UBIBOT-LOGO

UBIBOT NR1 Wi-Fi Temperature SensorUBIBOT-NR1-Wi-Fi-Temperature-Sensor-PRODCUT -

This user manual serves as general guidance for all types of UBIBOT9 Smart Network Relay. Some features, which are marked with asterisk, are available only for specific versions. Please refer to the related instructions according to the version you purchased.

PACKAGE LIST

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-1

Note: Please tighten the antenna before use.

INTRODUCTION

  1. Basic Features IntroductionUBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-2

Device Operations

  • Switch On/Off: After the power is plugged in/unplugged, the device will Switch On/Off automatically.
  • Setup Mode: With the device switched on, press and hold the function button for about 5 seconds until the device status indicator flashes red and green alternately. Release at this time to enter the setup mode.
  • Send data: Under the power-on state, press the function button once, and the green device status indicator will flash, then connect to the network and send data.
  • Reset to Default Settings: Under the power-on state, press and hold the function button for about 15 seconds until the red device status indicator blinks, then release the button to restore factory settings.

Electrical Wiring

1nterface

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-3

  • CD COM-
  • Digital Input l
  • Digital Input 2
  • Digital Input 3
  • Digital lnput4
  • COM+
  • Output of DC 12V
  • NO node of Relay l
  • COM node of Relay l
  • NC node of Relay 1
  • NO node of Relay 2
  • COM node of Relay 2
  • NC node of Relay 2
  • NO node of Relay 3
  • COM node of Relay 3
  • NC node of Relay3
  • NO node of Relay 4
  • COM node of Relay 4
  • NC node of Relay 4

Device Operations

  1. Passive switch (dry contact): passive contact signal, with two states (off/on), no polarity between the two contacts, such as various types of switches, buttons, etc.UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-4
  2. Active switches (wet contact, DCS-12V): signals with voltage (high/low level, pulse), with two states (power/no power), the polarity between the two contacts, such as liquid level detection, smoke detection, PLC output, infrared detection, flow detection, etc.
    Active switchUBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-5

Relay Output Wiring

  1. Low load wiring: Non-resistive load current less than 3A or resistive load less than SA.UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-6
  2. AC 220V load wiring: The external load is the AC 220V power supply.UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-7
  3. AC 380V (with null line) Load wiring: The external load is AC 380V with null line.UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-8

WARNING:  If necessary, insert an AC contactor/intermediate relay between the product and the external load.

  1. Rated load voltage> DC 30V
  2. Non-resistive load current> 3A
  3. Load-rated voltage > AC 250V
  4. Resistive load current> SA

DEVICE SETUP OPTIONS

Option 1: Using a Mobile App
Download the App from www.ubibot.com/setup, or search for ‘Ubibot’ on the AppStore or Google Play.

INFO: We recommend you try to use the PC Tools in case the App setup fails, because the failure may be due to mobile phone incompatibility. The PC Tools is much easier to operate and suitable for both Mac and Windows.

Option 2: Using PC Tools

  • Download the tool from www.ubibot.com/setup.
  • This tool is a desktop app for device setup. It is also helpful in checking setup failure reasons, MAC addresses, and offline charts. You can also use it to export offline data stored in the device’s internal memory.

SETUP USING THE APP FOR WiFi CONNECTION
Launch the App and log in. On the home page, tap”+” to start adding your device. Then please follow the in-app instructions to complete the setup. You can also view the demonstration video at www.ubibot.com/­setup for step-by-step guidance.

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-9

Via our app and web console (http://console.ubibot.com). you can view the readings as well as config­ure your device, such as creating alert rules, setting data sync interval, etc. You can find and watch the demonstration videos at www.ubibot.com/setup.

SETUP USING THE APP FOR MOBILE NETWORK

  • Before you set up the device on mobile data, please check the APN information of the SIM card used for the UbiBot device.
  • An APN (Access Point Name} provides the details your device needs to connect to mobile data through your network operator. APN details differ by network and you will need to get these from your network operator.
  • With the device off, insert the SIM card as indicated in the picture. Launch the app and log in. Tap the”+” to start setting up the device. Please follow the in-app instructions to complete the setup process. Please note, that the setup will fail if you don’t have data allowance.

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-10

SETUP USING THE APP FOR ETHERNET CABLE CONNECTION

  • STEP 1. Connect the device to the power supply and plug the Ethernet cable.
  • STEP 2. Launch the app and log in. On the home page, tap”+” to start adding your device. Then, please follow the in-app instructions to complete the setup. You can also view the demonstration video at www.ubibot.com/setup for step-by-step guidance.

SETUP USING PC TOOLS

  • STEP 1. Launch the App and log in. With the device switched on, use the Type-C USB cable provided to connect your device to the computer. The PC Tools will automatically scan and recognize the product ID and enter the device page.
  • STEP 2. Click “Network” on the left menu bar. There, you can set up the device on WiFi for all the models. For the SIM or Ethernet cable setup, please click on the corresponding button to continue.

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-11

RS485 COMMUNICATION

The default mode is the RS485 communication slave mode. If the external sensor collection time is set in the platform, the master mode for data collection will be activated and the slave mode will be turned off automati­cally. If the device has been networked, the setting parameters are set by the platform.
For more details, please contact your local distributor or refer to the online documentation.

DEVICE USE

Working Mode

  1. CD Online control mode: you can remotely control relay operations through the UbiBot cloud platform, including opening/closing the relay, the overall synchronization or independent single-point control, timing, and cycle setup, delaying tasks, or defining trigger conditions through early warning rules and automation control.
  2. Pules on/off mode: Pulse ON, i.e., when the relay is in the closed state, the relay can be set to disconnect for a period (set parameter*0.ls) and then close automatically. Pulse OFF, i.e., when the relay is discon­nected, the relay can be set to close for a period (set parameter*0.ls) and then disconnect automatically.
  3. Local linkage mode: The device has 4 optocoupler inputs, which can be directly linked with the relay. It means that when the optocoupler input signal is effective, the corresponding relay will absorb/disconnect/no action; when the optocoupler input signal is canceled, the corresponding relay will disconnect/absorb/no action. The corresponding relationship between the optocoupler input and the relay’s absorption/disconnec­tion/non-activation can be set through the PC tools or the UbiBot platform.
  4. Offline control mode: The NRl device supports the Modbus RTU protocol, allowing for offline control of 4-channel relays through an RS485 connection to a computer.
  5. Safety interlock mode: The device supports a safety interlock setting. if any of the relays set for safety interlocking is turned on, the other relays will be turned off.

UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-12UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-13

FAQ

Device network configuration failure reasons

  • Please check if the WiFi account password is correct;
  • Please check whether the router is working properly and the network connection is normal;
  • Please make sure the device has entered the WiFi configuration mode;
  • Please check whether the WiFi band is 2.4GHz and the channel is between 1 ~ 13;
  • Please check the WiFi channel width is set to 20MHz or auto mode;
  • WiFi security type: NRl supports OPEN, WEP, and WPA/WPA2-personal;
  • Poor signal strength, please check the WiFi or cell phone data traffic signal strength.

Ethernet network* configuration failure reasons

  • Please check whether the network cable is properly connected to the equipment;
  • whether the network cable is intact;
  • whether the connected network can access the Internet;

If the above points are not abnormal, and you still cannot activate the device, you need to check whether the network environment allows DHCP (automatic IP allocation) devices to access the network; or re-scan the device QR code, select Ethernet access (advanced mode), and follow the APP prompts to manually assign IP to the device.

Reasons for failure to send device data

  • Check whether the router is working properly;
  • If using the mobile data traffic provided by the SIM card* inside the device, you need to check whether the SIM card* is activated; if the SIM card* is activated, check whether the power supply of the device is normal; also check whether the amount of the mobile data traffic provided by the device SIM card* is sufficient for the data transfer.

Can the device be used in a network-free environment?

  • The device can still work without a network and can be controlled in real time through the switch input or RS485 interface.
  • For more frequently asked questions, please visit www.ubibot.com and go to the “Community and Documen­tation” page.

TECHNICAL SUPPORT

The UbiBot team is glad to hear your voice about our products and services.
For any questions or suggestions, please feel free to create a ticket in the UbiBot app. Our customer services representatives respond within 24 hours and often in less than an hour. You can also contact the local distribu­tors in your contry for localized service. Please go to our website to view their contacts.

PRODUCT MAINTENANCE INSTRUCTIONS

  • UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-14Please always follow the instructions contained in this manual.
  • UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-15Always mount the device on a stable surface.
  • UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-16Keep away from acidic, oxidizing, flammable, or explosive substances.
  • UBIBOT-NR1-Wi-Fi-Temperature-Sensor-FIG-17When handling the device, avoid using excessive force and never use sharp instruments to try and open it.

WARRANTY

WARRANTY INFORMATION

  1. The warranty period for this product is one year from the date of purchase. The buyer is required to submit a valid proof of purchase. During the warranty period, free repair will be provided for any failure caused by the quality of the product under normal use. The mailing cost of the returned product is the responsibility of the sender (one way).
  2. The following cases are not covered by the warranty:
    CD the product is out of warranty;
  3. product failure or damage caused by incorrect or improper operation not under the product use instructions, configuration instructions, and product maintenance instructions;  accidental or man-made damage to the product, such as exceeding the temperature and humidity range of the equipment, water-caused damage, including natural water, such as water vapor, etc., fall, abnormal physical force, deformation, cable breakage, etc.;
    • damage due to natural wear and tear, consumption and aging, etc. (including shells, cables, etc.);
    • failure or damage caused by unauthorized dismantling of the product without permission;
    • failure or damage caused by force majeure, such as earthquake, fire, lightning strike, tsunami, etc.;
    • other failure or damage caused unrelated to product design, technology, manufacturing or quality.