP-C), and (4x) pan head screws (IP-A) to attach the assembled bracket to the back of your display as shown. (FIGURE AS)

FIGURE AS LEVELING YOUR DISPLAY STAND (FREE-STANDING MODELS ONLY)

NOTE: · Leveling mounts are provided in case the level of your
display stand requires adjusting. (FIGURE AT) · The following topic provides information on how to
re-adjust the leveling mounts for your model.

Leveling Mounts FIGURE AT

G FIGURE AU

1. Use a socket wrench and 5/16″ socket to re-adjust the level of your display stand.
NOTE: Reach the leveling mount from the top surface of base.

2. Use (6x) ” dome plugs (G) to cover holes exposing the leveling mounts as shown. (FIGURE AU)

Page 26

HANGING YOUR DISPLAY
WARNING: This procedure requires at least one additional person. ADVERTENCIA: Este procedimiento requiere al menos una persona adicional. AVERTISSEMENT: Cette procédure nécessite au moins une personne supplémentaire.
1. With at least one other person, carefully lift your display slightly above your horizontal extrusion (P). (FIGURE AV)

2. Slowly lower the display while ensuring top interface bracket hooks fully engage onto the top of the horizontal extrusion (P).
Z
WARNING: Do not release your display until certain the top hook of each interface bracket is securely seated on the upper edge of your horizontal extrusion. ADVERTENCIA: No suelte la pantalla hasta que el gancho superior de cada soporte de interfaz esté firmemente sentado en el borde superior de la extrusión horizontal. AVERTISSEMENT: Non rilasciare il display fino a quando il gancio superiore di ogni staffa di interfaccia non è fissato saldamente sul bordo superiore dell’estrusione orizzontale

Top Hooks on Interface Brackets

Horizontal Extrusion

Interface Bracket Release Cords

FIGURE AV

3. Carefully bring the lower side of the display forward until the lower jaws of the interface brackets securely latch onto the bottom edge of the horizontal extrusion.
NOTE: Remove your display by pulling both release cord rings down while pulling bottom of the display away and then team lift it off the horizontal extrusion.
TIP: Store release cords behind your display by attaching the magnetic rings to the metal interface brackets.
RE-ATTACHING THE PANELS TO YOUR DISPLAY STAND
NOTE: · Any indentations made to the acoustic felt (PET) material of the front or side panel may be
removed by applying steam. · Remove dust and debris from panels with a clean, soft, lint-free cloth or vacuum. · Bleach and cleaning agents are not recommended, as they may discolor the material. · Carefully re-install both front and side panels by reversing the steps in “Removing the Panels from
Your Display Stand” on page 12.
FOR FREE-STANDING MODELS: Re-install back panels by reversing the steps in “Removing the Panels from Your Display Stand” on page 12.
Page 27

RE-ATTACHING THE DOORS TO YOUR DISPLAY STAND 1. Align outer and inner sliding rails before pushing doors
inward. (FIGURE AW)
NOTE: If sliding rails are misaligned, the door may fall off or not close properly.
2. Push doors inward.
NOTE: The door is secured when the release lever, inner and outer sliding rails are locked, as shown. (FIGURE AX)

Outer Sliding Rail

Inner Sliding Rail

Outer Sliding Rail

Release Inner Sliding

Lever

Rail

FIGURE AW

FIGURE AX WARRANTY For warranty information, refer to www.legrandav.com/policies/warranty_information.

Contacting Corporate Headquarters P: (866) 977-3901 | F: (877) 894-6918 | www.legrandav.com | av.support@legrand.com

Contacting Middle Atlantic Canada P: (888) 766-9770 | F: (888) 599-5009 | ca.middleatlantic.com | av.canada.customerservice@legrand.com

Contacting Middle Atlantic Europe, Middle East, and Africa (EMEA) Technical Support P: +31 495-726-003 | av.emea.middleatlantic.support@legrand.com

United States (US)
Legrand | AV Headquarters 6436 City West Parkway
Eden Prairie, MN, 55344, USA

European Union (EU)
Legrand AV Netherlands B.V. Franklinstraat 14 6003
DK, Weert, Netherlands

United Kingdom (UK)
Starline Holding Technology Ltd.
(Authorized Representative)
Unit C, Island Rd. Reading RG2, 0RP- UK

At Legrand AV Inc. we are always listening. Your comments are welcome. Legrand AV is an ISO 9001 and ISO 14001 Registered Company.

Page 28

Documents / Resources

MIDDLE ATLANTIC FM-DS-6675FW-LD8W Display Stand for Single and Dual Displays [pdf] User Manual
FM-DS-6675FW-LD8W Display Stand for Single and Dual Displays, FM-DS-6675FW-LD8W, Display Stand for Single and Dual Displays, Stand for Single and Dual Displays, Single and Dual Displays, Dual Displays

References

Leave a comment

Your email address will not be published. Required fields are marked *