DSI Cera-Fix Porcelain Ceramic Repair System

DSI-Cera-Fix-Porcelain-Ceramic-Repair-System-product-image

Product Information

Specifications:

  • Product Name: DSI Cera-Fix Porcelain Ceramic Repair System
  • Manufacturer: DSI Israel
  • Contents: Porcelain Etching bottle, 5ml Primer Adhesive bottle, 5ml Protective Dam Gel prefilled syringe, 5ml Opaque Masking syringe, 3ml Applicator needles, 10pcs Mixing Accessories

Features:

  • Cera-Fix Porcelain Etching: Contains 9% hydrofluoric acid for etching fractured dental porcelain
  • Cera-Fix Protective Dam Gel: Buffered acid barrier to protect tissues and restorations
  • Cera-Fix Primer Adhesive: Universal light-cured bonding for direct and indirect bonding procedures
  • Cera-Fix Opaque Masking: Light-cured composite pigment for masking metal surfaces and dentine color imitations

Product Usage Instructions

Direct Pulp Capping:

  1. Isolate the field of operation.
  2. Clean the surface with abrasive paste and remove glaze surface.
  3. Apply Protective Dam Gel to protect surrounding areas.
  4. Apply Porcelain Etching on the chipped surface and leave for 180 sec.
  5. Blend Protective Dam Gel with the acid, suction, rinse & dry.
  6. Apply silane Primer Adhesive using a micro-brush applicator.
  7. Allow Primer Adhesive to evaporate for 20 sec and air dry if needed.
  8. Light cure for 20 sec.
  9. Complete restoration using composites and chosen techniques.

Important Note:
To avoid inhalation of irritating Porcelain Etching vapors, hold the vacuum in close proximity to the area being prepped.

FAQ

  • Q: What are the contents of the Cera-Fix Porcelain Repair Kit?
    A: The kit includes a Porcelain Etching bottle, 5ml Primer Adhesive bottle, 5ml Protective Dam Gel prefilled syringe, 5ml Opaque Masking syringe, 3ml Applicator needles, and 10pcs Mixing Accessories.
  • Q: How should I protect soft tissues during the bonding process?
    A: Apply the Protective Dam Gel as a buffered acid barrier to protect soft tissues and adjacent restorations during the procedure.

www.dsisrael.com

Porcelain Ceramic Repair System
DSI Cera-Fix

INSTRUCTIONS FOR USE

PURPOSE

Cera-Fix Etching set is used for preparing porcelain veneers, inlays and fractured porcelain teeth for bonding. Cera-Fix Porcelain repair kit contains all the products needed for composite-to-porcelain, porcelain-to-metal, and porcelain-to-porcelain repairs.

INDICATIONS

  • Conditioning of the ceramic veneers and glass-fiber posts.
  • Surface preparation for optimal bonding of the porcelain veneers.
  • Aesthetic repair of fractured porcelain crowns.
  • Surface preparation of porcelain crowns and inlays prior cementation.

FEATURES

  • Cera-Fix Porcelain Etching: Based on 9% hydrofluoric acid. Specifically designed to etch fractured dental porcelain, such as veneers, crowns, inlays. Can also be used in orthodontics for etching porcelain crowns before bonding.
  • Cera-Fix Protective Dam Gel: A buffered, gelled acid barrier/neutralizer protects soft tissues and adjacent restorations by neutralizing acid etchants upon contact. The bright orange color provides high contrast against tissues and acid etchants.
  • Cera-Fix Primer Adhesive: Universal light-cured bonding with an ethanol solvent carrier. Ideal for direct and indirect bonding procedures and repairs of composite, metal, zirconia and porcelain restorations.
  • Cera-Fix Opaque Masking: Light-cured, methacrylate-based, composite pigment, with an average particle size of 0.7μm and a low film thickness. It is strong and wear resistant and is effective at masking metal surfaces and natural dentine color imitations.

INSTRUCTIONS FOR USE

Direct Pulp Capping:

  1. Isolate the field of operation.
  2. Clean the surface to be etched with abrasive paste (DSI Diamond Paste Coarse) and removed the glaze surface by fine diamond bur or 50mkm aluminum oxide sandblasting. Rinse and air-dry.
  3. Apply a thin layer of the Protective Dam Gel on the mucosa and the restoration surrounding area to protect from the acid implant.
  4. Apply Porcelain Etching on the chipped surface. Leave undisturbed for 180 sec.
  5. Blend the Protective Dam Gel with the acid, suction, rinse & dry.
  6. Etched porcelain should have a frosted white appearance. Repeat if the surface does not appear frosted.
  7. Using the micro-brush applicator, apply the silane Primer Adhesive and allow it to evaporate for 20 sec. Air dry if needed.
  8. Preparation should receive a shiny appearance. Light cure for 20 sec.
  9. For surfaces with exposed metal, apply a thin coat of Opaque Masking. Light cure for 40 sec. More than one layer might be needed for a full metal concealing – repeat if necessary.
  10. Complete the restoration using composites and techniques of your choice.

Important: to avoid inhalation of irritating Porcelain Etching vapors, hold the vacuum in close proximity to the area being prepped.

STORAGE

  • Store in a dry and dark place in tightly closed containers at temperature (+5°C…+25°C).
  • Resins should be refrigerated for long-term storage to maintain shelf life.
  • Replace the cap immediately after use. Avoid contact with moisture!
  • After opening, keep only in original container.
  • Do not use after the expiry date mentioned on the outer package.

PACKAGING

Cera-Fix Porcelain Repair Kit contents:

  • Porcelain Etching bottle, 5ml
  • Primer Adhesive bottle, 5ml
  • Protective Dam Gel prefilled syringe, 5ml
  • Opaque Masking syringe, 3ml
  • Applicator needles, 10pcs
  • Mixing Accessories
  • Ref: CFX-KIT

Cera-Fix Etching Mini Kit contents:
Porcelain Etching Gel prefilled syringe, 5ml
Protective Dam Gel prefilled syringe, 5ml
Ref: CFX-MINI

SYMBOLS

  • Consult instructions for use
  • Caution, consult accompanying documents
  • Temperature limit
  • Keep away from sunlight
  • Keep dryDSI-Cera-Fix-Porcelain-Ceramic-Repair-System-01
  • Manufacturer
  • Catalogue number
  • Batch code
  • Use by
  • Date of ManufactureDSI-Cera-Fix-Porcelain-Ceramic-Repair-System-02

Failure to comply with the conditions of storage leads to a change of the working characteristics of the material and decrease the shelf life of the material.
The manufacturer is not responsible for any loss of quality caused by the failure to comply with terms of transportation, storage and use established by the manufacturer for this product. Responsibility for the use of the material for purposes other than those specified by the manufacturer falls on the user.

Documents / Resources

DSI Cera-Fix Porcelain Ceramic Repair System [pdf] Instructions
Cera-Fix Porcelain Ceramic Repair System, Cera-Fix, Porcelain Ceramic Repair System, Ceramic Repair System, Repair System, System