MOXA IKS-6700A/ IKS-6728A-8PoE Series Industrial Rackmount Switch

MOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-PRODUCT

Product Information

The IKS-6700A/IKS-6728A-8PoE Series is a rackmount switch manufactured by Moxa Inc. It is designed for industrial use and offers Fast Ethernet connectivity. The switch comes with various features, including grounding capabilities, power input options, relay contact for event detection, USB ports for console access and configuration, and a reset button for loading factory default settings.

Package Checklist

The package includes the IKS-6700A/IKS-6728A-8PoE Series rackmount switch along with the necessary accessories.

Panel Layouts

The switch has power inputs, AC power inlets, DC power terminal blocks, a relay contact terminal block, USB ports, and a reset button.

Grounding the Moxa Industrial Rackmount Switch

To limit the effects of noise due to electromagnetic interference (EMI), it is recommended to ground the switch. Connect the ground screw to the grounding surface before connecting any devices. It is advised to use shielded cables for better electromagnetic compatibility.

Connecting the Power Inputs

Ensure that the power is switched off or the area is non-hazardous before disconnecting modules or wires. The switch should only be connected to the specified supply voltage mentioned on the type plate. It is designed to operate with a Safety Extra-Low Voltage (SELV) or an isolated power supply in compliance with IEC 60950-1/EN 60950-1 or UL 508.

AC Power Inlets

PWR1 (power supply 1) and PWR2 (power supply 2) connections are located on the rear panel. Use a standard power cord with an IEC C13 connector compatible with the AC power inlet.

DC Power Terminal Blocks

EPS1 (external power supply 1) / PWR1 (power supply 1) and EPS2 (external power supply 2) / PWR2 (power supply 2) connections are located on the rear panel. Follow the steps below for wiring:

  1. Insert the negative/positive DC wires into the V-/V+ terminals, respectively.
  2. Tighten the wire-clamp screws using a screwdriver to prevent the wires from pulling loose.

Wiring the Relay Contact

Each switch has one relay output. The relay contact of the 2-pin terminal block connector is used to detect user-configured events. The fault circuit remains closed when no user-configured event occurs. Ensure proper wiring according to the instructions provided.

USB Connection

The switch has two USB ports on the front panel:

  • Type B USB-serial console port
  • Type A USB host port

To connect the USB-serial console port to your PC’s COM port, use a USB cable (type A male to type B male) and install the USB driver from the software CD on your PC. You can then use a console terminal program, such as Moxa’s PComm Terminal Emulator, to accessthe console configuration utility of the switch.
To connect to the USB host port for various purposes, including backup and restore configuration files, auto-loading configuration files, firmware upgrades, and system log file backups, use Moxa’s USB Automatic Backup Configurator ABC-02-USB.

The Reset Button

Press and hold the Reset button for five continuous seconds to load the factory default settings. Use a pointed object, like a straightened paper clip or toothpick, to depress the Reset button.
The STATE LED will start blinking about once per second. Continue pressing until the STATE LED blinks more rapidly, indicating that the button has been depressed for five seconds. Release the Reset button to load the factory default settings.

Technical Support Contact Information www.moxa.com/support

Package Checklist

The Moxa IKS-6700A/IKS-6728A-8PoE industrial rackmount switch is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.

  • IKS-6700A/IKS-6728A-8PoE switch
  • USB cable (Type A male to Type B male)
  • 4 protective caps for unused ports
  • Power cord
  • 2 rackmount ears
  • Quick installation guide (printed)
  • Warranty card

Panel LayoutsMOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (1)

  1. System status LEDs
  2. Model name
  3. Reset button
  4. Terminal block for relay output
  5. USB serial console port
  6. USB storage port (ABC-02-USB-T)
  7. 10/100/1000BaseT(X) or 100/1000Base SFP combo ports
  8. 100/1000Base SFP port status LEDs
  9. PoE+ status LEDs (IKS-6728A-8PoE series only)
  10. 10/100BaseT(X) port status LEDs
  11. Fast Ethernet or PoE+ interface ports
  12. Fast Ethernet or PoE+ interface modules
  13. Terminal blocks for DC power inputs
  14. Grounding screw
  15. Power sockets for AC power inputs or terminal blocks for DC power inputs

DimensionsMOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (2) MOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (3)

Unit = mm (inch)

Fast Ethernet Interface Modules (IM-6700A Series)MOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (4)

Grounding the Moxa Industrial Rackmount Switch

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
NOTE Using a shielded cable achieves better electromagnetic compatibility.

Connecting the Power Inputs

The IKS-6728A-8PoE switches support 4 types of power supply.

  • IKS-6728A-8PoE-4GTXSFP-HV-HV-T: Two isolated 110/220 VAC (85 to 264 VAC) power supplies for switch and two isolated 48 VDC power inputs for PoE+ ports
  • IKS-6728A-8PoE-4GTXSFP-HV-T: One isolated 110/220 VAC (85 to 264 VAC) power supply for the switch and one isolated 48 VDC power input for the PoE+ ports
  • IKS-6728A-8PoE-4GTXSFP-48-48-T: Two isolated 48 VDC power supplies for switch and PoE+ ports
  • IKS-6728A-8PoE-4GTXSFP-48-T: One isolated 48 VDC power supply for switch and PoE+ ports

For the HV models, the 110/220 VAC power supplies provide power for switch operation. Separate 48 VDC power supplies are required to provide power to all PoE+ ports (50 to 57 VDC is recommended for IEEE 802.3at devices).
For the 48 VDC models, the 48 VDC power supplies provide power for switch operation and to all PoE+ ports (50 to 57 VDC is recommended for IEEE 802.3at devices).

The IKS-6700A switches support 3 types of power supply:

  • IKS-6726A/6728A HV series: Two isolated 110/220VAC (85 to 264 VAC) power supplies for switch
  • IKS-6726A/6728A 24/48VDC series: Two isolated 24 or 48VDC power supplies for switch

Wiring Requirements

WARNING
Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The device may only be connected to the supply voltage shown on the type plate. The device is designed for operation with a Safety Extra-Low Voltage (SELV) or an isolated power supply, which means that they may only be connected to the supply voltage connections and to the signal contact with a SELV or an isolated power supply in compliance with IEC 60950-1/EN 60950-1 or UL 508.

AC Power Inlets
The connection for PWR1 (power supply 1) and PWR2 (power supply 2) are located on the rear panel (shown below). Be sure to use a standard power cord with an IEC C13 connector, which is compatible with the AC power inlet.

DC Power Terminal Blocks
The connection for EPS1 (external power supply 1) / PWR1 (power supply 1) and EPS2 (external power supply 2) / PWR2 (power supply 2) are located on the rear panel (shown below).

MOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (5)

  1. STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals, respectively.
  2. STEP 2: To keep the DC wires from pulling loose, use a screwdriver to tighten the wire-clamp screws.

Wiring the Relay Contact

Each switch has one relay output.

FAULT:
The relay contact of the 2-pin terminal block connector is used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains closed.

USB Connection

The switch has two USB ports, one type B USB-serial console port and one type A USB host port, located on the front panel. Use a USB cable (type A male to type B male) to connect the USB-serial console port to your PC’s COM port, and install the USB driver (available in the software CD) on the PC. You may then use a console terminal program, such as Moxa’s PComm Terminal Emulator, to access the console configuration utility of the switch.
Use Moxa’s USB Automatic Backup Configurator ABC-02-USB to connect to the USB host port to backup and restore configuration files, auto-load configuration files, upgrade firmware, and backup system log files.MOXA-IKS-6700A-IKS-6728A-8PoE-Series-Industrial-Rackmount-Switch-FIG- (6)

The Reset Button

Depress the Reset button for five continuous seconds to load the factory default settings. Use a pointed object, such as a straightened paper clip or toothpick, to depress the Reset button. When you do so, the STATE LED will start to blink about once per second. Continue to depress the STATE LED until it begins blinking more rapidly; this indicates that the button has been depressed for five seconds and you can release the Reset button to load factory default settings.

NOTE DO NOT power off the switch when loading default settings

LED Indicators

The front panel of the IKS switch contains several LED indicators. The function of each LED is described in the table below.

LED Color State Description
System LEDs
 

PWR1*

 

AMBER

On Power is being supplied to the main

module’s power input PWR1

Off Power is not being supplied to the main module’s power input PWR1
 

PWR2*

 

AMBER

On Power is being supplied to the main

module’s power input PWR2

Off Power is not being supplied to the main

module’s power input PWR2

 

EPS1

 

AMBER

On Power is being supplied to the PoE+ power input EPS1
Off Power is not being supplied to the PoE+

power input EPS1

 

EPS2

 

AMBER

On Power is being supplied to the PoE+

power input EPS2

Off Power is not being supplied to the PoE+ power input EPS2
*: On the IKS-6700A/IKS-6728A-8PoE-4GTXSFP-48-48-T model, both

PWR1 and PWR2 LED will be “On” with a single power input. This is because both internal power units are operating as redundant secondary power with the single input.

LED Color State Description
 

 

 

 

STATE

 

 

 

 

GREEN

On System has passed self-diagnosis test on boot-up and is ready to run
 

 

 

Blinking

1.  System is undergoing the self- diagnosis test

2.  Blink continuously when pressing the reset button 5 seconds to reset to factory default

3.  Blink slowly when an ABC-02

automatic backup device is detected

RED On System failed self-diagnosis on boot-up
 

FAULT

 

RED

On System is in the event of failure, or is

under quick inspection

Off System is in normal operation
 

 

 

 

MSTR/ HEAD

 

 

 

 

 

GREEN

 

On

When the IKS-6700A/IKS-6728A-8PoE

is set as the Master of the Turbo Ring, or as the Head of the Turbo Chain

 

 

Blinking

The IKS-6700A/IKS-6728A-8PoE has

become the Ring Master of the Turbo Ring, or the Head of the Turbo Chain, after the Turbo Ring or the Turbo Chain is down

 

Off

The IKS-6700A/IKS-6728A-8PoE is not

the Master of this Turbo Ring or is set as a Member of the Turbo Chain

 

 

CPLR/ TAIL

 

 

 

GREEN

 

On

When the IKS-6700A/IKS-6728A-8PoE

coupling function is enabled to form a back-up path, or when it’s set as the Tail of the Turbo Chain

Blinking When the Turbo Chain is down
Off When this IKS-6700A/IKS-6728A-8PoE

switch disables the coupling function

When the system is importing/exporting data from or to an ABC-02- USB automatic backup device, the FAULT, MSTR/HEAD, and CPLR/TAIL LEDs will blink in sequence.
Port Status LEDs
G1 to G4 (1000M TP

ports, left LED on the

connector)

 

 

GREEN

On The corresponding port’s 1000 Mbps link

is active

Blinking Data is being transmitted at 1000 Mbps
Off The corresponding port’s 1000 Mbps link is inactive
G1 to G4 (10/100M

TP ports, right LED on the

connector)

 

 

GREEN

On The corresponding port’s 10/100 Mbps

link is active

Blinking Data is being transmitted at 10/100 Mbps
Off The corresponding port’s 10/100 Mbps link is inactive
 

G1 to G4 (100/1000M

Fiber Optic ports)

 

 

GREEN

On Fiber optic port’s 1000 Mbps link is

active

Blinking Data is being transmitted at 1000 Mbps
Off Fiber Optic port’s 1000 Mbps link is

inactive

AMBER On Fiber optic port’s 100 Mbps link is active
Blinking Data is being transmitted at 100 Mbps
LED Color State Description
    Off Fiber Optic port’s 100 Mbps link is inactive
 

 

 

P1 to P8 (10/100M

TP ports)

 

 

GREEN

On The corresponding port’s 100 Mbps link

is active

Blinking Data is being transmitted at 100 Mbps
Off The corresponding port’s 100 Mbps link

is inactive

 

 

AMBER

On The corresponding port’s 10 Mbps link is

active

Blinking Data is being transmitted at 10 Mbps
Off The corresponding port’s 10 Mbps link is inactive
 

 

 

 

 

 

 

 

 

P1 to P8 (PoE+ ports)

 

 

 

GREEN

On The corresponding port is connected to an IEEE 802.3at power device
 

Blinking

Over current or short circuit on the power device with IEEE 802.3at

standard

 

Off

The corresponding port is not connected to a power device with IEEE 802.3at

standard

 

 

 

 

 

AMBER

 

On

The corresponding port is connected to a power device with IEEE 802.3af standard
 

 

Blinking

Once per second:

Detecting error on the power device

Twice per second:

Over current or short circuit on the power device with IEEE 802.3af standard

 

Off

The corresponding port is not connected to a power device with IEEE 802.3af standard

Specifications

Technology
Standards IEEE 802.3af/at for Power-over-Ethernet IEEE 802.3 for 10BaseT

IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X)

IEEE 802.3z for 1000BaseX IEEE 802.3x for Flow Control

IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP

IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging

IEEE 802.1p for Class of Service IEEE 802.1X for Authentication

IEEE 802.3ad for Port Trunk with LACP

Protocols IGMP v1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP

Server/Client, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, DHCP

Option 66/67/82, EtherNet/IP, Modbus/TCP, PROFINET, LLDP, IEEE 1588 PTP V2, IPv6, NTP

Server/Client

MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control IEEE 802.3x flow control, back pressure flow control
Interface
Fast Ethernet 8-port 10/100Base T(X) or PoE+ 10/100BaseT(X) 2 modular slots for any 8-, or 6-port Interface Modules with 10/100BaseT(X), 100BaseFX (SC/ST

connector), 100Base SFP, or PoE+ 10/100BaseT(X)

Gigabit Ethernet 2- or 4-port 10/100/1000BaseT(X) or 100/1000Base

SFP

Console Port USB-serial console (Type B connector)
LED Indicators PWR1, PWR2, EPS1, EPS2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL
Alarm Contact 1 relay output with current carrying capacity of 2 A

@ 30 VDC

Power Requirements
Input Voltage IKS-6700A Series:

24 VDC models: 24 VDC

48 VDC models: 48 VDC HV models: 110/220 VAC IKS-6728A-8PoE Series:

48 VDC models: 48 VDC (46 to 57 VDC) for switch and PoE system

HV models: 110/220 VAC for switch system, 48 VDC for PoE system (53 to 57 VDC is recommended for

PoE+ devices)

Input Current Max. 1.1 A @ 24 VDC

Max. 0.6 A @ 48 VDC

Max. 0.46 A @ 110 VAC

Max. 0.31 A @ 220 VAC

Note: These are the input current ratings for the device with the maximum number of modules installed.

Inrush Current IKS-6700A Series:

Max. 46.2 A @ 24 VDC (0.1 – 1 ms)

Max. 37.4 A @ 48 VDC (0.1 – 1 ms)

Max. 13.1 A @ 110 VAC (0.1 – 1 ms)

Max. 27.5 A @ 220 VAC (0.1 – 1 ms) IKS-6728A-8PoE Series:

Max. 46.2 A @ 24 VDC (0.1 – 1 ms)

Max. 37.4 A @ 48 VDC (0.1 – 1 ms)

Max. 23.8 A @ 54 VDC (0.1 – 1 ms)

Max. 15.4 A @ 110 VAC (0.1 – 1 ms)

Max. 31.7 A @ 220 VAC (0.1 – 1 ms)

Power Consumption (Max.) Max. 26.4 W @ 24 VDC

Max. 28.8 W @ 48 VDC

Max. 29.28 W @ 110 VAC

Max. 31.92 W @ 220 VAC

Note: These are the power consumption ratings for the device with the maximum number of modules installed.

Total PoE Power Budget IKS-6728A-PoE Series: Max. 720 W @ 48 VDC
Overload Current

Protection

Present
Reverse Polarity

Protection

Present
Physical Characteristics
Housing IP30 protection
Dimensions 440 x 44 x 280 mm (17.32 x 1.37 x 11.02 in)
Weight IKS-6700A/IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 4250 g

IKS-6700A/IKS-6728A-8PoE-4GTXSFP-HV-T: 4150 g IKS-6700A/IKS-6728A-8PoE-4GTXSFP-48-48-T: 4250 g

IKS-6700A/IKS-6728A-8PoE-4GTXSFP-48-T: 4150 g

IKS-6726A/6728A series: 4100 g

Installation 19’’ rack mounting
Environmental Limits
Operating Temp. -40 to 75°C (-40 to 167°F)
Storage Temp. -40 to 85°C (-40 to 185°F)
Ambient Relative

Humidity

5 to 95% (non-condensing)
Standards and Certifications
Safety UL 60950-1, EN 60950-1
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV

IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m

IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV

IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV

IEC 61000-4-6 CS: Signal: 10 V

IEC 61000-4-8

Note: For better conductive radiation immunity, STP cable is recommended.
Maritime DNV, GL, LR, ABS, NK (for IKS-6700A Series)
Rail Traffic EN 50121-4
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty

Rack Mounting Instructions

  1. Elevated Operating Ambient: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
    NOTE In order to ensure reliable operations, please make sure the operating temp. of the environment does not exceed the spec. When mounting an IKS rack-mounted switch with other operating units in a cabinet without forced ventilation, it is recommended that 1U of space is reserved between each rack-mounted switch and/or device.
  2. Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
  3. Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
  4. Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  5. Reliable Grounding: Reliable grounding of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

NOTE The rackmount ears can be equipped on the front or rear of  Moxa IKS-6700A/IKS-6728-8PoE switch.

Restricted Access Locations 

  • This equipment is intended to be used in Restricted
    Access Locations, such as a computer room, with access limited to SERVICE PERSONAL or USERS who have been instructed on how to handle the metal chassis of equipment that is so hot that special protection may be needed before touching it. The location should only be accessible with a key or through a security identity system.
  • External metal parts of this equipment are extremely hot!! Before touching the equipment, you must take special precautions to protect your hands and body from serious injury.

Patent
http://www.moxa.com/doc/operations/Moxa_Patent_Marking.pdf

ATTENTION 

  1. To protect against the risk of fire, only replace the fuse with one that has the same type and rating.
  2. It is recommended to incorporate a readily accessible disconnect device into the building installation wiring. Importantly, ensure the power supply is disconnected before performing any maintenance.
  3. This equipment is designed to connect the earthed conductor of the D.C supply circuit to the equipment’s’ earthing conductor.
  4. It is recommended to keep the PoE network indoors when using Information Technology Equipment.