SAFETY WARNING

– This appliance has been designed for domestic use in the household environment. Never use the appliance for professional or industrial use.
– This appliance can be operated by children over the age of 8 and by people with impaired physical, sensorial, and mental faculties or without the necessary experience and competence only if properly supervised and if they had been duly provided with the necessary instructions concerning the safe use of the appliance and informed of the potential associated risks and warnings.
– Children shall not be allowed to play with the appliance.
– Safety and warning instructions specified in the user manual shall be strictly followed.
– Caution: Failure to use screws and fixing devices according to instructions specified in this manual, may result in electrical risk.
– The appliance shall not be used by persons (children included) with impaired physical, sensorial, and mental faculties or without the necessary experience and competence unless they have been properly supervised and instructed.
– Cleaning the appliance carefully after each use is very important, as failure to perform regular cleaning may result in fire risk.
– Make sure all the appliance components are not damaged. In such a case, do not carry out installation and contact a qualified technical assistance center.
– Qualified installers shall make any necessary carpentry and installation works in full compliance with directives in force.
– Do not connect the appliance to the electrical network during installation.
– Disconnect the appliance from power supply before carrying out any cleaning or maintenance operation.
– Need to allow the disconnection of the appliance from the mains supply after the installation, through an accessible plug or main switch.
– Steam cleaner should not be used.
– Do not use harsh abrasives or sharp metal scrapers to clean glass since they can scratch the surface, which can cause the glass to break.
– CAUTION: Ensure that the appliance is disconnected (OFF) before replacing the lamp to avoid the possibility of electric shock.
– Do not remove the protective plastic from the hood until it is completely installed, if this plastic is not present in areas that could have a risk of damage during installation. This will avoid damage to the outside of the appliance, something that will not be covered by the guarantee.

WARNINGS FOR ELECTRICAL CONNECTION

– Electrical connections shall be approved by a qualified electrician before using the appliance.
– Electrical connection shall be performed by just one qualified electrician, who will be responsible for proper electrical connection of the appliance to power supply.
– Before connecting the appliance to the electrical network, check if voltage, frequency, and power values specified in the rating label of the appliance are compatible with home power supply and socket.
– The power cord shall be connected to an omni polar magneto-thermal breaker with a switch-contact gap of at least 3 mm.
– In case the power cord is damaged, it shall be replaced either by the manufacturer or the technical assistance service or by specialized personnel.
– The power cord shall not enter contact with surfaces whose temperature exceeds 50° C once the appliance has been installed.

WARNINGS FOR OPERATION

– Ventilation must be provided conveniently in the room if a range hood and appliances powered by gas or other fuel used simultaneously.
– If the hood is used simultaneously with appliances that burn gas or other fuels, the room must have sufficient ventilation (this warning is not applicable for hoods installed in the filtering version).
– Comply with any local standard in force on air exhaust operations.
– If the appliance is used in the recirculation mode, make sure the exhaust dust is in good conditions in case it was not used for long.
– It is not allowed to cook food over open flames (flambe) under the hood.
– Never leave pots unattended when the hob is on: oil contained in the pot might overheat and burn. Fire risk is quite higher when oil is used.
– Grease filters proper maintenance and accurate cleaning are extremely important.
– Clean the hood and the other surfaces regularly in order to avoid any fire risk.
– CAUTION: when the hob is on, accessible parts of the hood might become hot.
– Connection of the exhaust device to exhaust ducts or channels and pipes for room ventilation is not allowed.
– Extracted air shall not be conveyed into a hot air circulation duct.
– Air shall not be discharged into a chimney flue used for fumes from household appliances powered by gas or other fuels (this is not applicable in case of hoods working in the recirculation mode).
– Adequately ventilate the room when a cooker hood and other
– Maximum negative pressure in the room shall not exceed 4 Pa (4×10-5 bar).
– The room where the hood is being installed shall be provided with an air intake whose capacity shall be greater than the hood exhaust device one. It is strictly forbidden to place the limbs or any other part of the human body, as well as cooking objects or other objects, near the extractable unit of the hood (if your appliance is equipped with it).
– Range hoods and other cooking fume extractors may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of a range hood or other cooking fume extractor, the operation of open flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.

For a safe use of the product and to know all the features and performances:

– Carefully read this instruction manual for use before installation and commissioning.
– Attention especially to safety warnings!
– The appliance may only be used as described in this instruction manual.
– Keep the instruction manual.
– If you give the appliance to a third party, also give the instruction manual.

Dear Customer,
thank you for choosing us!

Congratulations for having purchased your new kitchen hood.

In order to use the appliance safely and to better know all its features and performances:
– Read this instructions manual carefully before installing and switching the appliance on.
– Special attention shall be paid to safety warnings!
– The appliance shall only be used according to instructions given in this user manual.
– Keep this instruction manual for further reference.
– In case the appliance is given to third party, the instructions manual shall also be given.

GENERAL INFORMATION

When exchanging information with the appliance MANUFACTURER, please refer to the serial number and identification data specified in the rating label.
This appliance has been designed, tested, and manufactured in full compliance with any relevant standards on:

  • Safety: CEI/EN 60335-1; CEI/EN 60335-2-31;
  • Performance: CEI/EN 61591; CEI/EN 60704-1; CEI/EN 60704-2-13; EN 50564; CEI 62301.
    EMC: EN 55014-1; EN 55014-2; CEI/EN 61000-3-2; CEI/EN 61000-3-3.

Recommendations for proper use of the appliance aimed at reducing environmental impact: when you start cooking, switch the hood on at minimum speed and switch it off only few minutes after you finished cooking. Increase the hood speed only in case of large amounts of vapours and fumes, and use the booster function only when necessary. Clean the grease filter only, when necessary, in order to keep its efficiency over time. Use a piping system having the maximum diameter specified in this manual, in order to increase efficiency and reduce noise levels.

Disposal Icon 35The symbol on the appliance or on its documentation indicates that this product shall not be treated as household waste, but it shall be handed over to a specific collection point for the recycling of electrical and electronic equipment. Proper disposal of this appliance will help reduce raw materials consumption and environmental pollution. For more detailed information about recycling of this appliance, please contact your local city office, your household waste disposal service, or the shop where you purchased the appliance.

Spare Parts

Use original spare parts only.
Replace components before they are worn out. Perform regular maintenance checks, as detailed in the “MAINTENANCE” section.

Warranty

In order to enjoy the MANUFACTURER’S warranty, users shall strictly follow all the instructions specified in this manual, they shall:
– use the hood only for its intended purposes;
– perform continuous and scrupulous maintenance operations;
– allow the use of the hood only to persons with proven skills and know-how.
Failure to comply with the instructions contained in this manual will immediately void the manufacturer’s warranty.

INSTALLATION INSTRUCTIONS

– Installation and electrical connection operations shall be performed according to these instructions and by qualified and specialized personnel.
– Wear protective gloves before and during installation.
– Check that no accessory material provided with the appliance (manuals, accessories, etc) is placed inside the hood: in such a case remove and keep them.
– Figures shown in this installation manual might also refer to different aesthetics of the appliance: in any case use, installation and maintenance instructions remains the same.

Minimum installation safety distance

The distance between an electric hob and the lower part of the hood must be at least 550 mm, while between a gas hob and the lower part of the hood must be minimum 650 mm.
The recommended installation distance between the ceiling hood and the hob is between 1300 and 1500mm, while the maximum distance is 2000mm.
This hood is designed to be installed on the ceiling both in the ASPIRATING version with evacuation of fumes to the outside and in the FILTERING version by purchasing the appropriate kit.

TEKA DHT 96340 Ceiling Hood - a1 TEKA DHT 96340 Ceiling Hood - a2 TEKA DHT 96340 Ceiling Hood - a3

CONTROL INSTRUCTION

TEKA DHT 96340 Ceiling Hood - b1

The remote control comes factory-set with the kitchen hood: should communication between the remote control and the hood be interrupted, please perform the following procedure:

  • Disconnect the hood from power supply;
  • Wait for a few seconds and restore electrical connection, then within 10 seconds press keys “P1” and PT simultaneously for about 3 seconds.

The remote control will work properly.

FUNCTIONS

P0: MOTOR ON / OFF key.
If selected with the engine off, the display shows a zero “0” for about 1 second.
P1: button to decrease the motor speed, if the hood is in 1st speed it switches off the motor.
P2: button to increase the motor speed, if the hood is off it turns on the 1st speed, pressing a second time activates the 2nd speed, pressing a third time activates the 3rd speed, pressing a fourth time activates the 4th speed (intensive speed). The duration of the intensive speeds is 6 minutes at the end of which the electronics automatically returns to 3rd speed. The numbers of the selected speeds appear on the display (“1”, “2”, “3”, “4”).
PL: LIGHTS ON / OFF key
PC: FRESH AIR ON/OFF key

Fresh Air Activation / Deactivation: By pressing the “PC” button once you will enter on the Fresh Air/Clean Air function menu. Then, pressing “PC” button again for a long time with the hood off Fresh Air function will be activated (it will display a “C” on the screen). This function allows the engine to be switched on at 1st speed for 10 minutes followed by 50 minutes of stand-by. This option remains active during a period of 24 hours. To deactivate the Fresh Air function, press the “PC” or “P0” key again. While the function is active, both with the engine running and in stand-by, the hood LED will flash every 5 seconds.
Clean Air Activation / Deactivation: By pressing the “PC” button once you will enter on the Fresh Air/Clean Air function menu. Then, pressing the “PC” once the Clean Air function will be activated (a “C” appears on the display).
When this function is activated, the motor is set at maximum speed for about 6 minutes, at the end of the 6 minutes the motor will switch off automatically.
To deactivate this function, press the “PC” key or the “P0” key.
Note: this function can only be activated with the hood on and has priority over all the other active motor functions.

PT: TIMER button (a “t” and the engine speed appear on the display)
The timer performs a 15 minutes countdown and can only be activated with the engine running. The duration of 15 minutes does not change even if the speeds are changed during the countdown. At the end of the 15 minutes the engine stops.
PD: Display

Note: To save battery energy, the display remains active for approximately 4 seconds after which it turns off. To view the active functions, select any key and the display turns back on.

HOOD LED INDICATION

In the body of the hood there is a LED which indicates the operating status of the motor depending on the speed according to this criterion:

Engine OFF: LED off;
1st speed motor, Blue LED color;
2nd Speed Motor Green LED colour;
3rd Speed Motor Yellow LED colour;
Motor 4th Speed Red LED color (Flashes intermittently for 1 second for 6 minutes and then returns to 3rd speed).

When the timer is activated, the LED of the relevant color, depending on the set speed, flashes intermittently for 1 second; after 15 minutes, at non-intensive speeds, the engine switches off and not the lighting. As regards the intensive speeds, when the timer is activated, it remains at the set speed for the first 6 minutes and then ends the remaining 9 minutes at the 3rd speed.

In the Clean Air function the light blue LED remains steady, the engine switches to 4th speed and after 6 minutes the engine switches off and not the lighting.

In the Fresh Air function the blue LED flashes intermittently for 5 seconds, with the hood off the motor turns on at 1st speed for 10 minutes and then remains off for 50 minutes and so on until the function is deactivated.

Metal grease filter cleaning signal
After 30 hours of operation, the Green LED will start flashing for 20 seconds indicating to clean the filters. To reset the filters, with the hood off, press the “P0” key for 3 seconds while the LED is flashing.

Long-life or ceramic filter cleaning signal
After 120 hours of operation, the Red LED will start flashing for 20 seconds indicating to clean the filters. To reset the filters, with the hood off, press the “P0” key for 3 seconds while the LED is flashing.

Each time a button on the remote control is pressed, the hood will emit an acoustic signal to confirm the reception of the signal.

MAINTENANCE

WARNING! Before any cleaning or maintenance operation, remove the hood power supply by removing the cable or disconnecting the main switch in the home. Cleaning and ordinary maintenance must not be done by children without supervision.

Cleaning

The product should frequently be cleaned both internally and externally using a cloth dampened with lukewarm water and neutral non-abrasive liquid detergent.

The metallic grease filters

It has the task of retaining the fat particles from the cooking fumes and preserving the motor of the aspirator, so it is subject to clogging in variable times in relation to the use of the appliance. The filters can be washed in the dishwasher with short wash cycles and at low temperatures, at the latest every 2 months to avoid the risk of fire. After some washes the filter could change color, due to dishwasher salts and detergents. The color change does not affect the functionality of the grease filter.

Ceramic filters

They have the task of retaining odors and purifying the air that is returned to the environment. The ceramic filters can be cleaned in the oven at a temperature of 180/200 ° C for about 45/60 minutes. It is recommendable to replace the ceramic filters every 5 years to assure the best odor elimination.

Lighting

The hood is equipped with lighting based on high efficiency LED technology, low power consumption and very high durability under normal conditions of use.
For replacement, contact the service department.

THE COMPANY MANUFACTURER cannot be held responsible for any damage caused by an improper installation or use of this appliance.

TROUBLESHOOTING
PROBLEM POSSIBLE CAUSES

SOLUTIONS

The lights of the cooker hood do not turn on  Lamp connector is disconnected Hook up the lamp connector as shown on page 5, Fig. 5 of the manual.
On/off switch is in position 0 Set the on/off switch to position 1 as shown on page 4, Picture 4 of the instruction manual.
No electricity Check the Lighting Driver.
Remote control is not synchronised Synchronise the remote control as described in the instruction manual from page 20.
The motor does not work Disconnected connector Hook up the motor connector as shown on page 6, Picture 7 of the instruction manual.
No electricity Check the motor driver.
Electricity arrives but the motor does not work Replace the motor.
The Remote Control is not working Low remote control battery Replace battery as shown on page 12, Picture 20 of the instruction manual.
Make sure that the battery is inserted with the correct polarity.
Remote control is not synchronised with the hood Synchronise the remote control as described in the instruction manual from page 20.
On/off switch is in position 0 Set the on/off switch to position 1 as shown on page 4, Picture 4 of the instruction manual. 
Hood is not working No electricity Check the power cable.
Remote control is not synchronised with the hood Synchronise the remote control as described in the user manual from page 20.
Electrical system problems Check the power supply on the electronic board.
On/off switch is in position 0 Set the on/off switch to position 1 as shown on page 4, Picture 4 of the instruction manual.
Hood aspirates little air Soiled aluminium filters Remove the filters as shown on page 11, Picture 17 of the operating manual and wash the filters. 
Green LED flashes for 20 seconds Metal grease filter cleaning indicator Reset the filters when the hood is turned off pressing the “P0” button on the remote control for 3 seconds while the LED flashes as shown on page 22 of the instruction manual.
Red LED flashes for 20 seconds Long-life or ceramic filter cleaning indicator Reset the filters when the the hood is turned off pressing the button “P0” on the remote control for 3 seconds while the LED flashes as shown on page 22 of the user manual.