ZAHEES ZM2033 Electronic Bidet Toilet 

ZAHEES ZM2033 Electronic Bidet Toilet

PARTS IDENTIFICATION

Left side 

Parts Identification

Right side 

Parts Identification

Installation of ceramic toilet

Water supply angle valve installation

  • Draw drain outlet centerline on the floor, install angle valve at proper position on wall according to dimension of toilet. 10″ off center is preferred.
    Installation of ceramic toilet

Cardboard installation

  • Align cardboard with the centerline of drain outlet.
  • Outline with pencil or tape according to cardboard.
  • Please mark the position of flange bolts.
    Installation of ceramic toilet

Mounting bracket installation

  • Assemble the mounting L-Bracket with bolts and then install them to the pre-install flange plate on the ground and tighten with nuts.
    Installation of ceramic toilet

Ceramic toilet installation

  • Install wax ring onto drain outlet of toilet.
  • Carefully lower toilet into place directly according to the outline position.
    Installation of ceramic toilet

Attention:
This toilet is team-lift recommend, also seat should be in open position to aid in installation.

Installation of ceramic toilet

  • Install Screw through Plastic Insert and into the opening on the side of the toilet. Tighten Screw into L-Bracket being careful not to over tighten.

Silicone caulking application

  • Apply Silicone caulking to the edge of toilet base, wipe away any excess.
    Installation of ceramic toilet

Note:
Please clean the drain outlet; Please make sure ceramic toilet outlet sits perfectly on drain outlet.

Installation of hose 

  • Connect water inlet and angle valve with new hose.
    Installation of ceramic toilet

Before Installation

  1. Turn on the angle valve
    Check thread connection, make sure no leakage is found.
    Before Installation
  2. Power Connection
    • Insert power line leakage protection plug into the power socket, press the reset switch, plug indicator lights on indicating that the power is on.
    Before Installation
    Tips:
    Press electric leakage test button prior to usage, the reset switch pops up indicating that the leakage protection function is normal.
    Press the TEST button (then RESET button) every month to assure proper operation.
    *Suitable for the product with leakage protection plug.
    *Please refer to the actual product.
  3. Self-inspection 
    1. The main unit buzzer rings first “click”, power indicator (POWER) and Energy-conservation indicator (ENERGY SAVER) flash. Power indicator lights on and Energy-conservation indicator
    2. gets off to start self-inspection.
    The main unit buzzer rings second “click” to indicate finish of self-inspection, power indictator lights on, and Energy-conservation indicator keeps off.
    3. Start function mode for normal usage.

Daily maintenance

Main unit care and maintenace

  1. Shut off power supply at maintenance.
  2. Turn the seat upward open, press down the button located on the right side of main unit and pull out the seat. Wipe the stain with a soft damp cloth.
    Daily maintenance
  3. Safety self- inspection
    After cleaning, re-connect the toilet with the power supply

Spray nozzle maintenance and care

  1. Nozzle self-cleaning
    The nozzle will be cleaning automatically before washing and after washing
  2. Nozzle manual-cleaning
    Open the lip and seat , then rotate the knob in the clockwise direction .
    The nozzle will extend forward.
    Daily maintenance
  3. Use soft cloth or soft brush to clean
    Do not pull or push the wand, to avoid damage.
    Daily maintenance
  4. top cleaning
    Press the knob then the nozzle will go back .

Emergency Troubleshooting

Electricity and water supply cut-off 

  1. Power failure
    •Press the reset switch
    Emergency Troubleshooting
  2. Water failure
    •Put around 8L water into a barrel and flush the bowl of ceramic.
    Note: Avoid water spilling from bowl.
    Emergency Troubleshooting

Failure of remote control 

  1. Operate the knob on bidet seat to perform.
    Emergency Troubleshooting
  2. Battery replacement
    Remove the cover of the remote control
    Emergency Troubleshooting
    Put into two pieces of AAA battery , then reinstall the cover
    Emergency Troubleshooting
  3. Battery of toilet replacement or installing
    • Put up the electronic bidet from hind side
    Emergency Troubleshooting
    • Recover the cover of b attery
    Emergency Troubleshooting
    • Put into one piece of 6LR61 battery Recover the cover
    Emergency Troubleshooting

The illustration of main unit keys

The illustration of main unit keys

Rear wash Rear wash Be seated then rotate the knob in the clockwise direction

Front wash Front wash Be seated then rotate the knob in the anticlockwise direction

Stop / Power Stop / Power Press it to stop washing or drying. Not be seated keeping presing the knob ,it will be power off. Keeping pressing again ,it will be power on again .

Foot controller

The illustration of main unit keys

ZM2033
When the foot is close to it , flushing will be worked

ZM2035
When the foot is close to it , the lip will be opened .
When close to it again , the seat will be opened.
When close to it third time , the lip and seat will be closed and flushed

Logo

Documents / Resources

ZAHEES ZM2033 Electronic Bidet Toilet [pdf] Instructions
ZM2033, ZM2033 Electronic Bidet Toilet, Electronic Bidet Toilet, Bidet Toilet, Toilet

References

Leave a comment

Your email address will not be published. Required fields are marked *