VASCO-logo

VASCO ER090 Design Radiator

VASCO-ER090-Design-Radiator-product

Product Information

Specifications

  • Model: ER090
  • Intended Use: Heating indoor spaces and drying textiles washed in water
  • Not Suitable for: Sitting, climbing, or as a ladder

Product Usage Instructions

Allowed Usage

The radiator is designed for heating indoor spaces and drying textiles washed in water. Any other use is not in accordance with the regulations and therefore not allowed.

Safety Precautions

CAUTION: Risk of burns when venting with hot water spraying out! Protect your hands.

Additional Electric Heating

  • Keep the separate manual for the heating element handy.
  • Ensure the radiator is always completely filled.

Mounting

The radiator should only be installed by a certified installer. When adding additional electric heating, specific tasks should be carried out by an electrician.

Safety Precautions

  • Read and follow the user and installation manual carefully before mounting/starting up.
  • Leave the manual with the end user after installation.
  • Adhere to safety instructions in the separate manual of the electrical set.

Operating Conditions

Various operating conditions and precautions need to be followed for safe installation and use:

  • Follow construction procedures for building projects.
  • Maintain water quality standards to prevent damage in heating systems.
  • Observe application limits in moist areas.
  • Store and transport radiators only in protective packaging.

FAQ

  • Q: Can the radiator be used for purposes other than heating indoor spaces and drying textiles?
    • A: No, the radiator should only be used for its intended purposes as specified in the manual for safety reasons.

Instructions for installation and use of design radiators ER090

Instructions for use

Permissible use

The radiator may only be used for heating interior spaces and for drying textiles washed in water. Any other use is contrary to the intended purpose and therefore not permissible.

Misuse

The radiator is not usable as a seating accommodation, climbing or lifting support.

Safety instructions

Warning

Risk of burns!

The radiator’s surface can heat up to 110 °C (230 °F).

  • Be careful when touching the radiator

Caution

Risk of burns due to squirting hot water

when evacuating air!

  •  Protect your hands

Additional electric operation

  • Observe separate instructions for the heating element.
  • Ensure that the radiator is always completely filled with water and has been bled, so that the radiator heats up properly.
  • Do not operate the hot water heater and the heating element simultaneously.
  • Ensure that the return is open.
  • Close the thermostatic head.

Maintenance

Vent the radiator after commissioning and following lengthy interruptions of operation.

Cleaning

Use only mild, non-abrasive cleansing agents.

Complaint

Contact your local dealer.

Installation and repairs

Have the installation and repairs performed by a specialized tradesman so that your claims under warranty are not forfeited?

Disposal

Recycle or dispose of disused radiators, including accessories, properly. Observe local regulations

Installation

The radiator may only be installed by a specialized tradesman.
For additional electric operations, the following activities may be performed only by an electrical specialist (in Germany, according to BFVA3):

  • Installation and connection of the electric set
  • Connection of the heating element to the electric set

Safety instructions

  • Read these instructions for installation and use thoroughly prior to installation/commissioning.
  • After installation, pass the instructions on to the end user.
  • Observe the safety directions in the separate electric set instructions.

Danger

Life-threatening situation

  • Check the condition of the supply lines (electricity, gas, water).
  • Do not drill into any lines.

Warning

Risk of injury!

  • Note the radiator’s weight.
  • At 25 kg and above, work with lifting equipment or several persons.

Warning

Personal injury and material damage! 

  • Take the radiator’s filled weight and possible additional loads into consideration.
  • Check fasteners for applicability and tailor them to the structural situation.
  • Special requirements, e.g. for public buildings (schools or the like), must be taken into account.

Operating conditions

  • Observe operating conditions for water heating installations according to DIN 18380 “VOB German Construction Contract Procedures”.
  • Observe water’s condition according to VDI [Association of German Engineers] 2035 “Prevention of damage in water heating installations”.
  • Observe limitations of use in damp locations according to DIN 55900 “Coatings for radiators”.
  • Use radiators only in closed heating systems.
  • Store and transport the radiator only in the protective packaging

For additional electric operation: 

  • Select heating element heat output according to the radiator type (see current sales documents).
  • When installing in rooms with bath or shower facilities: take into account protective areas according to national installation standards (in Germany DIN VDE 0100-701). Also follow all local regulations.
    • Note: The manufacturer does not approve the installation of products in protective area 1.

Recommendation according to IEC standard 60335-2-43: To prevent any risk to small children, install the radiator so that the bottommost cross tubes are situated at least 600 mm above the floor.

  • Ensure that when the valve in the supply flow is closed, the water in the radiator can expand up to the expansion vessel.
  • When installing a valve in the return, ensure that the valve can only be actuated with a tool to prevent authorized blocking.

Technical features

  • Operating pressure: max. 10 bar
  • Test pressure: 1.3 x operating pressure
  • Flow: available on the right or the left
  • Flow temperature:
    • Hot water up to 110 °C (230 °F)
    • for additional electric operation up to 80 °C (176 °F)

Directions for installation

  • Information for when connecting from top
    • When delivered, an insert pipe is installed in the return right. The insert pipe must be replaced for the left return. If the radiator is connected at the bottom, then the insert pipe must be removed. It is possible to install an electric heating rod in the side opposite the insert pipe. It is only possible to install a heating rod from the bottom.

Number of attachment points

  • Requirement class 2 according to VDI 6036 only permissible if the recommended guideline values for displacement and withdrawal forces in usual connection situations are observed.
  • If necessary, mount an additional bracket and liftout / shift restraint device (refer to manufacturer’s documentation). Please also observe the installation instructions of the dealer
  • The number of attachment points was determined and checked on vertically cored lightweight brick T14.
  • Observe the dimension and position of the connections.
  • Refer to the respective instructions or manufacturer’s documentation for the number and arrangement of separate fastening elements.

For additional electric operation: 

  • Observe the electric set installation instructions.
  • Ensure that a correctly installed mounting box or wall socket (230 V, 16 A fuse) is available within the reach of the cable.

The electrical connection at the wall must be freely accessible and must not project out to the surface of the radiator or the control unit. The radiator must not be attached directly beneath a wall socket

For installation in a one-pipe heater: 

  • Use connection fitting with integrated, adjustable bypass.

Commissioning

  • Fill and vent the radiator. Risk of scalding!!
  • Check the radiator and connections for leaks.

Dimensions and weights

VASCO-ER090-Design-Radiator-fig1 VASCO-ER090-Design-Radiator-fig2

  • Check the location of the supply lines.
  • Check the bearing surface for load-carrying capacity.
  • Check the suitability of the screws and anchors.

VASCO-ER090-Design-Radiator-fig3

Legend

  • Air vent
  • Weight (empty)
  • Spacing of drilled hole to lower
  • edge connecting sleeve
  • Space between drill holes
  • Hub distance
  • Item No.
  • Return
  • Water content
  • Flow
  • suitable screw fittings

Installation

VASCO-ER090-Design-Radiator-fig4 VASCO-ER090-Design-Radiator-fig5 VASCO-ER090-Design-Radiator-fig6

VASCO-ER090-Design-Radiator-fig7

 

 

 

  • For minimum spacing and dimensions, see Fig. AVASCO-ER090-Design-Radiator-fig8
  • Do not drill into any of the lines. Danger to life!VASCO-ER090-Design-Radiator-fig9 VASCO-ER090-Design-Radiator-fig10
  • Ensure uniform hanging depth.VASCO-ER090-Design-Radiator-fig11,.,.,..,
  • If necessary, shorten the spacer at the rupture point.VASCO-ER090-Design-Radiator-fig12VASCO-ER090-Design-Radiator-fig13 VASCO-ER090-Design-Radiator-fig14 VASCO-ER090-Design-Radiator-fig15 VASCO-ER090-Design-Radiator-fig16
  • Check whether the bolt is supported securely and the locking screw is situated in the top part.VASCO-ER090-Design-Radiator-fig17 VASCO-ER090-Design-Radiator-fig18
  • Connect the radiator with commercially available fittings upstream.
  • Fill and vent the radiator. Risk of scalding!
  • Check radiator and connections for leaks

VASCO-ER090-Design-Radiator-fig19

Documents / Resources

VASCO ER090 Design Radiator [pdf] Instruction Manual
ER090 Design Radiator, ER090, Design Radiator, Radiator

References

Leave a comment

Your email address will not be published. Required fields are marked *